FCC ID SXNLSNM-0002-X

Light Sensory Network Module

by Sensity Systems

Grantee Code: SXN   Product Code: LSNM0002X
Latest application date: 2014-08-08

FCC ID Device Details

FCC IDSXNLSNM-0002-X
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeSXN
Product CodeLSNM0002X
Applicant BusinessSensity Systems 🇺🇸
Related Domains sensity.com
Equipment ClassLight Sensory Network Module
Test FirmBay Area Compliance Laboratories Corporation

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2014-08-08
2412-2462 MHzOriginal Equipment2014-08-08

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2014-08-08PDF 747.6 KB
Int PhotosInternal Photos2014-08-08PDF 282.4 KB
Int PhotosInternal Photos2014-08-08PDF 282.5 KB
Ext PhotosExternal Photos2014-08-08PDF 439.6 KB
Ext PhotosExternal Photos2014-08-08PDF 439.5 KB
FCC ID LabelID Label/Location Info2014-08-08PDF 784.8 KB
Setup PhotosTest Setup Photos2014-08-08PDF 371.2 KB
Test Setup PhotosTest Setup Photos2014-08-08PDF 371.1 KB
Test ReportTest Report2014-08-08PDF 1.1 MB
Test Report DFSTest Report2014-08-08PDF 1.2 MB
Test Report NIITest Report2014-08-08PDF 1.5 MB
Confidentiality LetterCover Letter(s)2014-08-08PDF 28.5 KB
Module Approval LetterCover Letter(s)2014-08-08PDF 99.4 KB
POACover Letter(s)2014-08-08PDF 285.3 KB
RF ExposureRF Exposure Info2014-08-08PDF 20.3 KB
RF ExposureRF Exposure Info2014-08-08PDF 22.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 36.9 KB
Schematics Metadata onlySchematicsPDF 382.2 KB
Operation Description Metadata onlyOperational DescriptionPDF 300.2 KB

Application Information

Application IDllC+YfKc0mJrNVRKlhR0Vg==
Final Action Date2014-08-08
Application PurposeOriginal Equipment
Applicant FRN0022491799
ModelLSNM-0002-X
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionLight Sensory Network Module
Responsible PartyChristoher Hizer Hizer, HW Engineer, chizer@sensity.com , 408-841-4200
Test FirmLisa Tang, Bay Area Compliance Laboratories Corporation, lisat@baclcorp.com , 408-732-9162
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. Limited Modular approval. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.

Applications

Application IDDatePurpose
llC+YfKc0mJrNVRKlhR0Vg==2014-08-08Original Equipment
kZ5Fe+bVY3i2UCFB3e5C3g==2014-08-08Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.029000015CCC
5180-5240 MHz0.021715ECC
5260-5320 MHz0.028615ECC, ND
5500-5580 MHz0.020115ECC, ND
5660-5700 MHz0.020415ECC, ND

Grants

TCB Grant - Application llC+YfKc0mJrNVRKlhR0Vg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 08/08/2014

Application Dated: 08/08/2014
Sensity Systems
1237 Arques Avenue
Sunnyvale, CA 94085
 
Attention: Christoher Hizer Hizer , HW Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SXNLSNM-0002-X
Name of Grantee:  Sensity Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Light Sensory Network Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0217  
CC ND 15E 5260.0  -  5320.0 0.0286  
CC ND 15E 5500.0  -  5580.0 0.0201  
CC ND 15E 5660.0  -  5700.0 0.0204  

Output power listed is conducted. Limited Modular approval. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application llC+YfKc0mJrNVRKlhR0Vg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensity Systems
1237 Arques Avenue
Sunnyvale, CA 94085
United States
  Date of Grant: 08/08/2014

Application Dated: 08/08/2014
 
Attention: Christoher Hizer Hizer , HW Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SXNLSNM-0002-X
Name of Grantee:  Sensity Systems
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Light Sensory Network Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0217  
CC ND 15E 5260.0  -  5320.0 0.0286  
CC ND 15E 5500.0  -  5580.0 0.0201  
CC ND 15E 5660.0  -  5700.0 0.0204  

Output power listed is conducted. Limited Modular approval. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application kZ5Fe+bVY3i2UCFB3e5C3g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 08/08/2014

Application Dated: 08/08/2014
Sensity Systems
1237 Arques Avenue
Sunnyvale, CA 94085
 
Attention: Christoher Hizer Hizer , HW Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SXNLSNM-0002-X
Name of Grantee:  Sensity Systems
Equipment Class: Digital Transmission System
Notes: Light Sensory Network Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.029  

Output power listed is conducted. Limited Modular approval. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application kZ5Fe+bVY3i2UCFB3e5C3g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensity Systems
1237 Arques Avenue
Sunnyvale, CA 94085
United States
  Date of Grant: 08/08/2014

Application Dated: 08/08/2014
 
Attention: Christoher Hizer Hizer , HW Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  SXNLSNM-0002-X
Name of Grantee:  Sensity Systems
Equipment Class: Digital Transmission System
Notes: Light Sensory Network Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.029  

Output power listed is conducted. Limited Modular approval. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain maybe used with this transmitter. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: