FS2-D Face Station2 Test Report DCD Suprema Inc.

Suprema Inc. Face Station2

FCC ID Filing: TKWFS2-D
Purchase on Amazon: Face Station2

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 2 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 3 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 4 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 5 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 6 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 7 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 8 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 9 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 10 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 11 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 12 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 13 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 14 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 15 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 16 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 17 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 18 of FS2-D Face Station2 Test Report DCD Suprema Inc.
Page 19 of FS2-D Face Station2 Test Report DCD Suprema Inc.

Test Report for FCC
FCC ID :
Report Number
ESTRFC1703-002
Company name
Applicant
Suprema Inc
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi,
Address
+82-31-710-4908
Telephone
Product name
Product
TKWFS2-D
Face Station2
Model No.
FS2-D
Manufacturer
Suprema Inc
Serial No.
NONE
Country of origin
KOREA
Date of issue
17-Mar-17
17-Feb-17
Test date
Testing
location
347-69, Jungbu-daero 147beon-gil, Majang-myeon, Icheon-si,
Gyeonggi-do 467-811, R. O. Korea
Standard
FCC PART 15 Subpart C(15.209), ANSI C 63.10(2009)
■ Conducted Emission
□ Class A
■ Class B
Test result
OK
■ Radiated Emission
□ Class A
■ Class B
Test result
OK
Test item
Measurement facility registration number
659627
Tested by
Senior Engineer H.K. Lee
(Signature)
Reviewed by
Engineering Manager I.K. Hong
(Signature)
Abbreviation
OK, Pass = Complied,
Fail = Failed, N/A = not applicable
* Note
- This test report is not permitted to copy partly without our permission
- This test result is dependent on only equipment to be used
- This test result based on a single evaluation of one sample of the above mentioned
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 1 of 16
Contents
1. Laboratory Information
2. Description of EUT
3. Test Standards
…………………………………………………………………………
………………………………………………………………………………
…………………………………………………………………………………… 5
4. Measurement condition
………………………………………………………………………… 6
5. Measurement of radiated emission
…………………………………………………………… 8
5.1 Radiated emission limits, general requirements
………………………………………… 8
5.2 Measurement equipment
…………………………………………………………………… 8
5.3 Environmental conditions
…………………………………………………………………… 8
5.4 Test data
……………………………………………………………………………………… 9
6. Measurement of conducted emission
………………………………………………………… 10
…………………………………………………………………… 10
6.1 Measurement equipment
6.2 Environmental conditions …………………………………………………………………… 10
6.3 Test data
……………………………………………………………………………………… 11
7. Photographs of test setup
8. Photographs of EUT
……………………………………………………………………… 12
……………………………………………………………………………… 14
Appendix 1. Special diagram
Appendix 2. Antenna Requirement
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 2 of 16
1. Laboratory Information
1.1 General
This EUT (Equipment Under Test) has been shown to be capable of compliance with the applicable
technical standards and is tested in accordance with the measurement procedures as indicated in
this report.ESTECH Lab attests to accuracy of test data. All measurement reported herein were
performed by ESTECH Co., Ltd.
ESTECH Lab assume full responsibility for the completeness of these measurements and vouch for
the qualifications of all persons taking them.
1.2 Test Lab.
Corporation Name : ESTECH Co., Ltd.
Head Office : Suite 1015 World Meridian II, 123 Gasan Digital 2-ro, Geumcheon-gu,
Seoul 153-759, R. O. Korea
EMC/Telecom/Safety Test Lab : 347-69, Jungbu-daero 147beon-gil, Majang-myeon, Icheon-si,
Gyeonggi-do 467-811, R. O. Korea
1.3 Official Qualification(s)
KCC : Granted Accreditation from Ministry of Information & Communication for EMC, Safety
and Telecommunication
KOLAS : Accredited Lab By Korea Laboratory Accreditation Schema base on CENELEC
FCC : Filed Laboratory at Federal Communications Commission
VCCI : Granted Accreditation from Voluntary Control Council for Interference from ITE
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 3 of 16
2. Description of EUT
2.1 Summary of Equipment Under Test
Product
Model Number
Serial Number
Manufacturer
Country of origin
Operating Frequency
Antenna Type
Modulation Type
Channel Spacing
Face Station2
FS2-D
NONE
Suprema Inc.
KOREA
117.54 kHz
Coil Antenna
ASK
Power Rating
INPUT : (100 - 240) Va.c., (50 - 60) Hz, 1.0 A
OUTPUT : 12 Vd.c., 2.5 A
Receipt Date
: 5-Dec-16
X-tal list(s) or
: The highest operating frequency is CPU 1.4 GHz
Frequencies generated
2.2 General descriptions of EUT
CPU 1.4 GHz Quad Core
Memory 8GB Flash + 1GB RAM
LCD 4” color TFT LCD (Resolution: 480 x 800)
Sound 24 bit/Voice DSP (echo cancel)
Operating temperature -20 °C ~ 50 °C
Storage temperature -40 °C ~ 70 °C
Operating humidity 0 % ~ 80 %, non-condensing
Storage humidity 0 % ~ 90 %, non-condensing
Camera CMOS VGA (720 x 480) pixels
Camera angle Visual : Diagonal 92.7° , IR : Diagonal 58°
Dimension (W x H x D) 141 mm x 125 mm x 164 mm (h)
Weight Device: 610 g (With Wall-Bracket)
RF Option RFID : 13.56 MHz / 117 kHz
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 4 of 16
3. Test Standards
Test Standard : FCC PART 15 (2010)
This Standard sets out the regulations under which an intentional, unintentional, or incidental
radiator may be operated without an individual license. It also contains the technical
specifications, administrative requirements and other conditions relating to the marketing of Part
15 devices.
Test Method : ANSI C 63.4 (2003)
This standard sets forth uniform methods of measurement of radio-frequency (RF) signals and
noise emitted from both unintentional and intentional emitters of RF energy in the frequency range
9 kHz to 40 GHz. Methods for the measurement of radiated and AC power-line conducted radio
noise are covered and may be applied to any such equipment unless otherwise specified by
individual equipment requirements. These methods cover measurement of certain decides that
deliberately radiate energy, such as intentional emitters, but does not cover licensed transmitters.
This standard is not intended for certification/approval of avionic equipment or for industrial,
scientific, and medical (ISM) equipment These method apply to the measurement of individual
units or systems comprised of multiple units
Summary of Test Results
Applied Satandard : 47 CFR Part 15, Subpart C
Standard
Test Type
Result
Remark
15.203
Antenna Requirement
Pass
See Appendix 2
15.207
AC Power Conducted Emission
Pass
Meet the requirement
15.205
Restricted bands
Pass
Meet the requirement
15.209
Radiated Emission
Pass
Meet the requirement
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Limit
Page 5 of 16
4. Measurement Condition
4.1 EUT Operation.
-The EUT was tested, under transmission / receiving
1. Normal communication with RF OUT Frequeny(117 kHz).
2. Monitoring the operation status of frequency by using RF CARD.
4.2 Configuration and Peripherals
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 6 of 16
4.3 EUT and Support equipment
Equipment Name
Model Name
S/N
Manufacturer
Remark
(FCC ID)
Face Station2
FS2-D
NONE
Suprema Inc
EUT
Adapter
JPW128KA1200N05
NONE
BridgePower Corp.
RF CARD
NONE
NONE
Suprema Inc
4.4 Cable Connecting
Start Equipment
End Equipment
Cable Standard
Remark
Name
I/O port
Name
I/O port
Length
Shielded
Face Station2
Power
Adapter
Unshielded
Face Station2
Wireless
(117 kHz)
RF CARD
Wireless
(117 kHz)
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 7 of 16
5. Measurement of radiated disturbance
The EUT was placed on the top of a rotating table 0.8 m above the ground at a 3 m Open test site. The table was rotated
360 ° to determine the position of the highest radiation.Then antenna is a loop antenna is fixed at one meter above the
ground to determine the maximum value of the field strength. Both parallel and perpendicular of the antenna are set to
make the measurement. For each suspected emission, the EUT was arranged to its worst case and then the table was
turned from 0 degrees to 360 ° to find the maximum reading. The test-receiver system was set to Peak Detect Function
and Specified Bandwidth with Maximum Hold Mode.
5.1 Radiated emission limits, general requirements
Except as provided elsewhere in this Subpart, the emissions from an intentional radiator
shall not exceed the field strength levels specified in the following table:
Frequency
(MHz)
0.009-0.490
0.490-1.705
1.705-30
30-88
88-216
216-960
Above 960
* dBuV/m=20*log(uV/m)
Field Strength(microvolt/meter)
Distance(meter)
2400/F(KHz)
24000/F(KHz)
30
100**
150**
200**
500
300
30
30
* Distance factor=40dB / decade(15.31(f))
5.2 Measurement equipments
Equipment Name
Type
Manufacturer
Serial No.
Next
Calibration date
TEST Receiver
ESCI7
ROHDE & SCHWARZ
100916
5-Nov-17
Logbicon Antenna
VULB 9168
SCHWARZBECK
193
12-Oct-18
Turn Table
DT3000-2t
Innco System GmbH
N/A
Antenna Mast
MA4000-EP
Innco System GmbH
N/A
Antenna Master &
Turn table controller
CO2000-P
Innco System GmbH
CO2000/641
/28051111/L
Loop Antenna
HFH2-Z2
ROHDE & SCHWARZ
100188
22-Aug-17
5.3 Environmental Condition
Test Place
10 m Semi-anechoic chamber
Temperature (°C)
: 21.1 ℃
Humidity (%)
: 49.5 % R.H.
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 8 of 16
5.4 Test data (9 kHz ~ 30 MHz)
Test Date : 17-Feb-17
Measurement Distance :
Frequency
(kHz)
Reading
(dB㎶)
Vertical
Position
[Angle]
Height
(m)
117.54
50.98
90 °
0.8
Remark
Correction
Ant
Factor
(dB)
19.58
Factor
Cable
(dB)
0.5
3m
Result Value(Qeas-Peak)
Limit
Result
(dB㎶/m) (dB㎶/m)
105.7
71.06
Margin
(dB)
-34.61
H : Horizontal, V : Vertical
There did not measure any radiated spurious emission in the range 9 kHz to 30 MHz
*There is no found Restricted bands.
*The 300 m limit was converted to 3m Limit using square factor(x) as it was found by
measurements as follows;
3 m Limit(dBuV/m) = 20log(2400/F(KHz))+40log(300/3)= 20log(2400/125)+40log(300/3)
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 9 of 16
5.4 Test data(30 MHz ~ 1 000 MHz)
Test Date :
Measurement Distance :
17-Feb-17
Position Height
(V/H)
(m)
Frequency
(MHz)
Reading
(dB㎶)
243.20
22.35
256.00
21.64
332.80
Correction Factor
3m
Result Value(Quasi-peak)
Ant Factor
(dB)
Cable
(dB)
Limit
(dB㎶/m)
Result
(dB㎶/m)
Margin
(dB)
2.0
11.60
2.41
46.00
36.36
9.64
1.8
12.11
2.48
46.00
36.23
9.77
19.84
1.7
14.40
2.85
46.00
37.09
8.91
405.00
20.06
1.6
15.81
3.18
46.00
39.05
6.95
559.60
14.43
1.0
19.16
3.76
46.00
37.35
8.65
830.10
12.51
1.0
22.91
4.73
46.00
40.15
5.85
Remark
H : Horizontal, V : Vertical
*Result Value = Reading + Antenna + Cable loss
*Correction Factor = Ant Factor + Cable
*The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
Quasi-peak detection
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 10 of 16
6. Measurement of conducted disturbance
The continuous disturbance voltage of AC Mains in the frequency from 0.15 MHz to 30 MHz was
measured in accordance to FCC Part 15 (2010) & ANSI C 63.4 (2003) The test setup was made
according to FCC Part 15 (2010) & ANSI C 63.4 (2003) in a shielded Room. The EUT was placed
on a non-conductive table at least 0.8 m above the ground plan. A grounded vertical reference
plane was positioned in a distance of 0.4 m from the EUT. The distance from the EUT to other
metal surfaces was at least 0.8 m. The EUT was only earthen by its power cord through the line
impedance stabilizing network. The power cord has been bundled to a length of 1.0 m. The test
receiver with Quasi Peak detector complies with CISPR 16.
6.1 Measurement equipments
Equipment Name
Type
Manufacturer
Serial No.
Next Calibration
date
TEST Receiver
ESHS 30
Rohde & Schwarz
828765/002
4-Nov-17
LISN
ESH3-Z5
Rohde & Schwarz
838979/010
4-Nov-17
Pulse Limiter
ESH3Z2
Rohde & Schwarz
NONE
4-Nov-17
6.2 Environmental Condition
Test Place
: Shielded Room
Temperature (°C)
: 21.4 ℃
Humidity (% R.H.) : 50.8 % R.H.
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 11 of 16
6.3 Test data
Test Date :
17-Feb-17
Correction Factor
Frequency
(MHz)
Lisn
(dB)
Cable
(dB)
0.20
0.16
0.20
0.26
0.09
0.60
Quasi-peak Value
Line
(H/N)
Average Value
Limit
(dB㎶)
Reading
(dB㎶)
Result
(dB㎶)
Limit
(dB㎶)
Reading
(dB㎶)
Result
(dB)
63.61
37.02
37.38
53.61
30.62
30.98
0.20
61.43
33.98
34.27
51.43
28.27
28.56
0.10
0.22
56.00
36.22
36.53
46.00
33.70
34.01
0.66
0.10
0.22
56.00
35.87
36.19
46.00
33.01
33.33
0.86
0.17
0.24
56.00
32.15
32.56
46.00
27.17
27.58
20.71
0.59
0.23
60.00
28.38
29.20
50.00
21.46
22.28
Remark
H : Hot Line, N : Neutral Line
*Correction Factor = Lisn + Cable
*Result = Correction Factor + Reading
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 12 of 16
7. Photographs of test setup
7.1 Setup for Radiated Test
[ Test setup for below 30 MHz ]
[ Test setup for above 30 MHz ]
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 13 of 16
7.3 Setup for Conducted Test : 0.15 MHz ~ 30 MHz
[ Front ]
[ Rear ]
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 14 of 16
8.0 Photographs of EUT
[ Front ]
[ Rear ]
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 15 of 16
8.1 Photographs of EUT
[ Front ]
[ Label ]
Report Number : ESTRFC1703-002
EST-P25-IO2-F04 (2016.01.01)
Page 16 of 16
Appendix 1. Special diagram
*HOT LINE
*NEUTRAL LINE
Appendix 2. Antenna Requirement
Requlation
According to §15.203, an intentional radiator shall be designed to ensure that no
antenna other than that furnished by the responsible party shall be used with the
device. The use of a permanently attached antenna or of an antenna that uses a
unique coupling to the intentional radiator shall be considered sufficient to comply
with the provisions of this Section. The manufacturer may design the unit so that
a broken antenna can be replaced by the user, but the use of a standard antenna
jack or electrical connector is prohibited.
Result
-Complied
The transmitter has an integral Loop coil antenna.
Download: FS2-D Face Station2 Test Report DCD Suprema Inc.
Mirror Download [FCC.gov]FS2-D Face Station2 Test Report DCD Suprema Inc.
Document ID3344497
Application IDXq+BS6b13+pI8CvPQJykZA==
Document DescriptionDCD Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize62.74kB (784273 bits)
Date Submitted2017-04-04 00:00:00
Date Available2017-04-04 00:00:00
Creation Date2017-03-20 14:20:32
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-04-03 13:47:24
Document TitleDCD Test Report
Document CreatorPScript5.dll Version 5.2.2
Document Author: User

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : User
Create Date                     : 2017:03:20 14:20:32+09:00
Modify Date                     : 2017:04:03 13:47:24+09:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:04:03 13:47:24+09:00
Format                          : application/pdf
Title                           : ESTRFC1703-002- Suprema Inc-FS2-D_117 kHz_Report.xls
Creator                         : User
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:e2beb252-8cc2-41ea-9b16-b4a44d16c3a7
Instance ID                     : uuid:14b96d22-3a3e-480b-a135-9957fa533584
Page Count                      : 19

Facebook Twitter Google+ RSS © FCCID.io 2017