FCC ID TA8AKRY901515-2
Remote Radio Base Station
by Ericsson AB
Grantee Code: TA8 Product Code: AKRY9015152
Latest application date: 2022-05-13
Documents for this grantee are blocked from local display. Public filing metadata and document detail pages remain available, with links to the FCC attachment forwarder and document sources.
FCC ID Device Details
| FCC ID | TA8AKRY901515-2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | TA8 |
| Product Code | AKRY9015152 |
| Applicant Business | Ericsson AB 🇸🇪 |
| Related Domains | |
| Equipment Class | Remote Radio Base Station |
| Test Firm | TUV SUD Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 3700-3980 MHz | Class II permissive change or modification of presently authorized equipment | 2022-05-13 |
| 3700-3980 MHz | Original Equipment | 2022-02-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos Blocked | External Photos | 2022-08-21 | PDF 255.8 KB |
| ID Label Blocked | ID Label/Location Info | 2022-02-22 | PDF 161.4 KB |
| Test Setup Photos Blocked | Test Setup Photos | 2022-08-21 | PDF 606.7 KB |
| EMF test report Blocked | RF Exposure Info | 2022-05-13 | PDF 657.7 KB |
| RF Exposure Report Blocked | Test Report | 2022-02-22 | PDF 501.7 KB |
| RF Test Report Blocked | Test Report | 2022-02-22 | PDF 1.6 MB |
| Test Report Blocked | Test Report | 2022-02-22 | PDF 2.1 MB |
| Attestation Blocked | Attestation Statements | 2022-02-22 | PDF 366.9 KB |
| Permissive change letter Blocked | Cover Letter(s) | 2022-05-13 | PDF 87.5 KB |
| Confidentiality Letter Blocked | Cover Letter(s) | 2022-02-22 | PDF 84.9 KB |
| Letter Blocked | Cover Letter(s) | 2022-02-22 | PDF 88.6 KB |
| User Manual Metadata only | Users Manual | PDF 5 MB | |
| Internal Photos Metadata only | Internal Photos | PDF 711.6 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 55.3 KB | |
| Schematics Metadata only | Schematics | PDF 2.4 MB | |
| Operational Description Metadata only | Operational Description | PDF 433.3 KB | |
| Radio Description Metadata only | Operational Description | PDF 866 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 2.3 MB |
Application Information
| Application ID | i3o876gBOzhJ1/DZEbwsrw== |
|---|---|
| Final Action Date | 2022-05-13 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0024080715 |
| Model | AKRY901515-2 |
| Frequency Range | 3700-3980 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | Remote Radio Base Station |
| Responsible Party | Igor Tasevski, Head of PDU Radio, igor.tasevski@ericsson.com |
| Test Firm | Nathan Emery, TUV SUD Limited, Nathan.Emery@tuvsud.com |
| TCB Email | Tom.Twynam@tuv-sud.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | The power output listed is conducted per port. This transmitter must only be operated in the grantees RBS systems. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| i3o876gBOzhJ1/DZEbwsrw== | 2022-05-13 | Class II permissive change or modification of presently authorized equipment |
| mv7Ubfve8JWz7Jkrxn47zg== | 2022-02-22 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application mv7Ubfve8JWz7Jkrxn47zg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 02/22/2022 Application Dated: 02/22/2022 |
| Ericsson AB |
| PDU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRY901515-2 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Remote Radio Base Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 20M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 40M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 60M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 80M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 100MF9W |
| The power output listed is conducted per port. This transmitter must only be operated in the grantees RBS systems. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application mv7Ubfve8JWz7Jkrxn47zg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PDU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 02/22/2022 Application Dated: 02/22/2022 |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRY901515-2 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Remote Radio Base Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 20M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 40M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 60M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 80M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 100MF9W |
| The power output listed is conducted per port. This transmitter must only be operated in the grantees RBS systems. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV SUD BABT UNLIMITED Octagon House, Concorde Way Segensworth North Fareham, PO15 5RL United Kingdom |
Date of Grant: 05/13/2022 Application Dated: 05/13/2022 |
| Ericsson AB |
| PDU Radio |
| Torshamnsgatan 23 |
| Stockholm, 164 80 Sweden |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRY901515-2 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Remote Radio Base Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 20M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 40M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 60M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 80M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 100MF9W |
| The power output listed is conducted per port. This transmitter must only be operated in the grantees RBS systems. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application i3o876gBOzhJ1/DZEbwsrw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ericsson AB PDU Radio Torshamnsgatan 23 Stockholm, 164 80 Sweden |
Date of Grant: 05/13/2022 Application Dated: 05/13/2022 |
| Attention: Igor Tasevski , Head of PDU Radio |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TA8AKRY901515-2 |
| Name of Grantee: | Ericsson AB |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Remote Radio Base Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 20M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 40M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 60M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 80M0F9W |
| MO | 27 | 3700.0 - 3980.0 | 0.4 | 0.1 PM | 100MF9W |
| The power output listed is conducted per port. This transmitter must only be operated in the grantees RBS systems. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |