GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA

Mikrotikls SIA Unlicensed National Information Infrastructure TX

FCC ID Filing: TV7GRV-A52HPN
Purchase on Amazon: Unlicensed National Information Infrastructure TX
Download: GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA
Document TypeRF Exposure Info
Document TitleRF Exposure

Document

Trouble Loading? Try GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA Downloading this document. Zoom In and Out With ⌘ / Ctrl key and plus [+] or minus [-]
Page 1 of GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA
Page 2 of GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA

RF Exposure Calculations
Mikrotik
MPE Calculator
Model: Groove A52HPn
Test Number:
MPE uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi.
dBi = dB gain compared to an isotropic radiator.
S = power density in mW/cm^2
Tx Frequency (MHz)
2437
Output Power
Maximum (Watts)
0.0
(dBm)
Cable Loss (dB)
170104
0.619441
Antenna Gain (dBi)
dBi to dBd
Antenna Gain (dBd)
24
2.2
21.83
27.9
Antenna minus cable (dBi)
24.00
Radiated (EIRP) dBm
51.920
Radiated (ERP) dBm
49.750
dBd + 2.17 = dBi
Calculated ERP (mw) 94406.088
Calculated EIRP (mw) 155596.563
EIRP = Po(dBM) + Gain (dB)
ERP = EIRP - 2.17 dB
Power density (S)
EIRP
------- = mW/cm^2
4 p r^2
EIRP (mW), r (cm)
FCC radio frequency radiation exposure limits per 1.1310
Occupational Limit
mW/cm2
50
W/m
General Public Limit
mW/cm2
10
W/m2
Frequency (MHz)
300-1,500
1,500-10,000
0.02619ƒ0.6834
5.40397
EIRP
milliwatts
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
155596.563
W/m2
Frequency (MHz)
Occupational Limit (W/m2 )
W/m2
General Public Limit
100-6,000
6,000-15,000
48-300
0.6455ƒ0.5
50
W/m2
W/m
300-6,000
6,000-15,000
mW/cm2
0.30955
0.40431
0.53592
0.55031
1.23820
1.52864
1.93468
2.20124
2.52693
2.93065
3.02294
3.11967
3.43944
4.09322
4.95279
6.11456
7.73874
W/m2
3.09550
4.04310
5.35924
5.50310
12.38198
15.28640
19.34685
22.01241
25.26935
29.30646
30.22945
31.19673
34.39439
40.93217
49.52792
61.14559
77.38738
47CFR 1.1310
RSS-102
Public Limit (W/m2 )
1.291
50
Distance
cm
200.00
175.00
152.00
150.00
100.00
90.00
80.00
75.00
70.00
65.00
64.00
63.00
60.00
55.00
50.00
45.00
40.00
Frequency (MHz)
Rogers Labs, Inc.
4405 W. 259th Terrace
Louisburg, KS 66053
Phone/Fax: (913) 837-3214
Revision 1
Public Limit (mW/cm2 )
f/1500
IC radio frequency radiation exposure limits per RSS-102
Occupational Limit
0.6455ƒ0.5
31.86574
Occupational Limit (mW/cm2 )
f/300
Occupational Limit minimum Distance
(meters)
0.63
0.63
0.02619ƒ
10
0.6834
Distance
meter
2.00
1.75
1.52
1.50
1.00
0.90
0.80
0.75
0.70
0.65
0.640
0.630
0.600
0.550
0.500
0.450
0.400
Distance
inches
78.74
68.90
59.84
59.06
39.37
35.43
31.50
29.53
27.56
25.59
25.20
24.80
23.62
21.65
19.69
17.72
15.75
Public Limit minimum distance (meters)
1.52
1.52
Mikrotikls SIA
S/N: 6F0406F1788D
Model: RBGrooveA-52HPn-US
FCC ID: TV7GRV-A52HPN
Test #: 170104
IC: 7442A-GRVA52HPN
Test to: 47CFR, 15.C, 15E, RSS-247 Date: May 9, 2017
File: RBGrooveA-52HPn RFExp
Page 1 of 2
Distance
Feet
6.56
5.74
4.99
4.92
3.28
2.95
2.62
2.46
2.30
2.13
2.10
2.07
1.97
1.80
1.64
1.48
1.31
Mikrotik
MPE Calculator
Model: Groove A52HPn
Test Number:
MPE uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi.
dBi = dB gain compared to an isotropic radiator.
S = power density in mW/cm^2
Tx Frequency (MHz)
5785
Output Power
Maximum (Watts)
0.0
(dBm)
Cable Loss (dB)
170104
0.080724
Antenna Gain (dBi)
dBi to dBd
Antenna Gain (dBd)
32
2.2
29.83
19.1
Antenna minus cable (dBi)
32.00
Radiated (EIRP) dBm
51.070
Radiated (ERP) dBm
48.900
dBd + 2.17 = dBi
Calculated ERP (mw) 77624.712
Calculated EIRP (mw) 127938.130
EIRP = Po(dBM) + Gain (dB)
ERP = EIRP - 2.17 dB
Power density (S)
EIRP
------- = mW/cm^2
4 p r^2
EIRP (mW), r (cm)
FCC radio frequency radiation exposure limits per 1.1310
Occupational Limit
50
mW/cm2
W/m
General Public Limit
Frequency (MHz)
300-1,500
1,500-10,000
mW/cm
W/m2
IC radio frequency radiation exposure limits per RSS-102
Occupational Limit
0.02619ƒ0.6834
9.75649
EIRP
milliwatts
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
127938.130
Public Limit (mW/cm2 )
f/1500
10
0.6455ƒ0.5
49.09621
Occupational Limit (mW/cm2 )
f/300
W/m2
Frequency (MHz)
Occupational Limit (W/m2 )
W/m2
General Public Limit
100-6,000
6,000-15,000
48-300
0.6455ƒ0.5
50
W/m2
W/m2
300-6,000
6,000-15,000
mW/cm2
0.25452
0.28202
0.31423
0.35228
0.39770
0.45249
0.51944
0.60243
0.70701
0.84140
0.95966
1.01810
1.80995
4.07240
4.81143
5.02765
6.36312
W/m2
2.54525
2.82022
3.14228
3.52283
3.97695
4.52489
5.19438
6.02426
7.07013
8.41404
9.59656
10.18099
18.09954
40.72397
48.11433
50.27651
63.63121
Frequency (MHz)
47CFR 1.1310
RSS-102
Rogers Labs, Inc.
4405 W. 259th Terrace
Louisburg, KS 66053
Phone/Fax: (913) 837-3214
Revision 1
Public Limit (W/m2 )
1.291
50
0.02619ƒ0.6834
10
Distance
cm
200.00
190.00
180.00
170.00
160.00
150.00
140.00
130.00
120.00
110.00
103.00
100.00
75.00
50.00
46.00
45.00
40.00
Distance
meter
2.00
1.90
1.80
1.70
1.60
1.50
1.40
1.30
1.20
1.10
1.030
1.000
0.750
0.500
0.460
0.450
0.400
Occupational Limit minimum Distance
(meters)
0.46
0.46
Distance
inches
78.74
74.80
70.87
66.93
62.99
59.06
55.12
51.18
47.24
43.31
40.55
39.37
29.53
19.69
18.11
17.72
15.75
Public Limit minimum distance (meters)
1.03
1.03
Mikrotikls SIA
S/N: 6F0406F1788D
Model: RBGrooveA-52HPn-US
FCC ID: TV7GRV-A52HPN
Test #: 170104
IC: 7442A-GRVA52HPN
Test to: 47CFR, 15.C, 15E, RSS-247 Date: May 9, 2017
File: RBGrooveA-52HPn RFExp
Page 2 of 2
Distance
Feet
6.56
6.23
5.91
5.58
5.25
4.92
4.59
4.27
3.94
3.61
3.38
3.28
2.46
1.64
1.51
1.48
1.31
Download: GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA
Mirror Download [FCC.gov]GRV-A52HPN Unlicensed National Information Infrastructure TX RF Exposure Info RF Exposure Mikrotikls SIA
Document ID3413493
Application ID/aMAfFkUjC9cRUI/uK7otg==
Document DescriptionRF Exposure
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize21.88kB (273448 bits)
Date Submitted2017-06-05 00:00:00
Date Available2017-06-05 00:00:00
Creation Date2017-05-09 13:30:17
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2017-05-09 13:30:17
Document TitleRF Exposure
Document CreatorMicrosoft® Word 2016

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : en-US
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2017:05:09 13:30:17-05:00
Modify Date                     : 2017:05:09 13:30:17-05:00
Document ID                     : uuid:32AC118D-9739-4358-A908-FA4E3777CDB5
Instance ID                     : uuid:32AC118D-9739-4358-A908-FA4E3777CDB5
Creator                         : Microsoft® Word 2016