FCC ID U7XMC-6500S

Portable Data Collection Terminal

by M3 Mobile Co., Ltd

Grantee Code: U7X   Product Code: MC6500S
Latest application date: 2007-07-06

FCC ID Device Details

FCC IDU7XMC-6500S
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeU7X
Product CodeMC6500S
Applicant BusinessM3 Mobile Co., Ltd 🇰🇷
Related Domains m3mobile.co.kr
Equipment ClassPortable Data Collection Terminal
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2007-07-06
2402-2480 MHzOriginal Equipment2007-07-06
824.2-848.8 MHzOriginal Equipment2007-07-06

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2007-08-20PDF 3.3 MB
Internal PhotosInternal Photos2007-08-20PDF 1.1 MB
External PhotosExternal Photos2007-08-20PDF 280 KB
ID Label LocationID Label/Location Info2007-07-06PDF 70.3 KB
ID Label Location InfoID Label/Location Info2007-07-06PDF 70.3 KB
Test Setup PhotosTest Setup Photos2007-08-20PDF 252.7 KB
SAR Test Setup PhotosRF Exposure Info2007-07-06PDF 1.2 MB
Annex to Test ReportTest Report2007-07-06PDF 350.2 KB
SAR Report Part IRF Exposure Info2007-07-06PDF 1.7 MB
SAR Report Part IIRF Exposure Info2007-07-06PDF 1.5 MB
SAR Report Part IIIRF Exposure Info2007-07-06PDF 2.8 MB
Test ReportTest Report2007-07-06PDF 1 MB
Test ReportTest Report2007-07-06PDF 1.4 MB
Test Report BTTest Report2007-07-06PDF 1.7 MB
Attestation StatementAttestation Statements2007-07-06PDF 13.3 KB
Attestation StatementAttestation Statements2007-07-06PDF 12.1 KB
Authorization LetterCover Letter(s)2007-07-06PDF 13.3 KB
Declaration RF Exposure Waring StatementCover Letter(s)2007-07-06PDF 15.4 KB
Declaration ad hoc mode functionCover Letter(s)2007-07-06PDF 21.6 KB
Request for ConfidentialityCover Letter(s)2007-07-06PDF 18.8 KB

Application Information

Application IDrI7zhBvDJjsEAZ3Biikl7g==
Final Action Date2007-07-06
Application PurposeOriginal Equipment
Applicant FRN0018849257
ModelMC-6500S
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPortable Data Collection Terminal
Responsible PartyYeo Chan Yun, sy0317@m3mobile.co.kr , 82-2-2022-1312
AgentSung-Ko Sung-Ko Sung-Ko, HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES C, skhong@hct.co.kr , 82-31-639-8518
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB EmailBentje.Holger@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Short-Term Confidentiality Date08/20/2007
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.595 W/kg.

Applications

Application IDDatePurpose
rI7zhBvDJjsEAZ3Biikl7g==2007-07-06Original Equipment
WDTVl5fUHmSaW/f+8dU2Hw==2007-07-06Original Equipment
OBk636Om1qEgI58cjF4DmA==2007-07-06Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.2742.5ppm300KGXW22H
824.2-848.8 MHz0.1522.5ppm300KG7W22H
1850.2-1909.8 MHz0.3562.5ppm300KGXW24E
1850.2-1909.8 MHz0.1842.5ppm300KG7W24E
2402-2480 MHz0.001890015C
2412-2462 MHz0.034100015C

Grants

TCB Grant - Application WDTVl5fUHmSaW/f+8dU2Hw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 07/06/2007

Application Dated: 07/06/2007
M3 Mobile Co., Ltd
M3 B/D , 735-45 , Yeoksam-dong , Gangnam-gu
Seoul,
South Korea
 
Attention: Yeo Chan Yun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U7XMC-6500S
Name of Grantee:  M3 Mobile Co., Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Portable Data Collection Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00189  

Power listed is conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.595 W/kg.

EAS Grant - Application WDTVl5fUHmSaW/f+8dU2Hw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

M3 Mobile Co., Ltd
M3 B/D , 735-45 , Yeoksam-dong , Gangnam-gu
Seoul,
South Korea
  Date of Grant: 07/06/2007

Application Dated: 07/06/2007
 
Attention: Yeo Chan Yun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U7XMC-6500S
Name of Grantee:  M3 Mobile Co., Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Portable Data Collection Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00189  

Power listed is conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.595 W/kg.



Mail To:


EA826490

TCB Grant - Application rI7zhBvDJjsEAZ3Biikl7g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 07/06/2007

Application Dated: 07/06/2007
M3 Mobile Co., Ltd
M3 B/D , 735-45 , Yeoksam-dong , Gangnam-gu
Seoul,
South Korea
 
Attention: Yeo Chan Yun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U7XMC-6500S
Name of Grantee:  M3 Mobile Co., Ltd
Equipment Class: Digital Transmission System
Notes: Portable Data Collection Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0341  

Power listed is conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.595 W/kg.


EAS Grant - Application rI7zhBvDJjsEAZ3Biikl7g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

M3 Mobile Co., Ltd
M3 B/D , 735-45 , Yeoksam-dong , Gangnam-gu
Seoul,
South Korea
  Date of Grant: 07/06/2007

Application Dated: 07/06/2007
 
Attention: Yeo Chan Yun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U7XMC-6500S
Name of Grantee:  M3 Mobile Co., Ltd
Equipment Class: Digital Transmission System
Notes: Portable Data Collection Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.0341  

Power listed is conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation distance between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Body-worn: 0.595 W/kg.



Mail To:


EA135844

TCB Grant - Application OBk636Om1qEgI58cjF4DmA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 07/06/2007

Application Dated: 07/06/2007
M3 Mobile Co., Ltd
M3 B/D , 735-45 , Yeoksam-dong , Gangnam-gu
Seoul,
South Korea
 
Attention: Yeo Chan Yun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U7XMC-6500S
Name of Grantee:  M3 Mobile Co., Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Portable Data Collection Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.274 2.5  PM 300KGXW
24E 1850.2  -  1909.8 0.356 2.5  PM 300KGXW
22H 824.2  -  848.8 0.152 2.5  PM 300KG7W
24E 1850.2  -  1909.8 0.184 2.5  PM 300KG7W

Power listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating configurations is limited to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.141 W/kg, Body: 0.022 W/kg; Part 22 - Head: 0.199 W/kg, Body: 0.046 W/kg

EAS Grant - Application OBk636Om1qEgI58cjF4DmA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

M3 Mobile Co., Ltd
M3 B/D , 735-45 , Yeoksam-dong , Gangnam-gu
Seoul,
South Korea
  Date of Grant: 07/06/2007

Application Dated: 07/06/2007
 
Attention: Yeo Chan Yun

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U7XMC-6500S
Name of Grantee:  M3 Mobile Co., Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Portable Data Collection Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.274 2.5  PM 300KGXW
24E 1850.2  -  1909.8 0.356 2.5  PM 300KGXW
22H 824.2  -  848.8 0.152 2.5  PM 300KG7W
24E 1850.2  -  1909.8 0.184 2.5  PM 300KG7W

Power listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating configurations is limited to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.141 W/kg, Body: 0.022 W/kg; Part 22 - Head: 0.199 W/kg, Body: 0.046 W/kg