FCC ID TE7D5V1

AC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router

by TP-Link Technologies Co., Ltd.

Grantee Code: TE7   Product Code: D5V1
Latest application date: 2014-11-05

FCC ID Device Details

FCC IDTE7D5V1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeTE7
Product CodeD5V1
Applicant BusinessTP-Link Technologies Co., Ltd. 🇨🇳
Related Domains tp-link.com
Equipment ClassAC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2014-11-05
5180-5240 MHzOriginal Equipment2014-11-05

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2014-11-05PDF 2.8 MB
Internal PhotosInternal Photos2014-11-05PDF 576.3 KB
External PhotosExternal Photos2014-11-05PDF 332.1 KB
FCC ID LabelID Label/Location Info2014-11-05PDF 874.8 KB
FCC ID Label LocationID Label/Location Info2014-11-05PDF 293.6 KB
Test Setup PhotoTest Setup Photos2014-11-05PDF 162 KB
Test Report for DTSTest Report2014-11-05PDF 4.1 MB
Test Report for NIITest Report2014-11-05PDF 488.4 KB
Confidentiality Request LetterCover Letter(s)2014-11-05PDF 65.4 KB
Declaration Letter for AD HoCCover Letter(s)2014-11-05PDF 30.5 KB
POACover Letter(s)2014-11-05PDF 78.1 KB
MPE ReportRF Exposure Info2014-11-05PDF 49.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 6.8 KB
Schematics Metadata onlySchematicsPDF 490.2 KB
Operational Description-1 Metadata onlyOperational DescriptionPDF 24.5 KB
Operational Description-2 Metadata onlyOperational DescriptionPDF 84.2 KB

Application Information

Application IDzjXrq39TF5pwrZESRf5SnA==
Final Action Date2014-11-05
Application PurposeOriginal Equipment
Applicant FRN0013661145
ModelD5V1
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionAC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router
Responsible PartyJing Huang, Regulatory Compliance Manager, certification@tp-link.com , 75521534921
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum combined peak conducted output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 3T3R Spatial Multiplexing MIMO configuration as described in this filing. This device is restricted to indoor usage only. This device has 20, 40 MHz, and 80MHz BW modes.

Applications

Application IDDatePurpose
zjXrq39TF5pwrZESRf5SnA==2014-11-05Original Equipment
eO10zVXtjIzBHskd9gwGKQ==2014-11-05Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.77815C68, CC, MO
2422-2452 MHz0.628115C68, CC, MO
5180-5240 MHz0.052815E39, 68, CC, MO
5190-5230 MHz0.05715E39, 68, CC, MO
5210 MHz0.046915E39, 68, CC, MO
5745-5825 MHz0.641215C68, CC, MO
5755-5795 MHz0.587515C68, CC, MO
5775 MHz0.589415C68, CC, MO

Grants

TCB Grant - Application zjXrq39TF5pwrZESRf5SnA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 11/05/2014

Application Dated: 11/05/2014
TP-Link Technologies Co., Ltd.
Building 24 (floors 1,3,4,5) and 28 (floors1-4),
Central Science and Technology Park,Nanshan
Shenzhen, 518057
China
 
Attention: Jing Huang , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  TE7D5V1
Name of Grantee:  TP-Link Technologies Co., Ltd.
Equipment Class: Digital Transmission System
Notes: AC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
68 CC MO 15C 2412.0  -  2462.0 0.778  
68 CC MO 15C 2422.0  -  2452.0 0.6281  
68 CC MO 15C 5745.0  -  5825.0 0.6412  
68 CC MO 15C 5755.0  -  5795.0 0.5875  
68 CC MO 15C 5775.0  -  5775.0 0.5894  

Output Power listed is the maximum combined peak conducted output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 3T3R Spatial Multiplexing MIMO configuration as described in this filing. This device is restricted to indoor usage only. This device has 20, 40 MHz, and 80MHz BW modes.

68: This grant does not pertain to equipment approval requirements under Part 68.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application zjXrq39TF5pwrZESRf5SnA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TP-Link Technologies Co., Ltd.
Building 24 (floors 1,3,4,5) and 28 (floors1-4), Central Science and Technology Park,Nanshan
Shenzhen, 518057
China
  Date of Grant: 11/05/2014

Application Dated: 11/05/2014
 
Attention: Jing Huang , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  TE7D5V1
Name of Grantee:  TP-Link Technologies Co., Ltd.
Equipment Class: Digital Transmission System
Notes: AC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
68 CC MO 15C 2412.0  -  2462.0 0.778  
68 CC MO 15C 2422.0  -  2452.0 0.6281  
68 CC MO 15C 5745.0  -  5825.0 0.6412  
68 CC MO 15C 5755.0  -  5795.0 0.5875  
68 CC MO 15C 5775.0  -  5775.0 0.5894  

Output Power listed is the maximum combined peak conducted output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 3T3R Spatial Multiplexing MIMO configuration as described in this filing. This device is restricted to indoor usage only. This device has 20, 40 MHz, and 80MHz BW modes.


68: This grant does not pertain to equipment approval requirements under Part 68.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application eO10zVXtjIzBHskd9gwGKQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 11/05/2014

Application Dated: 11/05/2014
TP-Link Technologies Co., Ltd.
Building 24 (floors 1,3,4,5) and 28 (floors1-4),
Central Science and Technology Park,Nanshan
Shenzhen, 518057
China
 
Attention: Jing Huang , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  TE7D5V1
Name of Grantee:  TP-Link Technologies Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
39 68 CC MO 15E 5180.0  -  5240.0 0.0528  
39 68 CC MO 15E 5190.0  -  5230.0 0.057  
39 68 CC MO 15E 5210.0  -  5210.0 0.0469  

Output Power listed is the maximum combined conducted output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 3T3R Spatial Multiplexing MIMO configuration as described in this filing. This device is restricted to indoor usage only. This device has 20, 40 MHz, and 80MHz BW modes.

39: This sub-band complies with the new rules for U-NII devices adopted under Docket No. 13-49. This device may not be sold or marketed after June 1, 2016, unless all grant-listed U-NII sub-bands demonstrate compliance with Docket No. 13-49.
68: This grant does not pertain to equipment approval requirements under Part 68.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application eO10zVXtjIzBHskd9gwGKQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

TP-Link Technologies Co., Ltd.
Building 24 (floors 1,3,4,5) and 28 (floors1-4), Central Science and Technology Park,Nanshan
Shenzhen, 518057
China
  Date of Grant: 11/05/2014

Application Dated: 11/05/2014
 
Attention: Jing Huang , Regulatory Compliance Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  TE7D5V1
Name of Grantee:  TP-Link Technologies Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC1200 Wireless Dual Band Gigabit ADSL2+ Modem Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
39 68 CC MO 15E 5180.0  -  5240.0 0.0528  
39 68 CC MO 15E 5190.0  -  5230.0 0.057  
39 68 CC MO 15E 5210.0  -  5210.0 0.0469  

Output Power listed is the maximum combined conducted output power as indicated in the filing. This device must be installed and operated to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. Device is operating in a 3T3R Spatial Multiplexing MIMO configuration as described in this filing. This device is restricted to indoor usage only. This device has 20, 40 MHz, and 80MHz BW modes.


39: This sub-band complies with the new rules for U-NII devices adopted under Docket No. 13-49. This device may not be sold or marketed after June 1, 2016, unless all grant-listed U-NII sub-bands demonstrate compliance with Docket No. 13-49.
68: This grant does not pertain to equipment approval requirements under Part 68.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: