FCC ID U88-SC-8924AMP
In-Building Repeater
by GS Instech Co., Ltd.
Grantee Code: U88 Product Code: SC8924AMP
Latest application date: 2011-05-24
FCC ID Device Details
| FCC ID | U88-SC-8924AMP |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | U88 |
| Product Code | SC8924AMP |
| Applicant Business | GS Instech Co., Ltd. 🇰🇷 |
| Related Domains | |
| Equipment Class | In-Building Repeater |
| Test Firm | HCT Co., LTD |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 806-824 MHz | Original Equipment | 2011-05-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2011-07-08 | PDF 4 MB |
| internal Photo | Internal Photos | 2011-07-08 | PDF 1.8 MB |
| External Photo | External Photos | 2011-07-08 | PDF 390.6 KB |
| label | ID Label/Location Info | 2011-05-24 | PDF 114.3 KB |
| RF Setup Photo | Test Setup Photos | 2011-07-08 | PDF 414 KB |
| Report 1 of 3 | Test Report | 2011-05-24 | PDF 1.9 MB |
| Report 2 of 3 | Test Report | 2011-05-24 | PDF 4.3 MB |
| DoC Attestation Letter | Attestation Statements | 2011-05-24 | PDF 377.7 KB |
| Authorization letter | Cover Letter(s) | 2011-05-24 | PDF 81.9 KB |
| confidential Letter | Cover Letter(s) | 2011-05-24 | PDF 71.3 KB |
| Rf Exposure | RF Exposure Info | 2011-05-24 | PDF 214.6 KB |
Application Information
| Application ID | Qopb13A1pr4gVpLLfFeKRg== |
|---|---|
| Final Action Date | 2011-05-24 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0016367252 |
| Model | -SC-8924AMP |
| Frequency Range | 806-824 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | In-Building Repeater |
| Responsible Party | Youngil Kim, kyi@gsinstrument.com |
| Test Firm | Sang Lee, HCT Co., LTD, sjlee@HCT.co.kr |
| TCB Email | tcb@siemic.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/08/2011 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Dual Band IDEN RF Repeater. Power Output is maximum single channel conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Approval is for maximum gain 12.0 dBi antennas as shown in this filing. Installations with higher gain or co-located antennas require RF exposure to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Qopb13A1pr4gVpLLfFeKRg== | 2011-05-24 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application Qopb13A1pr4gVpLLfFeKRg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Siemic Inc. 775 Montague Expressway Milpitas, CA 95035 |
Date of Grant: 05/24/2011 Application Dated: 05/24/2011 |
| GS Instruments Co., Ltd. |
| 1385-14, Juan-Dong, Nam-Ku |
| Incheon, 402-200 South Korea |
| Attention: Youngil Kim |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U88-SC-8924AMP |
| Name of Grantee: | GS Instruments Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | In-Building Repeater |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 851.0 - 869.0 | 0.1261 | Amp | GXW | |
| 90 | 862.0 - 869.0 | 0.1264 | Amp | GXW | |
| 90 | 935.0 - 940.0 | 0.1273 | Amp | GXW | |
| 90 | 806.0 - 824.0 | 0.1261 | Amp | GXW | |
| 90 | 817.0 - 824.0 | 0.1291 | Amp | GXW | |
| 90 | 896.0 - 901.0 | 0.128 | Amp | GXW |
| Dual Band IDEN RF Repeater. Power Output is maximum single channel conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Approval is for maximum gain 12.0 dBi antennas as shown in this filing. Installations with higher gain or co-located antennas require RF exposure to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
EAS Grant - Application Qopb13A1pr4gVpLLfFeKRg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GS Instruments Co., Ltd. 1385-14, Juan-Dong, Nam-Ku Incheon, 402-200 South Korea |
Date of Grant: 05/24/2011 Application Dated: 05/24/2011 |
| Attention: Youngil Kim |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U88-SC-8924AMP |
| Name of Grantee: | GS Instruments Co., Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | In-Building Repeater |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 851.0 - 869.0 | 0.1261 | Amp | GXW | |
| 90 | 862.0 - 869.0 | 0.1264 | Amp | GXW | |
| 90 | 935.0 - 940.0 | 0.1273 | Amp | GXW | |
| 90 | 806.0 - 824.0 | 0.1261 | Amp | GXW | |
| 90 | 817.0 - 824.0 | 0.1291 | Amp | GXW | |
| 90 | 896.0 - 901.0 | 0.128 | Amp | GXW |
| Dual Band IDEN RF Repeater. Power Output is maximum single channel conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Approval is for maximum gain 12.0 dBi antennas as shown in this filing. Installations with higher gain or co-located antennas require RF exposure to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
| Mail To: |