FCC ID Device Details
| FCC ID | TA8AKRC161746-1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | TA8 |
| Product Code | AKRC1617461 |
| Applicant Business | Ericsson AB 🇸🇪 |
| Related Domains | |
| Equipment Class | Remote Radio Unit which supports LTE and NR |
| Test Firm | Intertek Testing Services Shanghai |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 3550-3700 MHz | Class II permissive change or modification of presently authorized equipment | 2023-10-03 |
| 3550-3700 MHz | Class II permissive change or modification of presently authorized equipment | 2023-09-07 |
| 3550-3700 MHz | Class II permissive change or modification of presently authorized equipment | 2023-06-06 |
| 3550-3700 MHz | Class II permissive change or modification of presently authorized equipment | 2022-02-18 |
| 3550-3700 MHz | Class II permissive change or modification of presently authorized equipment | 2020-04-14 |
| 3550-3700 MHz | Class II permissive change or modification of presently authorized equipment | 2020-02-06 |
| 3550-3700 MHz | Original Equipment | 2019-09-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos Blocked | External Photos | 2019-09-23 | PDF 216.2 KB |
| ID Label and Label Location Blocked | ID Label/Location Info | 2019-09-23 | PDF 108.6 KB |
| Test Setup Photos Blocked | Test Setup Photos | 2023-09-07 | PDF 645.8 KB |
| Test setup photos Blocked | Test Setup Photos | 2022-02-18 | PDF 847.8 KB |
| Test Setup Photos Blocked | Test Setup Photos | 2019-09-23 | PDF 329.4 KB |
| Exhibit 11 EMF Test Report Radio 4408 B48.pdf Blocked | RF Exposure Info | 2023-10-03 | PDF 449.9 KB |
| Test Report Blocked | Test Report | 2023-09-07 | PDF 3.8 MB |
| Test report Part3 Blocked | Test Report | 2023-06-06 | PDF 4.7 MB |
| Test report part1 Blocked | Test Report | 2023-06-06 | PDF 5.6 MB |
| Test report part2 Blocked | Test Report | 2023-06-06 | PDF 5.7 MB |
| Test report part4 Blocked | Test Report | 2023-06-06 | PDF 2.7 MB |
| Test report part1 Blocked | Test Report | 2022-02-18 | PDF 5.2 MB |
| CBRS Report Blocked | Test Report | 2019-09-23 | PDF 4.2 MB |
| Test Report 1 Blocked | Test Report | 2019-09-23 | PDF 5.5 MB |
| Test Report 2 Blocked | Test Report | 2019-09-23 | PDF 5.4 MB |
| Test Report 3 Blocked | Test Report | 2019-09-23 | PDF 5.5 MB |
| Test Report 4 Blocked | Test Report | 2019-09-23 | PDF 4.4 MB |
| Exhibit 2 FCC Authorization letter.pdf Blocked | Attestation Statements | 2023-10-03 | PDF 193.9 KB |
| Exhibit_2-_Applicant_Company_letter_2.911_5_i_ii.docx.pdf Blocked | Attestation Statements | 2023-10-03 | PDF 210.2 KB |
| Attestation Statement Blocked | Attestation Statements | 2023-09-07 | PDF 210.2 KB |
| CFR_47_2.911(d)(5) Blocked | Attestation Statements | 2023-06-06 | PDF 210.2 KB |
| CFR_47_2.911(d)(7) Blocked | Attestation Statements | 2023-06-06 | PDF 203.6 KB |
| Exhibit 13 Cover letter_FCC.pdf Blocked | Cover Letter(s) | 2023-10-03 | PDF 168.8 KB |
| Exhibit 13 Request for Confidentiality.pdf Blocked | Cover Letter(s) | 2023-10-03 | PDF 100 KB |
| Cover Letters Blocked | Cover Letter(s) | 2023-09-07 | PDF 496.8 KB |
| Application letter Blocked | Cover Letter(s) | 2023-06-06 | PDF 293.7 KB |
| Authorisation letter Blocked | Cover Letter(s) | 2023-06-06 | PDF 193.9 KB |
| Confidentiality letter Blocked | Cover Letter(s) | 2023-06-06 | PDF 100 KB |
| Authorisation letter Blocked | Cover Letter(s) | 2022-02-18 | PDF 366.9 KB |
| C2PC letter Blocked | Cover Letter(s) | 2022-02-18 | PDF 495 KB |
| Confidentiality request Blocked | Cover Letter(s) | 2022-02-18 | PDF 183 KB |
| Agents Letter Blocked | Cover Letter(s) | 2020-04-14 | PDF 313.3 KB |
| Antenna List Letter Blocked | Cover Letter(s) | 2020-04-14 | PDF 150.8 KB |
| C2PC Letter Blocked | Cover Letter(s) | 2020-04-14 | PDF 173.3 KB |
| Confidentiality Letter Blocked | Cover Letter(s) | 2020-04-14 | PDF 80.8 KB |
| Agent Letter Blocked | Cover Letter(s) | 2020-02-06 | PDF 313.3 KB |
| Antenna Information Blocked | Cover Letter(s) | 2020-02-06 | PDF 411.2 KB |
| Confidenitiality Letter Blocked | Cover Letter(s) | 2020-02-06 | PDF 88.2 KB |
| FCC Cover Letter Blocked | Cover Letter(s) | 2020-02-06 | PDF 485.5 KB |
| Antenna List Blocked | Cover Letter(s) | 2019-09-23 | PDF 113.4 KB |
| Confidentiality Letter Blocked | Cover Letter(s) | 2019-09-23 | PDF 78.8 KB |
| FCC Cover Letter Blocked | Cover Letter(s) | 2019-09-23 | PDF 72.3 KB |
| Limited Modular Approval Letter Blocked | Cover Letter(s) | 2019-09-23 | PDF 77.9 KB |
| RF Exposure info Blocked | RF Exposure Info | 2023-09-07 | PDF 2.6 MB |
| RF exposure report Blocked | RF Exposure Info | 2023-06-06 | PDF 451.6 KB |
| MPE report Blocked | RF Exposure Info | 2022-02-18 | PDF 451.6 KB |
| User Manual I Metadata only | Users Manual | PDF 149.2 KB | |
| User Manual II Metadata only | Users Manual | PDF 485 KB | |
| User Manual III Metadata only | Users Manual | PDF 2.4 MB | |
| User manual Part1 Metadata only | Users Manual | PDF 2.1 MB | |
| User manual part2 Metadata only | Users Manual | PDF 4.5 MB | |
| Internal Photos Metadata only | Internal Photos | PDF 222.8 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 186.4 KB | |
| Schematics Metadata only | Schematics | PDF 1.1 MB | |
| Antenna information Metadata only | Operational Description | PDF 5 MB | |
| Operating Description I Metadata only | Operational Description | PDF 5.7 MB | |
| Operating Description II Metadata only | Operational Description | PDF 324.9 KB | |
| Operational Description/Antenna Information Metadata only | Operational Description | PDF 411.2 KB | |
| Technical description Metadata only | Operational Description | PDF 264.1 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 175 KB |
Application Information
| Application ID | 0pbDZR/1O4DxTltR8Himxw== |
|---|---|
| Final Action Date | 2023-10-03 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0013476155 |
| Model | AKRC161746-1 |
| Frequency Range | 3550-3700 MHz |
| Equipment Class | CBD - Citizens Band Category A and B Devices |
| Device Description | Remote Radio Unit which supports LTE and NR |
| Responsible Party | Peter Moberg, Head of PEU Radio, peter.a.moberg@ericsson.com |
| Test Firm | Leah Xu, Intertek Testing Services Shanghai, leah.xu@intertek.com |
| TCB Email | stephen.milliken@tuvsud.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Limited Single Modular Approval |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive change to support additional external antenna max average Gain 6.7dBi, Limited Single Modular Approval. The power output listed is the manufacturer Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 0pbDZR/1O4DxTltR8Himxw== | 2023-10-03 | Class II permissive change or modification of presently authorized equipment |
| eXsC8XfO2EUHlKjNLNOIoQ== | 2023-09-07 | Class II permissive change or modification of presently authorized equipment |
| AMQJDfLRCC9dXfPU+qXj5Q== | 2023-06-06 | Class II permissive change or modification of presently authorized equipment |
| 7OK4v1XDrlH+abC4/EIYHQ== | 2022-02-18 | Class II permissive change or modification of presently authorized equipment |
| xuCsyU56uDN2kSetp9ZXig== | 2020-04-14 | Class II permissive change or modification of presently authorized equipment |
| yawvI3Ei2zAUMBHn1BfmgQ== | 2020-02-06 | Class II permissive change or modification of presently authorized equipment |
| ggYhCl548FqJua4jg8ogFQ== | 2019-09-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 3550-3700 MHz | 350.5 | 0.05ppm | 70M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 90M0F9W | 96 | MO |
| 3550-3700 MHz | 5 | 0.05ppm | 70M0F9W | 96 | MO |
| 3550-3700 MHz | 50 | 0.05ppm | 10M0F9W | 96 | EP, MO |
| 3550-3700 MHz | 354.6 | 0.05ppm | 80M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 100MF9W | 96 | MO |
| 3550-3700 MHz | 5 | 0.05ppm | 80M0F9W | 96 | MO |
| 3550-3700 MHz | 354.6 | 0.05ppm | 90M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 354.3 | 0.05ppm | 100MW7D | 96 | EP, MO |
| 3550-3700 MHz | 100 | 0.05ppm | 20M0F9W | 96 | EP, MO |
| 3550-3700 MHz | 50 | 0.05ppm | 10M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 20M0F9W | 96 | MO |
| 3550-3700 MHz | 5 | 0.05ppm | 10M0F9W | 96 | MO |
| 3550-3700 MHz | 75 | 0.05ppm | 15M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 30M0F9W | 96 | MO |
| 3550-3700 MHz | 5 | 0.05ppm | 15M0F9W | 96 | MO |
| 3550-3700 MHz | 100 | 0.05ppm | 20M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 40M0F9W | 96 | MO |
| 3550-3700 MHz | 150.2 | 0.05ppm | 30M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 50M0F9W | 96 | MO |
| 3550-3700 MHz | 200.3 | 0.05ppm | 40M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 5 | 0.05ppm | 60M0F9W | 96 | MO |
| 3550-3700 MHz | 250.3 | 0.05ppm | 50M0W7D | 96 | EP, MO |
| 3550-3700 MHz | 300.5 | 0.05ppm | 60M0W7D | 96 | EP, MO |
Grants
TCB Grant - Application yawvI3Ei2zAUMBHn1BfmgQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, PO15 5RL United Kingdom |
Date of Grant: 02/06/2020 Application Dated: 01/30/2020 |
| Ericsson AB |
| PDU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Class II Permissive change as described in this filing. Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application yawvI3Ei2zAUMBHn1BfmgQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PDU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 02/06/2020 Application Dated: 01/30/2020 |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Class II Permissive change as described in this filing. Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, PO15 5RL United Kingdom |
Date of Grant: 04/14/2020 Application Dated: 04/13/2020 |
| Ericsson AB |
| PDU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Class II Permissive change as described in this filing. Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application xuCsyU56uDN2kSetp9ZXig==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PDU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 04/14/2020 Application Dated: 04/13/2020 |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Class II Permissive change as described in this filing. Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT Octagon House, Concorde Way, Segensworth North, Fareham, PO15 5RL United Kingdom |
Date of Grant: 09/23/2019 Application Dated: 09/12/2019 |
| Ericsson AB |
| PDU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 210 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application ggYhCl548FqJua4jg8ogFQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PDU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 09/23/2019 Application Dated: 09/12/2019 |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 210 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 09/07/2023 Application Dated: 08/08/2023 |
| Ericsson AB |
| PEU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Peter Moberg , Head of PEU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 210 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker(controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application eXsC8XfO2EUHlKjNLNOIoQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PEU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 09/07/2023 Application Dated: 08/08/2023 |
| Attention: Peter Moberg , Head of PEU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| Limited Single Modular Approval. The power output listed is the manufacturers Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 210 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker(controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 06/06/2023 Application Dated: 05/30/2023 |
| Ericsson AB |
| PEU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Peter Moberg , Head of PEU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 10M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 15M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 30M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 40M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 50M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 60M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 70M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 80M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 90M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 100MF9W |
| Class II Permissive change to add 10MHz and 15 MHz bandwidths to NR. Limited Single Modular Approval. The listed power output 50W and 100W is the manufacturer Max EIRP for LTE, 5W is the manufacturer Max conducted power per port for NR. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application AMQJDfLRCC9dXfPU+qXj5Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PEU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 06/06/2023 Application Dated: 05/30/2023 |
| Attention: Peter Moberg , Head of PEU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 10M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 15M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 30M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 40M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 50M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 60M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 70M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 80M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 90M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 100MF9W |
| Class II Permissive change to add 10MHz and 15 MHz bandwidths to NR. Limited Single Modular Approval. The listed power output 50W and 100W is the manufacturer Max EIRP for LTE, 5W is the manufacturer Max conducted power per port for NR. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 02/18/2022 Application Dated: 02/14/2022 |
| Ericsson AB |
| PDU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 30M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 40M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 50M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 60M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 70M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 80M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 90M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 100MF9W |
| Class II Permissive change as described in this filing. Limited Single Modular Approval. The listed power output 50W and 100W is the manufacturer Max EIRP for LTE, 5W is the manufacturer Max conducted power per port for NR. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application 7OK4v1XDrlH+abC4/EIYHQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PDU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 02/18/2022 Application Dated: 02/14/2022 |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 20M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 30M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 40M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 50M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 60M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 70M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 80M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 90M0F9W |
| MO | 96 | 3550.0 - 3700.0 | 5.0 | 0.05 PM | 100MF9W |
| Class II Permissive change as described in this filing. Limited Single Modular Approval. The listed power output 50W and 100W is the manufacturer Max EIRP for LTE, 5W is the manufacturer Max conducted power per port for NR. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 10/03/2023 Application Dated: 09/11/2023 |
| Ericsson AB |
| PEU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Peter Moberg , Head of PEU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 75.0 | 0.05 PM | 15M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 150.2 | 0.05 PM | 30M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 200.3 | 0.05 PM | 40M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 250.3 | 0.05 PM | 50M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 300.5 | 0.05 PM | 60M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 350.5 | 0.05 PM | 70M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 354.6 | 0.05 PM | 80M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 354.6 | 0.05 PM | 90M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 354.3 | 0.05 PM | 100MW7D |
| Class II Permissive change to support additional external antenna max average Gain 6.7dBi, Limited Single Modular Approval. The power output listed is the manufacturer Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application 0pbDZR/1O4DxTltR8Himxw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PEU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 10/03/2023 Application Dated: 09/11/2023 |
| Attention: Peter Moberg , Head of PEU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRC161746-1 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | Remote Radio Unit which supports LTE and NR |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0F9W |
| EP MO | 96 | 3550.0 - 3700.0 | 50.0 | 0.05 PM | 10M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 75.0 | 0.05 PM | 15M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 100.0 | 0.05 PM | 20M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 150.2 | 0.05 PM | 30M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 200.3 | 0.05 PM | 40M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 250.3 | 0.05 PM | 50M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 300.5 | 0.05 PM | 60M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 350.5 | 0.05 PM | 70M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 354.6 | 0.05 PM | 80M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 354.6 | 0.05 PM | 90M0W7D |
| EP MO | 96 | 3550.0 - 3700.0 | 354.3 | 0.05 PM | 100MW7D |
| Class II Permissive change to support additional external antenna max average Gain 6.7dBi, Limited Single Modular Approval. The power output listed is the manufacturer Max EIRP. This transmitter must only be operated in the grantee's RBS systems. This device is limited to outdoor operations. This transmitter supports single and multi-carrier operation in LTE and NR mode. The internal antenna used for this transmitter must be installed to provide a separation distance of at least 290 cm from the General Public (uncontrolled exposure) or 90 cm from an Occupational Worker (controlled exposure). Grantee is responsible to ensure the individual devices in the final hosts compliance with 96.41(B) EIRP limits for Category B CBSD. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. External antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance for these external antennas is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-locating requirements of 1.1307 (b)(3). |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |