FCC ID SZ30GD4010
GD4010 Smart Display Unit
by General Dynamics Canada Limited
Grantee Code: SZ3 Product Code: 0GD4010
Latest application date: 2013-05-28
FCC ID Device Details
| FCC ID | SZ30GD4010 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | SZ3 |
| Product Code | 0GD4010 |
| Applicant Business | General Dynamics Canada Limited 🇨🇦 |
| Related Domains | |
| Equipment Class | GD4010 Smart Display Unit |
| Test Firm | Sporton International Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Change in identification of presently authorized equipment. Original FCC ID: J9CGOBI3000 Grant Date: 07/29/2010 | 2013-05-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Ext photos | External Photos | 2013-05-28 | PDF 246.5 KB |
| Label | ID Label/Location Info | 2013-05-28 | PDF 246.5 KB |
| Change in ID request | Cover Letter(s) | 2013-05-28 | PDF 39.4 KB |
| PoA | Cover Letter(s) | 2013-05-28 | PDF 22.3 KB |
Application Information
| Application ID | t2CNnwfUdSL/ltpILjilIg== |
|---|---|
| Final Action Date | 2013-05-28 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: J9CGOBI3000 Grant Date: 07/29/2010 |
| Applicant FRN | 0022646400 |
| Model | 0GD4010 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | GD4010 Smart Display Unit |
| Responsible Party | James Beales, Commercial Officer, James.Beales@gdcanada.com |
| Test Firm | Alex Chen, Sporton International Inc., alex@sporton.com.tw |
| TCB Email | Brandhorst.dirk@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Limited Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is Conducted. The highest radiated power measured in specific configurations shown in filing is Part 22 1.584W ERP, Part 24 1.622W EIRP, Part 27 0.446W EIRP. This device contains 900/1800/2100 MHz and UTRA FDD I modes not operational in U.S. Territories. Limited Modular Approval for use as a module in only Mobile or Fixed exposure conditions. Antenna gain including cable loss must not exceed 4dBi in Cellular 800MHz band and 3.5dBi in PCS 1900MHz/AWS 1700MHz bands for purposes of 2.1043 and 2.1091. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and may be co-located and operated in conjunction with antennas or transmitters within the parameters documented in the Mobile RF exposure documentation of this filing. Compliance of this device in all final product configurations is the responsibility of the Grantee. Installation of this device into specific final products requires the submission of a Class II permissive change application, where appropriate; and containing data demonstrating compliance for SAR, MPE, spurious emissions, ERP/EIRP, and host/module authentication, or new application. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| t2CNnwfUdSL/ltpILjilIg== | 2013-05-28 | Change in identification of presently authorized equipment. Original FCC ID: J9CGOBI3000 Grant Date: 07/29/2010 |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 824.2-848.8 MHz | 2.01 | 2.5ppm | 248KGXW | 22H | BC |
| 824.2-848.8 MHz | 0.531 | 2.5ppm | 248KG7W | 22H | BC |
| 824.7-848.31 MHz | 0.29 | 2.5ppm | 1M28F9W | 22H | BC |
| 826.4-846.6 MHz | 0.281 | 2.5ppm | 4M19F9W | 22H | BC |
| 1712.4-1752.6 MHz | 0.287 | 2.5ppm | 4M15F9W | 27 | BC |
| 1850.2-1909.8 MHz | 1.199 | 2.5ppm | 250KGXW | 24E | BC |
| 1850.2-1909.8 MHz | 0.537 | 2.5ppm | 250KG7W | 24E | BC |
| 1851.25-1908.75 MHz | 0.287 | 2.5ppm | 1M28F9W | 24E | BC |
| 1852.4-1907.5 MHz | 0.294 | 2.5ppm | 4M19F9W | 24E | BC |
Grants
TCB Grant - Application t2CNnwfUdSL/ltpILjilIg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 05/28/2013 Application Dated: 05/28/2013 |
| General Dynamics Canada Limited |
| 1941 Robertson Road |
| Ottawa, K2H 5B7 Canada |
| Attention: James Beales , Commercial Officer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SZ30GD4010 |
| Name of Grantee: | General Dynamics Canada Limited |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GD4010 Smart Display Unit |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 2.01 | 2.5 PM | 248KGXW |
| BC | 22H | 824.2 - 848.8 | 0.531 | 2.5 PM | 248KG7W |
| BC | 22H | 826.4 - 846.6 | 0.281 | 2.5 PM | 4M19F9W |
| BC | 22H | 824.7 - 848.31 | 0.29 | 2.5 PM | 1M28F9W |
| BC | 24E | 1850.2 - 1909.8 | 1.199 | 2.5 PM | 250KGXW |
| BC | 24E | 1850.2 - 1909.8 | 0.537 | 2.5 PM | 250KG7W |
| BC | 24E | 1852.4 - 1907.5 | 0.294 | 2.5 PM | 4M19F9W |
| BC | 24E | 1851.25 - 1908.75 | 0.287 | 2.5 PM | 1M28F9W |
| BC | 27 | 1712.4 - 1752.6 | 0.287 | 2.5 PM | 4M15F9W |
| Power Output listed is Conducted. The highest radiated power measured in specific configurations shown in filing is Part 22 1.584W ERP, Part 24 1.622W EIRP, Part 27 0.446W EIRP. This device contains 900/1800/2100 MHz and UTRA FDD I modes not operational in U.S. Territories. Limited Modular Approval for use as a module in only Mobile or Fixed exposure conditions. Antenna gain including cable loss must not exceed 4dBi in Cellular 800MHz band and 3.5dBi in PCS 1900MHz/AWS 1700MHz bands for purposes of 2.1043 and 2.1091. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and may be co-located and operated in conjunction with antennas or transmitters within the parameters documented in the Mobile RF exposure documentation of this filing. Compliance of this device in all final product configurations is the responsibility of the Grantee. Installation of this device into specific final products requires the submission of a Class II permissive change application, where appropriate; and containing data demonstrating compliance for SAR, MPE, spurious emissions, ERP/EIRP, and host/module authentication, or new application. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application t2CNnwfUdSL/ltpILjilIg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
General Dynamics Canada Limited 1941 Robertson Road Ottawa, K2H 5B7 Canada |
Date of Grant: 05/28/2013 Application Dated: 05/28/2013 |
| Attention: James Beales , Commercial Officer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | SZ30GD4010 |
| Name of Grantee: | General Dynamics Canada Limited |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | GD4010 Smart Display Unit |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 2.01 | 2.5 PM | 248KGXW |
| BC | 22H | 824.2 - 848.8 | 0.531 | 2.5 PM | 248KG7W |
| BC | 22H | 826.4 - 846.6 | 0.281 | 2.5 PM | 4M19F9W |
| BC | 22H | 824.7 - 848.31 | 0.29 | 2.5 PM | 1M28F9W |
| BC | 24E | 1850.2 - 1909.8 | 1.199 | 2.5 PM | 250KGXW |
| BC | 24E | 1850.2 - 1909.8 | 0.537 | 2.5 PM | 250KG7W |
| BC | 24E | 1852.4 - 1907.5 | 0.294 | 2.5 PM | 4M19F9W |
| BC | 24E | 1851.25 - 1908.75 | 0.287 | 2.5 PM | 1M28F9W |
| BC | 27 | 1712.4 - 1752.6 | 0.287 | 2.5 PM | 4M15F9W |
| Power Output listed is Conducted. The highest radiated power measured in specific configurations shown in filing is Part 22 1.584W ERP, Part 24 1.622W EIRP, Part 27 0.446W EIRP. This device contains 900/1800/2100 MHz and UTRA FDD I modes not operational in U.S. Territories. Limited Modular Approval for use as a module in only Mobile or Fixed exposure conditions. Antenna gain including cable loss must not exceed 4dBi in Cellular 800MHz band and 3.5dBi in PCS 1900MHz/AWS 1700MHz bands for purposes of 2.1043 and 2.1091. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, and may be co-located and operated in conjunction with antennas or transmitters within the parameters documented in the Mobile RF exposure documentation of this filing. Compliance of this device in all final product configurations is the responsibility of the Grantee. Installation of this device into specific final products requires the submission of a Class II permissive change application, where appropriate; and containing data demonstrating compliance for SAR, MPE, spurious emissions, ERP/EIRP, and host/module authentication, or new application. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |