FCC ID TKHSP102
TSM1/M110 Dual Band GSM 850/1900 Handset
by Vitelcom Mobile Technology, S.A.
Grantee Code: TKH Product Code: SP102
Latest application date: 2006-03-17
FCC ID Device Details
| FCC ID | TKHSP102 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | TKH |
| Product Code | SP102 |
| Applicant Business | Vitelcom Mobile Technology, S.A. 🇪🇸 |
| Related Domains | |
| Equipment Class | TSM1/M110 Dual Band GSM 850/1900 Handset |
| Test Firm | DEKRA Testing and Certification, S.A.U. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2006-03-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2006-03-17 | PDF 1.3 MB |
| Internal Photographs | Internal Photos | 2006-03-17 | PDF 123.8 KB |
| External Photographs | External Photos | 2006-03-17 | PDF 129.1 KB |
| Label Location | ID Label/Location Info | 2006-03-17 | PDF 123.7 KB |
| Label Sample | ID Label/Location Info | 2006-03-17 | PDF 22.2 KB |
| RF Test Setup Photographs | Test Setup Photos | 2006-03-17 | PDF 1.9 MB |
| SAR 850 Test Setup Photographs | Test Setup Photos | 2006-03-17 | PDF 394.5 KB |
| SAR Test Setup Phographs 1900 | Test Setup Photos | 2006-03-17 | PDF 881.5 KB |
| RF Test Report | Test Report | 2006-03-17 | PDF 3.5 MB |
| SAR Test Report 850 | RF Exposure Info | 2006-03-17 | PDF 2.6 MB |
| SAR test report 1900 | RF Exposure Info | 2006-03-17 | PDF 2.5 MB |
| 1519 Compliance Statement | Cover Letter(s) | 2006-03-17 | PDF 34.4 KB |
| Authorization Letter Vitelcom to MET | Cover Letter(s) | 2006-03-17 | PDF 21.2 KB |
| Authorization Letter from Vitelcom to CETECOM | Cover Letter(s) | 2006-03-17 | PDF 2.2 MB |
| Confidentiality Request | Cover Letter(s) | 2006-03-17 | PDF 18.3 KB |
Application Information
| Application ID | vgEa8neHm5H7NISa8qPfoQ== |
|---|---|
| Final Action Date | 2006-03-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0013892781 |
| Model | SP102 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | TSM1/M110 Dual Band GSM 850/1900 Handset |
| Responsible Party | Rafael Abad, Validation Manager, rabad@vitelcom.es |
| Test Firm | Rafael Lopez Martin, DEKRA Testing and Certification, S.A.U., rafael.lopez@dekra.com |
| TCB Email | tcbinfo@metlabs.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power is ERP for Pt. 22 and EIRP for Pt. 24. SAR compliance for body- worn operating configuration is based on a testing with 1.5 cm spacing from back of the phone and the body. Body-worn holsters or similar accessories must not contain any metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user’s body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Maximum reported SAR values for this FCC ID are: Pt. 24: 0.205 W/kg Head, 1.152 W/kg body; Pt. 22: 0.478 W/kg head, 0.413 W/kg body. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| vgEa8neHm5H7NISa8qPfoQ== | 2006-03-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application vgEa8neHm5H7NISa8qPfoQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Electrical and Electronic Testing NA, Inc 914 W. Patapsco Avenue Baltimore, MD 21230-3432 |
Date of Grant: 03/17/2006 Application Dated: 03/17/2006 |
| Vitelcom Mobile Technology, S.A. |
| Avda. Juan López Peñalver, 7 |
| 29590 - P.T.A. Campanillas, Málaga, Spain |
| Málaga, Spain |
| Attention: Rafael Abad , Validation Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TKHSP102 |
| Name of Grantee: | Vitelcom Mobile Technology, S.A. |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | TSM1/M110 Dual Band GSM 850/1900 Handset |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 1.95 | 1.0 PM | 247KGXW |
| BC | 24E | 1850.2 - 1909.8 | 0.99 | 1.0 PM | 243KGXW |
| Output Power is ERP for Pt. 22 and EIRP for Pt. 24. SAR compliance for body- worn operating configuration is based on a testing with 1.5 cm spacing from back of the phone and the body. Body-worn holsters or similar accessories must not contain any metallic component in the assembly and must provide at least 1.5 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Maximum reported SAR values for this FCC ID are: Pt. 24: 0.205 W/kg Head, 1.152 W/kg body; Pt. 22: 0.478 W/kg head, 0.413 W/kg body. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application vgEa8neHm5H7NISa8qPfoQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Vitelcom Mobile Technology, S.A. Avda. Juan López Peñalver, 7 29590 - P.T.A. Campanillas, Málaga, Spain Málaga, Spain |
Date of Grant: 03/17/2006 Application Dated: 03/17/2006 |
| Attention: Rafael Abad , Validation Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TKHSP102 |
| Name of Grantee: | Vitelcom Mobile Technology, S.A. |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | TSM1/M110 Dual Band GSM 850/1900 Handset |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 1.95 | 1.0 PM | 247KGXW |
| BC | 24E | 1850.2 - 1909.8 | 0.99 | 1.0 PM | 243KGXW |
| Output Power is ERP for Pt. 22 and EIRP for Pt. 24. SAR compliance for body- worn operating configuration is based on a testing with 1.5 cm spacing from back of the phone and the body. Body-worn holsters or similar accessories must not contain any metallic component in the assembly and must provide at least 1.5 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Maximum reported SAR values for this FCC ID are: Pt. 24: 0.205 W/kg Head, 1.152 W/kg body; Pt. 22: 0.478 W/kg head, 0.413 W/kg body. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |