FCC ID U72RVG00001

WiFi Control Box

by Carestream Health, Inc.

Grantee Code: U72   Product Code: RVG00001
Latest application date: 2010-04-15

FCC ID Device Details

FCC IDU72RVG00001
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeU72
Product CodeRVG00001
Applicant BusinessCarestream Health, Inc. 🇺🇸
Related Domains carestreamhealth.com
Equipment ClassWiFi Control Box
Test FirmLCIE

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2010-04-15

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2010-04-15PDF 4.1 MB
Manual - RegulatoryUsers Manual2010-04-15PDF 471.9 KB
Internal PhotosInternal Photos2010-04-15PDF 714.5 KB
External PhotosExternal Photos2010-04-15PDF 510.2 KB
Label and LocationID Label/Location Info2010-04-15PDF 508.2 KB
Test Setup PhotosTest Setup Photos2010-04-15PDF 567.6 KB
Test Report Part 1Test Report2010-04-15PDF 2.5 MB
Test Report Part 2Test Report2010-04-15PDF 2.3 MB
Attestation - Ad Hoc DeclarationCover Letter(s)2010-04-15PDF 22.7 KB
Attestation - No antenna connectorCover Letter(s)2010-04-15PDF 56.7 KB
Confidentiality RequestCover Letter(s)2010-04-15PDF 65.9 KB
RF Exposure InfoRF Exposure Info2010-04-15PDF 69 KB

Application Information

Application IDgnh7yMBibW1MV03+LlxbHA==
Final Action Date2010-04-15
Application PurposeOriginal Equipment
Applicant FRN0016195265
ModelRVG00001
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWiFi Control Box
Responsible PartyRonald Lee Cain, EMC Engineer, ronald.cain@carestreamhealth.com , 585-267-8321
Test FirmSandie Caudal, LCIE, sandie.caudal@lcie.fr , 00-33-1-40-95-62-28
TCB Emailcertification@curtis-straus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThis device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
gnh7yMBibW1MV03+LlxbHA==2010-04-15Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.043000015C20

Grants

TCB Grant - Application gnh7yMBibW1MV03+LlxbHA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 04/15/2010

Application Dated: 04/15/2010
Carestream Health, Inc.
150 Verona St.
Rochester, NY 14608
 
Attention: Ronald Cain , EMC Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U72RVG00001
Name of Grantee:  Carestream Health, Inc.
Equipment Class: Digital Transmission System
Notes: WiFi Control Box
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.043  

This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application gnh7yMBibW1MV03+LlxbHA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Carestream Health, Inc.
150 Verona St.
Rochester, NY 14608
United States
  Date of Grant: 04/15/2010

Application Dated: 04/15/2010
 
Attention: Ronald Cain , EMC Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U72RVG00001
Name of Grantee:  Carestream Health, Inc.
Equipment Class: Digital Transmission System
Notes: WiFi Control Box
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 15C 2412.0  -  2462.0 0.043  

This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: