FCC ID U88-ICELITETNR33

ICS RF Repeater

by GS Instech Co., Ltd.

Grantee Code: U88   Product Code: ICELITETNR33
Latest application date: 2019-06-18

FCC ID Device Details

FCC IDU88-ICELITETNR33
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeU88
Product CodeICELITETNR33
Applicant BusinessGS Instech Co., Ltd. 🇰🇷
Related Domains gsinstrument.com
Equipment ClassICS RF Repeater
Test FirmHCT Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2496.3-2690 MHzOriginal Equipment2019-06-18

Exhibits

DocumentTypeAvailableFile
User manual_F_rev.1Users Manual2019-12-15PDF 4 MB
Internal Photos_20190605_v1 - IC-ELITE TNR33 Internal PhotosInternal Photos2019-12-15PDF 1.3 MB
External Photos_20190605_v1 - IC-ELITE TNR33 External PhotosExternal Photos2019-12-15PDF 839.4 KB
ID Label & Location Info._20190605_v1 - FCC label & locationID Label/Location Info2019-06-18PDF 569 KB
Test Setup Photos_20190605_v1 - IC-ELITE TNR33 Annex A. EUT and Test Setup PhotoTest Setup Photos2019-12-15PDF 1 MB
IC-ELITE TNR33 Test Report_Rev02_part1Test Report2019-06-18PDF 5.1 MB
IC-ELITE TNR33 Test Report_Rev02_part2Test Report2019-06-18PDF 5.3 MB
Test Report_20190605_v1 - IC-ELITE TNR33_RF EXPOSURE ReportRF Exposure Info2019-06-18PDF 720.9 KB
Attestation letter for Warning Label Message_Part20Cover Letter(s)2019-06-18PDF 326.1 KB
Confidentiality LetterCover Letter(s)2019-06-18PDF 668.5 KB
FCC_Authorization LetterCover Letter(s)2019-06-18PDF 215.7 KB
Block Diagrams_20190605_v1 - Block diagram Metadata onlyBlock DiagramPDF 100.6 KB
Schematics_20190605_v1 - Circuit diagram_F Metadata onlySchematicsPDF 2.9 MB
Operational description_rev.1 Metadata onlyOperational DescriptionPDF 1.5 MB
Parts List & Tune Up Info._20190605_v1 - Part list_F Metadata onlyParts List/Tune Up InfoPDF 657.8 KB
Parts List & Tune Up Info._20190605_v1 - Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 2.6 MB

Application Information

Application ID4s8u3rVHzDvsDTLi4oqPkw==
Final Action Date2019-06-18
Application PurposeOriginal Equipment
Applicant FRN0016367252
ModelICELITETNR33
Frequency Range2496.3-2690 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionICS RF Repeater
Responsible PartyGuanyong Jung, jky0514@gsinstrument.com , +82328705525
Test FirmLee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr , 82-31-645-6432
TCB EmailLST.FRE.CertNotice@ul.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/15/2019
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. Device supports Max. 60 MHz (20MHz X 3 carrier) for 4G LTE and Max. 60 MHz (60 MHz X 1 carrier) for 5G NR(New Radio). This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. The antenna gain for antennas used with this booster should not exceed 21dBi and the antennas should be installed with a separation distance of 120cm from all persons during normal use. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

Applications

Application IDDatePurpose
4s8u3rVHzDvsDTLi4oqPkw==2019-06-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
2496.3-2690 MHz1.253AmpG7W27
2496.3-2690 MHz1.164AmpG7W27

Grants

TCB Grant - Application 4s8u3rVHzDvsDTLi4oqPkw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 06/18/2019

Application Dated: 06/17/2019
GS Instech Co., Ltd.
1385-14, Juan-Dong, Nam-Ku
Incheon, 402-200
South Korea
 
Attention: Guanyong Jung

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U88-ICELITETNR33
Name of Grantee:  GS Instech Co., Ltd.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: ICS RF Repeater
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2496.3  -  2690.0 1.253  Amp G7W
27 2496.3  -  2690.0 1.164  Amp G7W

Output power is conducted. Device supports Max. 60 MHz (20MHz X 3 carrier) for 4G LTE and Max. 60 MHz (60 MHz X 1 carrier) for 5G NR(New Radio). This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. The antenna gain for antennas used with this booster should not exceed 21dBi and the antennas should be installed with a separation distance of 120cm from all persons during normal use. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

EAS Grant - Application 4s8u3rVHzDvsDTLi4oqPkw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

GS Instech Co., Ltd.
1385-14, Juan-Dong, Nam-Ku
Incheon, 402-200
South Korea
  Date of Grant: 06/18/2019

Application Dated: 06/17/2019
 
Attention: Guanyong Jung

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  U88-ICELITETNR33
Name of Grantee:  GS Instech Co., Ltd.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: ICS RF Repeater
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2496.3  -  2690.0 1.253  Amp G7W
27 2496.3  -  2690.0 1.164  Amp G7W

Output power is conducted. Device supports Max. 60 MHz (20MHz X 3 carrier) for 4G LTE and Max. 60 MHz (60 MHz X 1 carrier) for 5G NR(New Radio). This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. The antenna gain for antennas used with this booster should not exceed 21dBi and the antennas should be installed with a separation distance of 120cm from all persons during normal use. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.



Mail To: