FCC ID SWX-M5P
Long-Range Carrier Class 5 GHz MIMO Bridging Solution
by Ubiquiti Networks, Inc.
Grantee Code: SWX Product Code: M5P
Latest application date: 2011-06-30
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5728-5847 MHz | Original Equipment | 2011-06-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2011-06-30 | PDF 3.9 MB |
| Internal Photos | Internal Photos | 2011-06-30 | PDF 2 MB |
| External Photos | External Photos | 2011-06-30 | PDF 472.9 KB |
| Label | ID Label/Location Info | 2011-06-30 | PDF 575 KB |
| Test Setup Photos | Test Setup Photos | 2011-06-30 | PDF 701.3 KB |
| Manufacturer Attestation Letter Rev. 1 | Test Report | 2011-06-30 | PDF 70.1 KB |
| Revised Test Report | Test Report | 2011-06-30 | PDF 6 MB |
| Test Report | Test Report | 2011-06-30 | PDF 4.8 MB |
| Test Lab Attestation Letter | Cover Letter(s) | 2011-06-30 | PDF 113.2 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2011-06-30 | PDF 62.1 KB |
| Antenna Datasheet | RF Exposure Info | 2011-06-30 | PDF 258.5 KB |
| MPE | RF Exposure Info | 2011-06-30 | PDF 272.5 KB |
Application Information
| Application ID | 3f+HdEunTIOCUgCSdI4lkg== |
|---|---|
| Final Action Date | 2011-06-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0012268215 |
| Model | -M5P |
| Frequency Range | 5728-5847 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Long-Range Carrier Class 5 GHz MIMO Bridging Solution |
| Responsible Party | Michael Taylor, Compliance Manager, compliance@ubnt.com |
| Technical Contact | Robert Pera, Ubiquiti Networks, Inc., Robert@ubnt.com |
| Test Firm | Robert Frier, MET Laboratories, Incorporated, rfrier@metlabs.com |
| TCB Email | tcbinfo@metlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is conducted and aggregate conducted for MIMO operation. This is a 2x2 MIMO operating in a configuration as described in this filing. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 157 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 3f+HdEunTIOCUgCSdI4lkg== | 2011-06-30 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 3f+HdEunTIOCUgCSdI4lkg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MET Laboratories, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230-3432 |
Date of Grant: 06/30/2011 Application Dated: 06/30/2011 |
| Ubiquiti Networks, Inc. |
| 2580 Orchard Parkway |
| San Jose, CA 95131 |
| Attention: Michael Taylor , Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SWX-M5P |
| Name of Grantee: | Ubiquiti Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Long-Range Carrier Class 5 GHz MIMO Bridging Solution |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 5735.0 - 5840.0 | 0.251 | |||
| 15C | 5747.0 - 5828.0 | 0.196 | |||
| MO | 15C | 5728.0 - 5847.0 | 0.272 | ||
| MO | 15C | 5730.0 - 5845.0 | 0.264 | ||
| MO | 15C | 5731.0 - 5844.0 | 0.325 | ||
| MO | 15C | 5735.0 - 5840.0 | 0.419 | ||
| MO | 15C | 5740.0 - 5835.0 | 0.395 | ||
| MO | 15C | 5747.0 - 5828.0 | 0.347 |
| Power Output listed is conducted and aggregate conducted for MIMO operation. This is a 2x2 MIMO operating in a configuration as described in this filing. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 157 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application 3f+HdEunTIOCUgCSdI4lkg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ubiquiti Networks, Inc. 2580 Orchard Parkway San Jose, CA 95131 United States |
Date of Grant: 06/30/2011 Application Dated: 06/30/2011 |
| Attention: Michael Taylor , Compliance Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SWX-M5P |
| Name of Grantee: | Ubiquiti Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | Long-Range Carrier Class 5 GHz MIMO Bridging Solution |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 5735.0 - 5840.0 | 0.251 | |||
| 15C | 5747.0 - 5828.0 | 0.196 | |||
| MO | 15C | 5728.0 - 5847.0 | 0.272 | ||
| MO | 15C | 5730.0 - 5845.0 | 0.264 | ||
| MO | 15C | 5731.0 - 5844.0 | 0.325 | ||
| MO | 15C | 5735.0 - 5840.0 | 0.419 | ||
| MO | 15C | 5740.0 - 5835.0 | 0.395 | ||
| MO | 15C | 5747.0 - 5828.0 | 0.347 |
| Power Output listed is conducted and aggregate conducted for MIMO operation. This is a 2x2 MIMO operating in a configuration as described in this filing. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 157 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |