RF Exposure Evaluation Declaration
Product Name :
FlexAP
Model No.
(For FCC & IC):
Flex-AP-ED, Flex-AP-ES, Flex-AP-S, Flex-AP-D
(Only for FCC):
Flex-AP-ED-XC, Flex-AP-ES-XC,Flex-AP-S-XC,
Flex-AP-D-XC
FCC ID
TDB-FLEX-AP
Applicant : Sensys Networks Inc.
Address : Suite 110, 1608 Fourth Street, Berkeley, CA, 94710, USA
Date of Receipt : Jan. 13th, 2017
Test Date
: Jan. 13th, 2017~ Apr. 06th, 2017
Issued Date
: Apr. 27th, 2017
Report No.
: 1712066R-RF-US-P20V02
Report Version : V1.0
The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by CNAS, TAF or any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing & Certification (Suzhou)
Co., Ltd.
Report No: 1712066R-RF-US-P20V02
Tes t R e p o r t C e r t i f i c a t i o n
Issued Date : Apr. 27th, 2017
Report No. : 1712066R-RF-US-P20V02
Product Name
Applicant
Address
Manufacturer
Address
Model No.
FCC ID
EUT Voltage
Test Voltage
Applicable Standard
Test Result
Performed Location
Documented By
FlexAP
Sensys Networks Inc.
Suite 110, 1608 Fourth Street, Berkeley, CA, 94710, USA
Sensys Networks Inc.
Suite 110, 1608 Fourth Street, Berkeley, CA, 94710, USA
(For FCC & IC):
Flex-AP-ED, Flex-AP-ES, Flex-AP-S, Flex-AP-D
(Only for FCC):
Flex-AP-ED-XC, Flex-AP-ES-XC,Flex-AP-S-XC,
Flex-AP-D-XC
: TDB-FLEX-AP
: PoE 48V
: PoE 48V
: KDB 447498 D01v06
: Complied
: DEKRA Testing and Certification (Suzhou) Co., Ltd.
No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
215006, Jiangsu, China
TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
FCC Registration Number: 800392
(Adm. Specialist: Kathy Feng)
Reviewed By
(Senior Engineer: Frank He )
Approved By
(Engineering Manager: Harry Zhao )
Page: 2 of 5
Report No: 1712066R-RF-US-P20V02
1.
RF Exposure Evaluation
1.1. Limits
According to KDB 447498 D01 General RF Exposure Guidance v06
4.3.1 Standalone SAR test exclusion considerations
1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)]
≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where
• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison
• 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.
2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
determined according to the following, and as illustrated in Appendix B:
a) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz
b) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·10] mW at > 1500 MHz and ≤ 6 GHz
3) The 1-g and 10-g SAR test exclusion thresholds for below 100 MHz at test separation distances ≤ 50 mm
are determined by:
a) The power threshold at the corresponding test separation distance at 100 MHz in step 2) is
multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm
b) The power threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
separation distances ≤ 50 mm
c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be
applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be
acceptable. Note: when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
determine SAR test exclusion.
Page: 3 of 5
Report No: 1712066R-RF-US-P20V02
1.2. Test Procedure
Software provided by client enabled the EUT to transmit and receive data at lowest, middle
and highest channel individually.
The temperature and related humidity: 18℃and 78% RH.
1.3. Test Result of RF Exposure Evaluation
Product
FlexAP
Test Item
RF Exposure Evaluation
Test Site
AC-6

Antenna Gain:
Antenna manufacturer
N/A
Antenna Delivery
1*TX+1*RX
Antenna technology
SISO
2*TX+2*RX
Basic
MIMO
CDD
Beam-forming
Antenna Type
External
Dipole
PIFA
Internal
PCB
Ceramic Chip Antenna
Microstrip Patch Antenna
Antenna Gain
5.5dBi
Page: 4 of 5
3*TX+3*RX
Report No: 1712066R-RF-US-P20V02
Based on The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm and the formula below:
Pmax Pmax
Band
BT
Exposure
Condition
Body
Stand-alone
Distance
f(GHz)
(dBm)
9.3
(mw)
8.51
calculation
Test
result
exclusion
(mm)
SAR Test
threshold
2.405
2.639
Conclusion: 2402MHz-2480MHz SAR was not required.
The End
Page: 5 of 5
3.00
No
Download: FLEX-AP FlexAP RF Exposure Info RF Exposure Sensys Networks, Inc.
Mirror Download [FCC.gov]FLEX-AP FlexAP RF Exposure Info RF Exposure Sensys Networks, Inc.
Document ID3390523
Application IDD8L6F8YV52D/EZQkqvJ0Fg==
Document DescriptionRF Exposure
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize15.33kB (191576 bits)
Date Submitted2017-05-15 00:00:00
Date Available2017-05-15 00:00:00
Creation Date2017-10-24 22:20:26
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-24 22:20:26
Document TitleRF Exposure
Document CreatorPScript5.dll Version 5.2.2
Document Author: A316772

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:9c48ed68-9b26-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:07 11:47:32Z
Create Date                     : 2017:07:07 11:47:32Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:9c48ed68-9b26-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled