FCC ID TN7XUR
Fitness equipment console
by Johnson Health Tech. Co., Ltd.
Grantee Code: TN7 Product Code: XUR
Latest application date: 2022-06-30
FCC ID Device Details
| FCC ID | TN7XUR |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | TN7 |
| Product Code | XUR |
| Applicant Business | Johnson Health Tech. Co., Ltd. 🇹🇼 |
| Related Domains | |
| Equipment Class | Fitness equipment console |
| Test Firm | Intertek Testing Services Shanghai |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2022-06-30 |
| 2402-2480 MHz | Original Equipment | 2022-06-30 |
| 2402-2480 MHz | Original Equipment | 2022-06-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-06-30 | PDF 2 MB |
| Internal Photo-ed1 | Internal Photos | 2022-06-30 | PDF 823 KB |
| External Photo | External Photos | 2022-06-30 | PDF 213.2 KB |
| Label Location | ID Label/Location Info | 2022-06-30 | PDF 239.1 KB |
| Test Setup | Test Setup Photos | 2022-06-30 | PDF 230.3 KB |
| Appendix A1_Part1 | Test Report | 2022-06-30 | PDF 5.1 MB |
| Appendix A1_Part2 | Test Report | 2022-06-30 | PDF 1.9 MB |
| Appendix A2 | Test Report | 2022-06-30 | PDF 712 KB |
| Report_15.247-BLE-ed1 | Test Report | 2022-06-30 | PDF 3.2 MB |
| Report_15.247-BT-ed1_Part1 | Test Report | 2022-06-30 | PDF 4.6 MB |
| Report_15.247-BT-ed1_Part2 | Test Report | 2022-06-30 | PDF 4.8 MB |
| Report_15.247-WIFI-ed1_Part1 | Test Report | 2022-06-30 | PDF 5.3 MB |
| Report_15.247-WIFI-ed1_Part2 | Test Report | 2022-06-30 | PDF 5.1 MB |
| Report_15.247-WIFI-ed1_Part3 | Test Report | 2022-06-30 | PDF 5.4 MB |
| Report_15.247-WIFI-ed1_Part4 | Test Report | 2022-06-30 | PDF 5.2 MB |
| Report_15.247-WIFI-ed1_Part5 | Test Report | 2022-06-30 | PDF 861.3 KB |
| Report_15.407-5G WiFi | Test Report | 2022-06-30 | PDF 1 MB |
| ACB-FORM-FCC-Application-Letters-Agency-Letter | Cover Letter(s) | 2022-06-30 | PDF 84.9 KB |
| ACB-FORM-FCC-Application-Letters-Confidentiality-Letter | Cover Letter(s) | 2022-06-30 | PDF 97.4 KB |
| Declaration letter for channel 12 and 13 | Cover Letter(s) | 2022-06-30 | PDF 20.4 KB |
| SDR or Non-SDR device Cover Letter | Cover Letter(s) | 2022-06-30 | PDF 90.7 KB |
| Report_FCC_MPE | RF Exposure Info | 2022-06-30 | PDF 353.5 KB |
| Block diagram-ed1 Metadata only | Block Diagram | PDF 148.7 KB | |
| Schematic of Product Metadata only | Schematics | PDF 569.9 KB | |
| Schematic of RF Module Metadata only | Schematics | PDF 123.3 KB | |
| Confidential_Operation Description Metadata only | Operational Description | PDF 172.7 KB | |
| Security for sofware Metadata only | SDR Software/Security Inf | PDF 142.9 KB |
Application Information
| Application ID | wdEj/tNt3nuuKXXY6ibO6Q== |
|---|---|
| Final Action Date | 2022-06-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0014045942 |
| Model | XUR |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Fitness equipment console |
| Responsible Party | Chih-Feng Wei, Engineer, fungwei@johnsonfitness.com |
| Technical Contact | Eric Li, Intertek Testing Services Limited Shanghai, eric.yw.li@intertek.com |
| Test Firm | Leah Xu, Intertek Testing Services Shanghai, leah.xu@intertek.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. Device is a 802.11 a/n/ac device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz,40 MHz and 80 MHz bandwidth modes and it contains 2.4GHz WiFi, Bluetooth and BLE transmitters. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| wdEj/tNt3nuuKXXY6ibO6Q== | 2022-06-30 | Original Equipment |
| TsY1pv0ZRsOeOiCKFIR2/Q== | 2022-06-30 | Original Equipment |
| 28uy6snWyhLIVUszYAGejg== | 2022-06-30 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application wdEj/tNt3nuuKXXY6ibO6Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 06/30/2022 Application Dated: 06/29/2022 |
| Johnson Health Tech. Co., Ltd. |
| NO. 999, Sec.2, Dongda Rd., Daya Dist., |
| P.O. Box 428, |
| Taichung City, 428 Taiwan |
| Attention: Chih-Feng Wei , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TN7XUR |
| Name of Grantee: | Johnson Health Tech. Co., Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Fitness equipment console |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.054 |
| Output power listed is conducted. Device is a 802.11 a/n/ac device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz,40 MHz and 80 MHz bandwidth modes and it contains 2.4GHz WiFi, Bluetooth and BLE transmitters. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application wdEj/tNt3nuuKXXY6ibO6Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Johnson Health Tech. Co., Ltd. NO. 999, Sec.2, Dongda Rd., Daya Dist., P.O. Box 428, Taichung City, 428 Taiwan |
Date of Grant: 06/30/2022 Application Dated: 06/29/2022 |
| Attention: Chih-Feng Wei , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TN7XUR |
| Name of Grantee: | Johnson Health Tech. Co., Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Fitness equipment console |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.054 |
| Output power listed is conducted. Device is a 802.11 a/n/ac device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz,40 MHz and 80 MHz bandwidth modes and it contains 2.4GHz WiFi, Bluetooth and BLE transmitters. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 06/30/2022 Application Dated: 06/29/2022 |
| Johnson Health Tech. Co., Ltd. |
| NO. 999, Sec.2, Dongda Rd., Daya Dist., |
| P.O. Box 428, |
| Taichung City, 428 Taiwan |
| Attention: Chih-Feng Wei , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TN7XUR |
| Name of Grantee: | Johnson Health Tech. Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Fitness equipment console |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.035 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.00006 |
| Output power listed is conducted. Device is a 802.11 b/g/n device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 5GHz WiFi and Bluetooth transmitters. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application TsY1pv0ZRsOeOiCKFIR2/Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Johnson Health Tech. Co., Ltd. NO. 999, Sec.2, Dongda Rd., Daya Dist., P.O. Box 428, Taichung City, 428 Taiwan |
Date of Grant: 06/30/2022 Application Dated: 06/29/2022 |
| Attention: Chih-Feng Wei , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TN7XUR |
| Name of Grantee: | Johnson Health Tech. Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Fitness equipment console |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.035 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.00006 |
| Output power listed is conducted. Device is a 802.11 b/g/n device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40 MHz bandwidth modes and it contains 5GHz WiFi and Bluetooth transmitters. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 06/30/2022 Application Dated: 06/29/2022 |
| Johnson Health Tech. Co., Ltd. |
| NO. 999, Sec.2, Dongda Rd., Daya Dist., |
| P.O. Box 428, |
| Taichung City, 428 Taiwan |
| Attention: Chih-Feng Wei , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TN7XUR |
| Name of Grantee: | Johnson Health Tech. Co., Ltd. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Fitness equipment console |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0001 |
| Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 2.4GHz WiFi, 5GHz WiFi and BLE transmitters. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 28uy6snWyhLIVUszYAGejg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Johnson Health Tech. Co., Ltd. NO. 999, Sec.2, Dongda Rd., Daya Dist., P.O. Box 428, Taichung City, 428 Taiwan |
Date of Grant: 06/30/2022 Application Dated: 06/29/2022 |
| Attention: Chih-Feng Wei , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | TN7XUR |
| Name of Grantee: | Johnson Health Tech. Co., Ltd. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Fitness equipment console |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0001 |
| Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains 2.4GHz WiFi, 5GHz WiFi and BLE transmitters. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |