FCC ID SX3-HRT300

Handheld Rugged Terminal

by PRADOTEC CORPORATION SDH. BHD. (807780-P)

Grantee Code: SX3   Product Code: HRT300
Latest application date: 2013-07-31

FCC ID Device Details

FCC IDSX3-HRT300
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSX3
Product CodeHRT300
Applicant BusinessPRADOTEC CORPORATION SDH. BHD. (807780-P) 🇲🇾
Related Domains pradotec.com.my
Equipment ClassHandheld Rugged Terminal
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2013-07-31
824.2-848.8 MHzOriginal Equipment2013-07-31
2412-2462 MHzOriginal Equipment2013-07-31

Exhibits

DocumentTypeAvailableFile
AddendumUsers Manual2013-07-31PDF 31.7 KB
ManualUsers Manual2013-07-31PDF 1.8 MB
IntInternal Photos2013-07-31PDF 1 MB
ExtExternal Photos2013-07-31PDF 155.4 KB
LabelID Label/Location Info2013-07-31PDF 65.7 KB
LocationID Label/Location Info2013-07-31PDF 35.6 KB
Test ReportSchematics2013-07-31PDF 1.9 MB
SetupTest Setup Photos2013-07-31PDF 88.3 KB
Test SetupTest Setup Photos2013-07-31PDF 88.3 KB
Part 22Test Report2013-07-31PDF 848.3 KB
Part 24Test Report2013-07-31PDF 620.6 KB
Test ReportTest Report2013-07-31PDF 1.9 MB
WiFiTest Report2013-07-31PDF 2 MB
AuthorizationCover Letter(s)2013-07-31PDF 59 KB
ConfidCover Letter(s)2013-07-31PDF 49.6 KB
DofCCover Letter(s)2013-07-31PDF 28.4 KB
SARRF Exposure Info2013-07-31PDF 3.8 MB

Application Information

Application IDuLQM2zQ/Fpkye4m8sQlmgA==
Final Action Date2013-07-31
Application PurposeOriginal Equipment
Applicant FRN0022634364
Model-HRT300
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionHandheld Rugged Terminal
Responsible PartyJerene Goh, Product Assurance Engineer, jerene.goh@pradotec.com.my , 014-2298810
Technical ContactMark Koop, Teleconformity, mark.koop@teleconformity.com , (31)848395876
Test FirmDaniel zhu, Shenzhen Anbotek Compliance Laboratory Limited, Daniel.zhu@anbotek.com , 86-755-26014771
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. This device may transmit simultaneously with other Licensed and Unlicensed transmitters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
uLQM2zQ/Fpkye4m8sQlmgA==2013-07-31Original Equipment
gMAEUkuAL5tUoSItqhVUfg==2013-07-31Original Equipment
O8cSoKGqwWYTwZNbEUAMSA==2013-07-31Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz0.8220.1ppm251KG7W22HBC
826.4-846.6 MHz0.0860.1ppm4M18F9W22HBC
1850.2-1909.8 MHz0.7160.1ppm249KG7W24EBC
2402-2480 MHz0.002100015CCC
2412-2462 MHz0.048900015CCC

Grants

TCB Grant - Application uLQM2zQ/Fpkye4m8sQlmgA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/31/2013

Application Dated: 07/30/2013
PRADOTEC CORPORATION SDH. BHD. (807780-P)
IRIS Smart Technology Complex,
Technology Park Malaysia,
Bukit Jalil, Kuala Lumpur, 57000
Malaysia
 
Attention: Jerene Goh , Product Assurance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SX3-HRT300
Name of Grantee:  PRADOTEC CORPORATION SDH. BHD. (807780-P)
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Handheld Rugged Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0021  

Power Output listed is Conducted. This device may transmit simultaneously with other Licensed and Unlicensed transmitters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application uLQM2zQ/Fpkye4m8sQlmgA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PRADOTEC CORPORATION SDH. BHD. (807780-P)
IRIS Smart Technology Complex, Technology Park Malaysia,
Bukit Jalil, Kuala Lumpur, 57000
Malaysia
  Date of Grant: 07/31/2013

Application Dated: 07/30/2013
 
Attention: Jerene Goh , Product Assurance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SX3-HRT300
Name of Grantee:  PRADOTEC CORPORATION SDH. BHD. (807780-P)
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Handheld Rugged Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0021  

Power Output listed is Conducted. This device may transmit simultaneously with other Licensed and Unlicensed transmitters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application O8cSoKGqwWYTwZNbEUAMSA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/31/2013

Application Dated: 07/30/2013
PRADOTEC CORPORATION SDH. BHD. (807780-P)
IRIS Smart Technology Complex,
Technology Park Malaysia,
Bukit Jalil, Kuala Lumpur, 57000
Malaysia
 
Attention: Jerene Goh , Product Assurance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SX3-HRT300
Name of Grantee:  PRADOTEC CORPORATION SDH. BHD. (807780-P)
Equipment Class: Digital Transmission System
Notes: Handheld Rugged Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0489  

Power Output listed is Conducted. This device is approved for simultaneous transmission with both Licensed and Unlicensed transmitters as identified within this filing. SAR compliance for body-worn operation is based upon a separation distance of 5mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metal components. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are: 0.34 W/kg; 0.50 W/kg;

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application O8cSoKGqwWYTwZNbEUAMSA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PRADOTEC CORPORATION SDH. BHD. (807780-P)
IRIS Smart Technology Complex, Technology Park Malaysia,
Bukit Jalil, Kuala Lumpur, 57000
Malaysia
  Date of Grant: 07/31/2013

Application Dated: 07/30/2013
 
Attention: Jerene Goh , Product Assurance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SX3-HRT300
Name of Grantee:  PRADOTEC CORPORATION SDH. BHD. (807780-P)
Equipment Class: Digital Transmission System
Notes: Handheld Rugged Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0489  

Power Output listed is Conducted. This device is approved for simultaneous transmission with both Licensed and Unlicensed transmitters as identified within this filing. SAR compliance for body-worn operation is based upon a separation distance of 5mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metal components. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are: 0.34 W/kg; 0.50 W/kg;


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application gMAEUkuAL5tUoSItqhVUfg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/31/2013

Application Dated: 07/30/2013
PRADOTEC CORPORATION SDH. BHD. (807780-P)
IRIS Smart Technology Complex,
Technology Park Malaysia,
Bukit Jalil, Kuala Lumpur, 57000
Malaysia
 
Attention: Jerene Goh , Product Assurance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SX3-HRT300
Name of Grantee:  PRADOTEC CORPORATION SDH. BHD. (807780-P)
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Handheld Rugged Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 0.822 0.1  PM 251KG7W
BC 22H 826.4  -  846.6 0.086 0.1  PM 4M18F9W
BC 24E 1850.2  -  1909.8 0.716 0.1  PM 249KG7W

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Power Output listed is ERP for Part 22, and EIRP for Part 24. SAR compliance for body-worn operation is based on a separation distance of 5mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are: 0.40 W/kg; 0.50 W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application gMAEUkuAL5tUoSItqhVUfg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PRADOTEC CORPORATION SDH. BHD. (807780-P)
IRIS Smart Technology Complex, Technology Park Malaysia,
Bukit Jalil, Kuala Lumpur, 57000
Malaysia
  Date of Grant: 07/31/2013

Application Dated: 07/30/2013
 
Attention: Jerene Goh , Product Assurance Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SX3-HRT300
Name of Grantee:  PRADOTEC CORPORATION SDH. BHD. (807780-P)
Equipment Class: PCS Licensed Transmitter worn on body
Notes: Handheld Rugged Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 0.822 0.1  PM 251KG7W
BC 22H 826.4  -  846.6 0.086 0.1  PM 4M18F9W
BC 24E 1850.2  -  1909.8 0.716 0.1  PM 249KG7W

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Power Output listed is ERP for Part 22, and EIRP for Part 24. SAR compliance for body-worn operation is based on a separation distance of 5mm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values for body-worn accessory and simultaneous transmission use conditions are: 0.40 W/kg; 0.50 W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: