FCC ID SWX-UAPACPRO

Digital Transmission Radio

by Ubiquiti Inc.

Grantee Code: SWX   Product Code: UAPACPRO
Latest application date: 2020-09-28

FCC ID Device Details

FCC IDSWX-UAPACPRO
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSWX
Product CodeUAPACPRO
Applicant BusinessUbiquiti Inc. 🇺🇸
Related Domains ui.com
Equipment ClassDigital Transmission Radio
Test FirmUnified Compliance Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2020-09-28
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2020-09-28
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2020-08-11
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2020-08-11
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2017-02-21
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2017-02-21
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2016-06-01
2412-2462 MHzOriginal Equipment2015-09-11
5180-5240 MHzOriginal Equipment2015-09-11

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2017-02-21PDF 3.4 MB
User ManualUsers Manual2015-10-26PDF 2.4 MB
Int photoInternal Photos2015-10-26PDF 396 KB
Ext photoExternal Photos2015-10-26PDF 277.4 KB
ID LabelID Label/Location Info2015-09-11PDF 604.8 KB
Test Setup PhotosTest Setup Photos2017-02-21PDF 531.6 KB
DFS Test Setup PhotosTest Setup Photos2016-07-16PDF 273.6 KB
Test Setup PhotoTest Setup Photos2016-07-16PDF 171.7 KB
Test setup photoTest Setup Photos2015-10-26PDF 391.9 KB
Test setup photoTest Setup Photos2015-10-26PDF 410.3 KB
Test photos Metadata onlyTest Setup Photos2015-09-11PDF 1.6 MB
Test Rpt DTSTest Report2020-09-28PDF 1.1 MB
Test Rpt NIITest Report2020-09-28PDF 1.3 MB
Test ReportTest Report2017-02-21PDF 1.1 MB
Test Report DFSTest Report2016-06-01PDF 3.9 MB
Test Report NIITest Report2016-06-01PDF 1.6 MB
Test ReportTest Report2015-09-11PDF 2.3 MB
Test ReportTest Report2015-09-11PDF 1.6 MB
Test ReportTest ReportPDF 759.9 KB
C2PC Cover LetterCover Letter(s)2020-09-28PDF 206.7 KB
C2PC LetterCover Letter(s)2017-02-21PDF 20.3 KB
POACover Letter(s)2017-02-21PDF 80.3 KB
Professional InstallationCover Letter(s)2017-02-21PDF 19.2 KB
Class II Permissive Change LetterCover Letter(s)2016-06-01PDF 27.4 KB
Confidentiality Request LetterCover Letter(s)2016-06-01PDF 42.2 KB
DTS-UNII Declaraction letterCover Letter(s)2016-06-01PDF 59.2 KB
PoA LetterCover Letter(s)2016-06-01PDF 325.8 KB
Product Certification Representative Auth LetterCover Letter(s)2016-06-01PDF 29.7 KB
03_P.O.A for ATLCover Letter(s)2015-09-11PDF 90.6 KB
Confidential request letterCover Letter(s)2015-09-11PDF 164.6 KB
Confidentiality Request LetterCover Letter(s)2015-09-11PDF 164.6 KB
POACover Letter(s)2015-09-11PDF 107.6 KB
POA for ATLCover Letter(s)2015-09-11PDF 90.6 KB
WiFi ch 12 13Cover Letter(s)2015-09-11PDF 88.7 KB
C2PC Cover LetterCover Letter(s)PDF 133.2 KB
MPERF Exposure Info2017-02-21PDF 213.7 KB
MPE CalculationRF Exposure Info2016-06-01PDF 479.2 KB
MPE ReportRF Exposure Info2015-09-11PDF 264 KB
Block diagram Metadata onlyBlock DiagramPDF 17.6 KB
SCH Metadata onlySchematicsPDF 570.5 KB
OpDes Metadata onlyOperational DescriptionPDF 21.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 12.9 KB
SOFTWARE SECURITY DESCRIPTION Metadata onlyOperational DescriptionPDF 570.3 KB
Software Security Declaration Metadata onlyOperational DescriptionPDF 264.3 KB

Application Information

Application ID5t/WxZaxxheLhrYPGMSyXA==
Final Action Date2020-09-28
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0012268215
ModelUAPACPRO
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionDigital Transmission Radio
Responsible PartyMark Feil, Compliance Director, compliance@ui.com , 385-293-3532
Test FirmAlex Macon, Unified Compliance Laboratory, ucl@ui.com , 385-200-1617
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Applications

Application IDDatePurpose
5t/WxZaxxheLhrYPGMSyXA==2020-09-28Class II permissive change or modification of presently authorized equipment
/6aOYduFPQDX9uCDqsbMAw==2020-09-28Class II permissive change or modification of presently authorized equipment
5q3iC2tP4+euSNvrm+QruA==2020-08-11Class II permissive change or modification of presently authorized equipment
2N8Z4zRImyTN2lTyBXcigA==2020-08-11Class II permissive change or modification of presently authorized equipment
nhIbHanqiriU1OFmjm4rFA==2017-02-21Class II permissive change or modification of presently authorized equipment
TZYzkYRTG1NTq9AdakC/9w==2017-02-21Class II permissive change or modification of presently authorized equipment
Qijuaxz5j6kh4J2rGVyx7Q==2016-06-01Class II permissive change or modification of presently authorized equipment
6nOYxqLu7JjalV7yp+BAlw==2015-09-11Original Equipment
3TT6cMLkFV1S24WjTISSUg==2015-09-11Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.101000015CCC, MO
2412-2462 MHz0.101000015CCC
5180-5240 MHz0.14915E38, CC, MO
5180-5240 MHz0.14915ECC, MO
5260-5320 MHz0.18415ECC, MO, ND
5260-5320 MHz0.18415ECC, MO
5260-5320 MHz0.18415E38, CC, MO, ND
5500-5700 MHz0.18715ECC, MO, ND
5500-5700 MHz0.18715ECC, MO
5500-5700 MHz0.18715E38, CC, MO, ND
5745-5825 MHz0.18515E38, CC, MO
5745-5825 MHz0.18515ECC, MO

Grants

TCB Grant - Application TZYzkYRTG1NTq9AdakC/9w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 02/21/2017

Application Dated: 02/20/2017
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.149  
38 CC MO ND 15E 5260.0  -  5320.0 0.184  
38 CC MO ND 15E 5500.0  -  5700.0 0.187  
38 CC MO 15E 5745.0  -  5825.0 0.185  

Class II Permissive Change: The equipment is to add to outdoor fixed type with the professional installation. Maximum conducted power of 5150 ~ 5250 MHz band is below 17.78 dBm for outdoor used to meet maximum e.i.r.p. at any elevation angle above 30 degrees as measured from the horizon must not exceed 125 mW (21 dBm).

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application TZYzkYRTG1NTq9AdakC/9w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 02/21/2017

Application Dated: 02/20/2017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.149  
38 CC MO ND 15E 5260.0  -  5320.0 0.184  
38 CC MO ND 15E 5500.0  -  5700.0 0.187  
38 CC MO 15E 5745.0  -  5825.0 0.185  

Class II Permissive Change: The equipment is to add to outdoor fixed type with the professional installation. Maximum conducted power of 5150 ~ 5250 MHz band is below 17.78 dBm for outdoor used to meet maximum e.i.r.p. at any elevation angle above 30 degrees as measured from the horizon must not exceed 125 mW (21 dBm).

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application Qijuaxz5j6kh4J2rGVyx7Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 06/01/2016

Application Dated: 03/22/2016
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.149  
38 CC MO ND 15E 5260.0  -  5320.0 0.184  
38 CC MO ND 15E 5500.0  -  5700.0 0.187  
38 CC MO 15E 5745.0  -  5825.0 0.185  

CIIPC to add DFS band.

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application Qijuaxz5j6kh4J2rGVyx7Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 06/01/2016

Application Dated: 03/22/2016
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.149  
38 CC MO ND 15E 5260.0  -  5320.0 0.184  
38 CC MO ND 15E 5500.0  -  5700.0 0.187  
38 CC MO 15E 5745.0  -  5825.0 0.185  

CIIPC to add DFS band.

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application nhIbHanqiriU1OFmjm4rFA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 02/21/2017

Application Dated: 02/20/2017
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.101  

Class II Permissive Change: The equipment is to add to outdoor fixed type with the professional installation

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application nhIbHanqiriU1OFmjm4rFA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 02/21/2017

Application Dated: 02/20/2017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.101  

Class II Permissive Change: The equipment is to add to outdoor fixed type with the professional installation

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 6nOYxqLu7JjalV7yp+BAlw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/11/2015

Application Dated: 09/10/2015
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.101  

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 6nOYxqLu7JjalV7yp+BAlw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 09/11/2015

Application Dated: 09/10/2015
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.101  

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 5t/WxZaxxheLhrYPGMSyXA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/28/2020

Application Dated: 09/24/2020
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Digital Transmission Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.149  
CC MO 15E 5260.0  -  5320.0 0.184  
CC MO 15E 5500.0  -  5700.0 0.187  
CC MO 15E 5745.0  -  5825.0 0.185  

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 5t/WxZaxxheLhrYPGMSyXA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 09/28/2020

Application Dated: 09/24/2020
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Digital Transmission Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.149  
CC MO 15E 5260.0  -  5320.0 0.184  
CC MO 15E 5500.0  -  5700.0 0.187  
CC MO 15E 5745.0  -  5825.0 0.185  

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 5q3iC2tP4+euSNvrm+QruA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 01/05/2022

Application Dated: 06/16/2020
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Digital Transmission Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.149  
CC MO ND 15E 5260.0  -  5320.0 0.184  
CC MO ND 15E 5500.0  -  5700.0 0.187  
CC MO 15E 5745.0  -  5825.0 0.185  

Power listed is maximum combined conducted output power. Professional installation is required. Device operates with specific antennas in MIMO configurations as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, and 80 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application 5q3iC2tP4+euSNvrm+QruA==

This application currently is not in final status.

TCB Grant - Application 3TT6cMLkFV1S24WjTISSUg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/11/2015

Application Dated: 09/10/2015
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.149  
38 CC MO 15E 5745.0  -  5825.0 0.185  

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures

38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 3TT6cMLkFV1S24WjTISSUg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 09/11/2015

Application Dated: 09/10/2015
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
38 CC MO 15E 5180.0  -  5240.0 0.149  
38 CC MO 15E 5745.0  -  5825.0 0.185  

Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 3x3 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures


38: This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 2N8Z4zRImyTN2lTyBXcigA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 01/05/2022

Application Dated: 06/16/2020
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Digital Transmission Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.101  

Power listed is maximum combined conducted output power. Professional installation is required. Device operates with specific antennas in MIMO configurations as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 and 40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application 2N8Z4zRImyTN2lTyBXcigA==

This application currently is not in final status.

TCB Grant - Application /6aOYduFPQDX9uCDqsbMAw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 09/28/2020

Application Dated: 09/24/2020
Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Digital Transmission Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.101  

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.
Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application /6aOYduFPQDX9uCDqsbMAw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ubiquiti Inc.
685 Third Avenue
New York, NY 10017
United States
  Date of Grant: 09/28/2020

Application Dated: 09/24/2020
 
Attention: Mark Feil , Compliance Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SWX-UAPACPRO
Name of Grantee:  Ubiquiti Inc.
Equipment Class: Digital Transmission System
Notes: Digital Transmission Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.101  

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Power listed is the maximum combined conducted output power. Device is 3x3 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: