FCC ID T7HR4024
DECT 6.0 Wireless Relay Station
by RTX Hong Kong Ltd.
Grantee Code: T7H Product Code: R4024
Latest application date: 2018-03-27
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1921.536-1928.448 MHz | Class II permissive change or modification of presently authorized equipment | 2018-03-27 |
| 1921.536-1928.448 MHz | Original Equipment | 2012-04-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2012-04-16 | PDF 163.3 KB |
| user manual statements | Users Manual | 2012-04-16 | PDF 187.5 KB |
| internal photos | Internal Photos | 2012-04-16 | PDF 2.9 MB |
| external photos | External Photos | 2012-04-16 | PDF 1.3 MB |
| label and location | ID Label/Location Info | 2012-04-16 | PDF 311.8 KB |
| test setup photos | Test Setup Photos | 2012-04-16 | PDF 551.8 KB |
| Test Report | Test Report | 2018-03-27 | PDF 290.2 KB |
| Part 15D Declarations | Test Report | 2012-04-16 | PDF 849 KB |
| test report | Test Report | 2012-04-16 | PDF 909.6 KB |
| UTAM | Attestation Statements | 2012-04-16 | PDF 180.5 KB |
| Authorization letter | Cover Letter(s) | 2018-03-27 | PDF 116.8 KB |
| Permissive Change Declaration Letter | Cover Letter(s) | 2018-03-27 | PDF 12.6 KB |
| confidential letter | Cover Letter(s) | 2012-04-16 | PDF 94 KB |
| model difference letter | Cover Letter(s) | 2012-04-16 | PDF 100.3 KB |
| mpe calculation | RF Exposure Info | 2012-04-16 | PDF 21.9 KB |
Application Information
| Application ID | fo7ke8Z5Nk80lYMwbqiGLg== |
|---|---|
| Final Action Date | 2018-03-27 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0017849076 |
| Model | R4024 |
| Frequency Range | 1921.536-1928.448 MHz |
| Equipment Class | PUB - Part 15 Unlicensed PCS Base Station |
| Device Description | DECT 6.0 Wireless Relay Station |
| Responsible Party | Ted Chong, Engineering Manager, TED@rtx.hk |
| Test Firm | Well Wang, Bay Area Compliance Laboratories Corp. (Shenzhen), qa.sz@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | A3: Unlicensed Personal Communication System (PCS) devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change described in this filing. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This equipment is designed for use with industry standard transmitters. Interoperability tests were performed with companion devices base FCC ID: T7HX8660, handset FCC ID: T7HRTX8630. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| fo7ke8Z5Nk80lYMwbqiGLg== | 2018-03-27 | Class II permissive change or modification of presently authorized equipment |
| FWLieQZLvtTlsf3j4ephFQ== | 2012-04-16 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 1921.536-1928.448 MHz | 0.0980000 | 15D |
Grants
TCB Grant - Application FWLieQZLvtTlsf3j4ephFQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko Canada Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 04/16/2012 Application Dated: 04/12/2012 |
| RTX Hong Kong Ltd. |
| 8/F Corporation Square |
| 8 Lam Lok Street, Kowloon Bay |
| Kowloon Bay, Kowloon, Hong Kong |
| Attention: Ted Chong , Engineering Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | T7HR4024 |
| Name of Grantee: | RTX Hong Kong Ltd. |
| Equipment Class: | Part 15 Unlicensed PCS Base Station |
| Notes: | DECT 6.0 Wireless Relay Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.098 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This equipment is designed for use with industry standard transmitters. Interoperability tests were performed with companion devices base FCC ID: T7HX8660, handset FCC ID: T7HRTX8630. |
EAS Grant - Application FWLieQZLvtTlsf3j4ephFQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
RTX Hong Kong Ltd. 8/F Corporation Square 8 Lam Lok Street, Kowloon Bay Kowloon Bay, Kowloon, Hong Kong |
Date of Grant: 04/16/2012 Application Dated: 04/12/2012 |
| Attention: Ted Chong , Engineering Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | T7HR4024 |
| Name of Grantee: | RTX Hong Kong Ltd. |
| Equipment Class: | Part 15 Unlicensed PCS Base Station |
| Notes: | DECT 6.0 Wireless Relay Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.098 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This equipment is designed for use with industry standard transmitters. Interoperability tests were performed with companion devices base FCC ID: T7HX8660, handset FCC ID: T7HRTX8630. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 03/27/2018 Application Dated: 03/27/2018 |
| RTX Hong Kong Ltd. |
| 8/F Corporation Square |
| 8 Lam Lok Street, Kowloon Bay |
| Kowloon Bay, Kowloon, Hong Kong |
| Attention: Ted Chong , Engineering Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | T7HR4024 |
| Name of Grantee: | RTX Hong Kong Ltd. |
| Equipment Class: | Part 15 Unlicensed PCS Base Station |
| Notes: | DECT 6.0 Wireless Relay Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.098 |
| Class II Permissive Change described in this filing. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This equipment is designed for use with industry standard transmitters. Interoperability tests were performed with companion devices base FCC ID: T7HX8660, handset FCC ID: T7HRTX8630. |
EAS Grant - Application fo7ke8Z5Nk80lYMwbqiGLg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
RTX Hong Kong Ltd. 8/F Corporation Square 8 Lam Lok Street, Kowloon Bay Kowloon Bay, Kowloon, Hong Kong |
Date of Grant: 03/27/2018 Application Dated: 03/27/2018 |
| Attention: Ted Chong , Engineering Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | T7HR4024 |
| Name of Grantee: | RTX Hong Kong Ltd. |
| Equipment Class: | Part 15 Unlicensed PCS Base Station |
| Notes: | DECT 6.0 Wireless Relay Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.098 |
| Class II Permissive Change described in this filing. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. This equipment is designed for use with industry standard transmitters. Interoperability tests were performed with companion devices base FCC ID: T7HX8660, handset FCC ID: T7HRTX8630. |
| Mail To: |