FCC ID TDB-NODE-LP
FlexNode Line Powered Radio
by Sensys Networks, Inc.
Grantee Code: TDB Product Code: NODELP
Latest application date: 2017-08-31
FCC ID Device Details
| FCC ID | TDB-NODE-LP |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | TDB |
| Product Code | NODELP |
| Applicant Business | Sensys Networks, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | FlexNode Line Powered Radio |
| Test Firm | Dongguan Dongdian Testing Service Co.,Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2405-2480 MHz | Original Equipment | 2017-08-31 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual - 1 | Users Manual | 2017-08-31 | PDF 746.7 KB |
| User Manual - 2 | Users Manual | 2017-08-31 | PDF 2.7 MB |
| Internal Photos | Internal Photos | 2017-08-31 | PDF 1 MB |
| External Photos | External Photos | 2017-08-31 | PDF 596.8 KB |
| ID Label and Label Location | ID Label/Location Info | 2017-08-31 | PDF 45.3 KB |
| ID Label and Location info. | ID Label/Location Info | 2017-08-31 | PDF 290.1 KB |
| Test Setup Photos | Test Setup Photos | 2017-08-31 | PDF 379.9 KB |
| Test Report | Test Report | 2017-08-31 | PDF 2.8 MB |
| Agent Letter | Cover Letter(s) | 2017-08-31 | PDF 128.1 KB |
| FCC Confidentiality Letter | Cover Letter(s) | 2017-08-31 | PDF 64 KB |
| Letter from Sensys Network | Cover Letter(s) | 2017-08-31 | PDF 229.3 KB |
| RF Exposure Info. | RF Exposure Info | 2017-08-31 | PDF 148.9 KB |
| Block Diagram Metadata only | Block Diagram | PDF 118.3 KB | |
| Circuit diagram Metadata only | Schematics | PDF 65.9 KB | |
| Operation description Metadata only | Operational Description | PDF 209.7 KB | |
| Operation description - Antenna 1 spec. Metadata only | Operational Description | PDF 615.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 209.8 KB | |
| Operational Description - Antenna 2 Spec. Metadata only | Operational Description | PDF 306.4 KB | |
| Operational Description - Antenna 3 Spec. Metadata only | Operational Description | PDF 734.8 KB |
Application Information
| Application ID | 50y56RIkDsizqRvXkgdPBQ== |
|---|---|
| Final Action Date | 2017-08-31 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0013585526 |
| Model | NODE-LP |
| Frequency Range | 2405-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | FlexNode Line Powered Radio |
| Responsible Party | Robert Kavaler, VP Engineering, kavaler@sensysnetworks.com |
| Test Firm | Jamy Yu, Dongguan Dongdian Testing Service Co.,Ltd, yqaly@163.com |
| TCB Email | LST.FRE.CertNotice@ul.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Listed output power is conducted. This device can only be installed by Sensys Networks Inc. or authorized installer. This device can not be sold to the general public or installed by the end user. Only antenna(s) documented in this filings may be used with this transmitter. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 50y56RIkDsizqRvXkgdPBQ== | 2017-08-31 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2405-2480 MHz | 0.0023000 | 15C |
Grants
TCB Grant - Application 50y56RIkDsizqRvXkgdPBQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 08/31/2017 Application Dated: 08/31/2017 |
| Sensys Networks, Inc. |
| 1608 Fourth Street, Suite 200 |
| Berkeley, CA 94710 |
| Attention: Robert Kavaler , VP Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TDB-NODE-LP |
| Name of Grantee: | Sensys Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | FlexNode Line Powered Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2480.0 | 0.0023 |
| Listed output power is conducted. This device can only be installed by Sensys Networks Inc. or authorized installer. This device can not be sold to the general public or installed by the end user. Only antenna(s) documented in this filings may be used with this transmitter. |
EAS Grant - Application 50y56RIkDsizqRvXkgdPBQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sensys Networks, Inc. 1608 Fourth Street, Suite 200 Berkeley, CA 94710 United States |
Date of Grant: 08/31/2017 Application Dated: 08/31/2017 |
| Attention: Robert Kavaler , VP Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TDB-NODE-LP |
| Name of Grantee: | Sensys Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | FlexNode Line Powered Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2480.0 | 0.0023 |
| Listed output power is conducted. This device can only be installed by Sensys Networks Inc. or authorized installer. This device can not be sold to the general public or installed by the end user. Only antenna(s) documented in this filings may be used with this transmitter. |
| Mail To: |