FCC ID TPP05M-1

TRI-BAND GSM 900/1800/1900 MHZ MOBILE PHONE

by i-MOBIL S.A. DE C.V.

Grantee Code: TPP   Product Code: 05M1
Latest application date: 2005-12-12

FCC ID Device Details

FCC IDTPP05M-1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeTPP
Product Code05M1
Applicant Businessi-MOBIL S.A. DE C.V. 🇲🇽
Related Domains i-mobil.com
Equipment ClassTRI-BAND GSM 900/1800/1900 MHZ MOBILE PHONE
Test FirmShenZhen Electronic Product Quality Testing Center

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2005-12-12

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2005-12-12PDF 670.9 KB
Internal PhotosInternal Photos2005-12-12PDF 465.3 KB
External PhotosExternal Photos2005-12-12PDF 281.6 KB
Lable Location InfoID Label/Location Info2005-12-12PDF 109.5 KB
Test Setup PhotosTest Setup Photos2005-12-12PDF 169.2 KB
SAR Test ReportRF Exposure Info2005-12-12PDF 1.3 MB
Test ReportTest Report2005-12-12PDF 1.4 MB
Authorization LetterCover Letter(s)2005-12-12PDF 106.9 KB
Request For ConfidentialityCover Letter(s)2005-12-12PDF 140.7 KB
SAR Dipole Calibration DataRF Exposure Info2005-12-12PDF 1,019.9 KB
SAR Probe Calibration DataRF Exposure Info2005-12-12PDF 2.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 184.7 KB
Schematics Metadata onlySchematicsPDF 157.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 116 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 155.5 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 13 KB

Application Information

Application ID6E0tjlpOyKSAYIJbYB3z4g==
Final Action Date2005-12-12
Application PurposeOriginal Equipment
Applicant FRN0013981196
Model05M-1
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionTRI-BAND GSM 900/1800/1900 MHZ MOBILE PHONE
Responsible PartySergio Vizcaino, Technical Manager, sergio.vizcaino@i-mobil.com , 5255-5245-7366
AgentZhen Zhen Zhen, Morlab, xuezhen@morlab.cn , +86 0755 86130298
Test FirmXingsun Lin, ShenZhen Electronic Product Quality Testing Center, linxs@tsinghua.org.cn , 86-755-26703698
TCB Emailbrandhorst.dirk@phoenix-testlab.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is EIRP. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. This device contains GPRS (Class 10) functionalities. SAR compliance for body worn operating conditions must be restricted to belt clips and holsters that have no metallic component in the assembly and which maintain a minimum separation distance from the body of 1.5 cm. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are – Head: 0.132 W/kg; Body-worn: 0.058 W/kg.

Applications

Application IDDatePurpose
6E0tjlpOyKSAYIJbYB3z4g==2005-12-12Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz0.88300000.0189190000ppm300KGXW24E

Grants

TCB Grant - Application 6E0tjlpOyKSAYIJbYB3z4g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 12/12/2005

Application Dated: 12/12/2005
i-MOBIL S.A. DE C.V.
BOSQUE DE ALERCES No.12, MZ 43 LT 16,
COL.: BOSQUES DE LAS LOMAS, C.P.05120 CUAJIMAL
Mexico City, 05120
Mexico
 
Attention: Sergio Vizcaino , Technical Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  TPP05M-1
Name of Grantee:  i-MOBIL S.A. DE C.V.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: TRI-BAND GSM 900/1800/1900 MHZ MOBILE PHONE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.883 0.018919  PM 300KGXW

Power listed is EIRP. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. This device contains GPRS (Class 10) functionalities. SAR compliance for body worn operating conditions must be restricted to belt clips and holsters that have no metallic component in the assembly and which maintain a minimum separation distance from the body of 1.5 cm. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are – Head: 0.132 W/kg; Body-worn: 0.058 W/kg.

EAS Grant - Application 6E0tjlpOyKSAYIJbYB3z4g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

i-MOBIL S.A. DE C.V.
BOSQUE DE ALERCES No.12, MZ 43 LT 16, COL.: BOSQUES DE LAS LOMAS, C.P.05120 CUAJIMAL
Mexico City, 05120
Mexico
  Date of Grant: 12/12/2005

Application Dated: 12/12/2005
 
Attention: Sergio Vizcaino , Technical Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  TPP05M-1
Name of Grantee:  i-MOBIL S.A. DE C.V.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: TRI-BAND GSM 900/1800/1900 MHZ MOBILE PHONE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.883 0.018919  PM 300KGXW

Power listed is EIRP. This device contains 900/1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. This device contains GPRS (Class 10) functionalities. SAR compliance for body worn operating conditions must be restricted to belt clips and holsters that have no metallic component in the assembly and which maintain a minimum separation distance from the body of 1.5 cm. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are – Head: 0.132 W/kg; Body-worn: 0.058 W/kg.