FCC ID U9AMD57A
IPC MD-57A
by Siemens AG
Grantee Code: U9A Product Code: MD57A
Latest application date: 2025-03-27
FCC ID Device Details
| FCC ID | U9AMD57A |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | U9A |
| Product Code | MD57A |
| Applicant Business | Siemens AG 🇩🇪 |
| Related Domains | |
| Equipment Class | IPC MD-57A |
| Test Firm | Verkotan Oy |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 6025-6985 MHz | Class II permissive change or modification of presently authorized equipment | 2025-03-27 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2025-03-26 |
| 5855 MHz | Class II permissive change or modification of presently authorized equipment | 2025-03-26 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2025-03-26 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 09/09/2021 | 2024-11-20 |
| 5955-7115 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 11/08/2021 | 2024-11-20 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 08/24/2022 | 2024-11-20 |
| 2402-2480 MHz | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 09/09/2021 | 2024-11-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2025-09-17 | PDF 4.5 MB |
| Internal Photos | Internal Photos | 2025-09-17 | PDF 233.6 KB |
| External Photos | External Photos | 2025-09-17 | PDF 671 KB |
| External photographs | External Photos | 2024-11-20 | PDF 3.1 MB |
| External photographs | External Photos | 2024-11-20 | PDF 871.2 KB |
| ID Label/Location Info | ID Label/Location Info | 2025-03-27 | PDF 210.9 KB |
| Label information | ID Label/Location Info | 2024-11-20 | PDF 871.2 KB |
| Test Setup Photos | Test Setup Photos | 2025-03-27 | PDF 295.2 KB |
| Antenna specification | Test Report | 2025-03-27 | PDF 648.5 KB |
| Test Report_SAR | RF Exposure Info | 2025-03-27 | PDF 5.4 MB |
| Attestation Statements | Attestation Statements | 2025-03-27 | PDF 180.2 KB |
| US Agent letter | Attestation Statements | 2025-03-27 | PDF 186 KB |
| Updated AgentLetter | Attestation Statements | 2025-03-27 | PDF 27.7 KB |
| Covered list attestation | Attestation Statements | 2024-11-20 | PDF 179.1 KB |
| Designation of US agent for service of process | Attestation Statements | 2024-11-20 | PDF 188.9 KB |
| Confidentiality | Cover Letter(s) | 2025-03-27 | PDF 83.4 KB |
| Declaration of authorization | Cover Letter(s) | 2025-03-27 | PDF 69.8 KB |
| FCC Class II permissive change letter | Cover Letter(s) | 2025-03-27 | PDF 88.1 KB |
| Agent authorization letter | Cover Letter(s) | 2024-11-20 | PDF 69.8 KB |
| Application cover letter | Cover Letter(s) | 2024-11-20 | PDF 20.3 KB |
| Change of ID authorization letter | Cover Letter(s) | 2024-11-20 | PDF 92.4 KB |
| FCC Auth Ltr for Change of ID_SIEMENS_AX411NGW_U9AMD57A_rev1 | Cover Letter(s) | 2024-11-20 | PDF 92.4 KB |
| Block Diagram Metadata only | Block Diagram | PDF 1.4 MB | |
| Schematics Metadata only | Schematics | PDF 3.1 MB | |
| Operational Description Metadata only | Operational Description | PDF 707.9 KB |
Application Information
| Application ID | 6W1UZNc5XXJoc/IKuU0EUw== |
|---|---|
| Final Action Date | 2025-03-27 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0016367492 |
| Model | MD57A |
| Frequency Range | 6025-6985 MHz |
| Equipment Class | 6XD - 15E 6 GHz Low Power Indoor Client |
| Device Description | IPC MD-57A |
| Responsible Party | Juergen Meier, Standardization and Regulations Engineer, juergen.meier@siemens.com |
| Agent | Melanie Melanie Melanie, 7layers GmbH, melanie.anastassiou@bureauveritas.com |
| Technical Contact | Juergen Meier, Siemens AG, juergen.meier@siemens.com |
| Non-Technical Contact | Juergen Meier, Siemens AG, juergen.meier@siemens.com |
| Test Firm | Miia Nurkkala, Verkotan Oy, miia.nurkkala@verkotan.com |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 09/17/2025 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | C2PC: Add the SAR measurements tested under the host: SIMATIC IPC MD-57A and reported under reference: FCC ISED RF Exposure Report_Industrial Notebook_ID7405_27012025 from Verkotan Oy issued on 27/01/2025. The highest reported Body and Simultaneous SAR values are 0.26 W/kg and 0.22 W/kg respectively. Power Output listed is Conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. This module is approved in portable/mobile configurations with antenna Intel Antenna, Type PIFA at 15mm minimum test separation distance. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 6W1UZNc5XXJoc/IKuU0EUw== | 2025-03-27 | Class II permissive change or modification of presently authorized equipment |
| rBbSOWDFHjk/V3wgGUNPtg== | 2025-03-26 | Class II permissive change or modification of presently authorized equipment |
| rB6Y7+Uk5X3ahJJ+g4jkpA== | 2025-03-26 | Class II permissive change or modification of presently authorized equipment |
| Nf7UqWD62JZ3KhXFzoeztg== | 2025-03-26 | Class II permissive change or modification of presently authorized equipment |
| ywJUb74BtMuXYc511OMSYw== | 2024-11-20 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 09/09/2021 |
| xdbDd+UKCcBSQeiGwUaucg== | 2024-11-20 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 11/08/2021 |
| qWXWRUEYrJ5TwRMb6OQWdQ== | 2024-11-20 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 09/09/2021 |
| q+/2gbfCIq+I5OgNTcXx3A== | 2024-11-20 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 08/24/2022 |
| fOqVRX7W4J1kLai8VxnfDQ== | 2024-11-20 | Change in identification of presently authorized equipment. Original FCC ID: PD9AX411NG Grant Date: 09/09/2021 |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 15B | CC | ||
| 2402-2480 MHz | 0.011 | 15C | CC |
| 2402-2480 MHz | 0.0150000 | 15C | CC |
| 2402-2480 MHz | 0.011 | CC | |
| 2402-2480 MHz | 0.0150000 | CC | |
| 2412-2472 MHz | 0.975 | 15C | CC, MO |
| 2412-2472 MHz | 0.975 | CC, MO | |
| 2422-2462 MHz | 0.64 | 15C | CC, MO |
| 2422-2462 MHz | 0.64 | CC, MO | |
| 5210 MHz | 0.09 | 15E | CC, MO |
| 5210 MHz | 0.09 | CC, MO | |
| 5250 MHz | 0.069 | 15E | CC, MO |
| 5250 MHz | 0.069 | CC, MO | |
| 5260-5320 MHz | 0.143 | 15E | CC, MO, ND |
| 5260-5320 MHz | 0.143 | CC, MO, ND | |
| 5270-5310 MHz | 0.182 | 15E | CC, MO, ND |
| 5270-5310 MHz | 0.182 | CC, MO, ND | |
| 5290 MHz | 0.08 | 15E | CC, MO, ND |
| 5290 MHz | 0.08 | CC, MO, ND | |
| 5500-5700 MHz | 0.141 | 15E | CC, MO, ND |
| 5500-5700 MHz | 0.141 | CC, MO, ND | |
| 5510-5670 MHz | 0.237 | 15E | CC, MO, ND |
| 5510-5670 MHz | 0.237 | CC, MO, ND | |
| 5530-5690 MHz | 0.231 | 15E | CC, MO, ND |
| 5530-5690 MHz | 0.231 | CC, MO, ND | |
| 5570 MHz | 0.138 | 15E | CC, MO, ND |
| 5570 MHz | 0.138 | CC, MO, ND | |
| 5710 MHz | 0.223 | 15E | CC, MO, ND |
| 5710 MHz | 0.223 | CC, MO, ND | |
| 5720 MHz | 0.137 | 15E | CC, MO, ND |
| 5720 MHz | 0.137 | CC, MO, ND | |
| 5745-5825 MHz | 0.233 | 15E | CC, MO |
| 5745-5825 MHz | 0.233 | CC, MO | |
| 5755-5795 MHz | 0.243 | 15E | CC, MO |
| 5755-5795 MHz | 0.243 | CC, MO | |
| 5775 MHz | 0.187 | 15E | CC, MO |
| 5775 MHz | 0.187 | CC, MO | |
| 5815 MHz | 0.195 | 15E | CC, MO |
| 5815 MHz | 0.195 | CC, MO | |
| 5835-5875 MHz | 0.693 | 15E | CC, MO |
| 5835-5875 MHz | 0.693 | CC, MO | |
| 5845-5885 MHz | 0.28 | 15E | CC, MO |
| 5845-5885 MHz | 0.28 | CC, MO | |
| 5855 MHz | 0.693 | 15E | CC, MO |
| 5855 MHz | 0.693 | CC, MO | |
| 5955-7115 MHz | 0.003 | 15E | CC, MO |
| 5965-7085 MHz | 0.007 | 15E | CC, MO |
| 5965-7085 MHz | 0.007 | CC, MO | |
| 5985-7025 MHz | 0.012 | 15E | CC, MO |
| 5985-7025 MHz | 0.012 | CC, MO | |
| 5995-7115 MHz | 0.003 | CC, MO | |
| 6025-6985 MHz | 0.021 | 15E | CC, MO |
| 6025-6985 MHz | 0.021 | CC, MO |
Grants
TCB Grant - Application ywJUb74BtMuXYc511OMSYw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| P.O. Box 1963, |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.015 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.03W/kg and 1.28W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application ywJUb74BtMuXYc511OMSYw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Werner-von-Siemens-Str. 50 P.O. Box 1963, Amberg, 92224 Germany |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.015 |
| Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.03W/kg and 1.28W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| P.O. Box 1963, |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5955.0 - 7115.0 | 0.003 | ||
| CC MO | 15E | 5965.0 - 7085.0 | 0.007 | ||
| CC MO | 15E | 5985.0 - 7025.0 | 0.012 | ||
| CC MO | 15E | 6025.0 - 6985.0 | 0.021 |
| Power Output listed is Conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.26 W/kg and 0.74 W/kg respectively. This module is approved in portable/mobile configurations with antenna Intel Antenna, Type PIFA at 15mm minimum test separation distance. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application xdbDd+UKCcBSQeiGwUaucg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Werner-von-Siemens-Str. 50 P.O. Box 1963, Amberg, 92224 Germany |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5955.0 - 7115.0 | 0.003 | ||
| CC MO | 15E | 5965.0 - 7085.0 | 0.007 | ||
| CC MO | 15E | 5985.0 - 7025.0 | 0.012 | ||
| CC MO | 15E | 6025.0 - 6985.0 | 0.021 |
| Power Output listed is Conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. The highest reported Body and Simultaneous SAR values are 0.26 W/kg and 0.74 W/kg respectively. This module is approved in portable/mobile configurations with antenna Intel Antenna, Type PIFA at 15mm minimum test separation distance. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 03/26/2025 Application Dated: 03/26/2025 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.015 |
| C2PC: Add the SAR measurements tested under the host: SIMATIC IPC MD-57A and reported under reference: FCC ISED RF Exposure Report_Industrial Notebook_ID7405_27012025 from Verkotan Oy issued on 27/01/2025. The highest reported Body and Simultaneous SAR values are <0.1 W/kg and 0.22 W/kg respectively. Â Power Output listed is conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. Â This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. Â SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application rB6Y7+Uk5X3ahJJ+g4jkpA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 03/26/2025 Application Dated: 03/26/2025 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.144 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.184 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.09 | ||
| CC MO | 15E | 5250.0 - 5250.0 | 0.069 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.143 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.182 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.08 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.141 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.237 | ||
| CC MO ND | 15E | 5570.0 - 5570.0 | 0.138 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.223 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.137 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.231 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.233 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.243 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.187 | ||
| CC MO | 15E | 5845.0 - 5885.0 | 0.28 | ||
| CC MO | 15E | 5835.0 - 5875.0 | 0.693 | ||
| CC MO | 15E | 5855.0 - 5855.0 | 0.693 | ||
| CC MO | 15E | 5815.0 - 5815.0 | 0.195 |
| C2PC: Add the SAR measurements tested under the host: SIMATIC IPC MD-57A and reported under reference: FCC ISED RF Exposure Report_Industrial Notebook_ID7405_27012025 from Verkotan Oy issued on 27/01/2025. The highest reported Body and Simultaneous SAR values are 0.14 W/kg and 0.22 W/kg respectively. Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
TCB Grant - Application qWXWRUEYrJ5TwRMb6OQWdQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| P.O. Box 1963, |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application qWXWRUEYrJ5TwRMb6OQWdQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Werner-von-Siemens-Str. 50 P.O. Box 1963, Amberg, 92224 Germany |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| P.O. Box 1963, |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.144 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.184 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.09 | ||
| CC MO | 15E | 5250.0 - 5250.0 | 0.069 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.143 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.182 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.08 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.141 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.237 | ||
| CC MO ND | 15E | 5570.0 - 5570.0 | 0.138 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.223 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.137 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.231 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.233 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.243 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.187 | ||
| CC MO | 15E | 5845.0 - 5885.0 | 0.28 | ||
| CC MO | 15E | 5835.0 - 5875.0 | 0.693 | ||
| CC MO | 15E | 5855.0 - 5855.0 | 0.693 | ||
| CC MO | 15E | 5815.0 - 5815.0 | 0.195 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.48W/kg and 1.28W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application q+/2gbfCIq+I5OgNTcXx3A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Werner-von-Siemens-Str. 50 P.O. Box 1963, Amberg, 92224 Germany |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.144 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.184 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.09 | ||
| CC MO | 15E | 5250.0 - 5250.0 | 0.069 | ||
| CC MO ND | 15E | 5260.0 - 5320.0 | 0.143 | ||
| CC MO ND | 15E | 5270.0 - 5310.0 | 0.182 | ||
| CC MO ND | 15E | 5290.0 - 5290.0 | 0.08 | ||
| CC MO ND | 15E | 5500.0 - 5700.0 | 0.141 | ||
| CC MO ND | 15E | 5510.0 - 5670.0 | 0.237 | ||
| CC MO ND | 15E | 5570.0 - 5570.0 | 0.138 | ||
| CC MO ND | 15E | 5710.0 - 5710.0 | 0.223 | ||
| CC MO ND | 15E | 5720.0 - 5720.0 | 0.137 | ||
| CC MO ND | 15E | 5530.0 - 5690.0 | 0.231 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.233 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.243 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.187 | ||
| CC MO | 15E | 5845.0 - 5885.0 | 0.28 | ||
| CC MO | 15E | 5835.0 - 5875.0 | 0.693 | ||
| CC MO | 15E | 5855.0 - 5855.0 | 0.693 | ||
| CC MO | 15E | 5815.0 - 5815.0 | 0.195 |
| Power Output listed is conducted. Modular Approval. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance, or a new application. This transmitter has 20MHz, 40MHz, 80MHz bandwidth modes as described in this filing. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.48W/kg and 1.28W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 03/26/2025 Application Dated: 03/26/2025 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Digital Transmission System |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.011 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.975 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.64 |
| C2PC: Add the SAR measurements tested under the host: SIMATIC IPC MD-57A and reported under reference: FCC ISED RF Exposure Report_Industrial Notebook_ID7405_27012025 from Verkotan Oy issued on 27/01/2025. The highest reported Body and Simultaneous SAR values are 0.01 W/kg and 0.22 W/kg respectively. Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance,or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application fOqVRX7W4J1kLai8VxnfDQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| P.O. Box 1963, |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Digital Transmission System |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.011 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.975 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.64 |
| Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance,or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.39W/kg and 1.28W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application fOqVRX7W4J1kLai8VxnfDQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Siemens AG Werner-von-Siemens-Str. 50 P.O. Box 1963, Amberg, 92224 Germany |
Date of Grant: 11/20/2024 Application Dated: 11/12/2024 |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | Digital Transmission System |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.011 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.975 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.64 |
| Power Output listed is conducted. Modular Approval. Power output has been reduced at the upper bandedge channels as shown in filings under this FCC ID. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. This module is approved in mobile/portable configurations. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Grantee must coordinate with OEM integrator to determine applicable host configurations to ensure RF exposure compliance, including simultaneous transmission SAR requirements according to published KDB 616217 Supplement documentation. When all conditions of this filing cannot be met installation of this device into specific final products may require the submission of a permissive change application, containing appropriate data demonstrating compliance,or a new application. OEM/Host integrator must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. Device is a client only device containing a 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. OEM/Host integrator is responsible for complying with the instructions and requirements for each transmitter they choose to integrate into a host product. The highest reported Body and Simultaneous SAR values are 0.39W/kg and 1.28W/kg respectively. This module is approved in portable/mobile configurations with antenna SkyCross reference Antenna, Type PIFA at 15mm minimum test separation distance. SAR testing was performed to demonstrate RF compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Kiwa Nederland B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 03/27/2025 Application Dated: 03/27/2025 |
| Siemens AG |
| Werner-von-Siemens-Str. 50 |
| Amberg, 92224 Germany |
| Attention: Juergen Meier , Standardization and Regulations Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | U9AMD57A |
| Name of Grantee: | Siemens AG |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | IPC MD-57A |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5995.0 - 7115.0 | 0.003 | ||
| CC MO | 15E | 5965.0 - 7085.0 | 0.007 | ||
| CC MO | 15E | 5985.0 - 7025.0 | 0.012 | ||
| CC MO | 15E | 6025.0 - 6985.0 | 0.021 |
| C2PC: Add the SAR measurements tested under the host: SIMATIC IPC MD-57A and reported under reference: FCC ISED RF Exposure Report_Industrial Notebook_ID7405_27012025 from Verkotan Oy issued on 27/01/2025. The highest reported Body and Simultaneous SAR values are 0.26 W/kg and 0.22 W/kg respectively. Power Output listed is Conducted. Modular Approval filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. This module is approved in portable/mobile configurations with antenna Intel Antenna, Type PIFA at 15mm minimum test separation distance. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device supports 20, 40, 80 and 160 MHz BW modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |