FCC ID UCC-WA8011N

A8-Ein Super WiFi Base Station

by Altai Technologies Limited

Grantee Code: UCC   Product Code: WA8011N
Latest application date: 2013-03-21

FCC ID Device Details

FCC IDUCC-WA8011N
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeUCC
Product CodeWA8011N
Applicant BusinessAltai Technologies Limited
Related Domains altaitechnologies.com
Equipment ClassA8-Ein Super WiFi Base Station
Test FirmAudix Technology (Shenzhen) Co.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2013-03-21

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2013-03-21PDF 4 MB
Internal PhotosInternal Photos2013-03-21PDF 1.4 MB
External PhotosExternal Photos2013-03-21PDF 88.4 KB
Label and LocationID Label/Location Info2013-03-21PDF 180.6 KB
Test Setup PhotosTest Setup Photos2013-03-21PDF 113.6 KB
DoC ReportTest Report2013-03-21PDF 2.1 MB
Test Report DTS 1Test Report2013-03-21PDF 3.7 MB
Test Report DTS 2Test Report2013-03-21PDF 3.1 MB
Test Report DTS 3Test Report2013-03-21PDF 3.3 MB
Test Report DTS 4Test Report2013-03-21PDF 3.3 MB
Test Report DTS 5GHz 1Test Report2013-03-21PDF 1.9 MB
Test Report DTS 5GHz 2Test Report2013-03-21PDF 3.3 MB
Test Report DTS 5GHz 3Test Report2013-03-21PDF 5.7 MB
Authorization LetterCover Letter(s)2013-03-21PDF 42.4 KB
Confidentiality LetterCover Letter(s)2013-03-21PDF 39.7 KB
RF Exposure Info MPERF Exposure Info2013-03-21PDF 167.6 KB

Application Information

Application IDyDNHoR/y014hNXKUFINGLw==
Final Action Date2013-03-21
Application PurposeOriginal Equipment
Applicant FRN0015152226
Model-WA8011N
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionA8-Ein Super WiFi Base Station
Responsible PartyLawrence Leung, Product Engineering Manager, khleung@altaitechnologies.com , 852-2116-8087
Technical ContactSunny Lu, Audix Technology, sunny_lu@audix.com.cn , 8675526639497
Test FirmSmart Tsai, Audix Technology (Shenzhen) Co., sindy_song@audix.com.cn , 86-755-663-9495
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is conducted. The antenna(s) used for this transmitter must be fixed point to point professional installation to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. This device is a 2 x 2 MIMO configuration, enabled for 2.4GHz and 5GHz band operation and has 20 MHz and 40 MHz bandwidth modes as described in this filing. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
yDNHoR/y014hNXKUFINGLw==2013-03-21Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.041315C17, MO
2422-2452 MHz0.044215C17, MO
5745-5825 MHz0.03215C17, MO

Grants

TCB Grant - Application yDNHoR/y014hNXKUFINGLw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/21/2013

Application Dated: 03/21/2013
Altai Technologies Limited
Unit 209, 2/F, Lakeside 2,
10 Science Park West Avenue, HK Science Park,
Shatin,
Hong Kong
 
Attention: Lawrence Leung , Product Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  UCC-WA8011N
Name of Grantee:  Altai Technologies Limited
Equipment Class: Digital Transmission System
Notes: A8-Ein Super WiFi Base Station
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
17 MO 15C 2412.0  -  2462.0 0.0413  
17 MO 15C 2422.0  -  2452.0 0.0442  
17 MO 15C 5745.0  -  5825.0 0.032  

Power Output listed is conducted. The antenna(s) used for this transmitter must be fixed point to point professional installation to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. This device is a 2 x 2 MIMO configuration, enabled for 2.4GHz and 5GHz band operation and has 20 MHz and 40 MHz bandwidth modes as described in this filing. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

17: Computing devices into which this device is installed must employ shielded interconnect cables.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application yDNHoR/y014hNXKUFINGLw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Altai Technologies Limited
Unit 209, 2/F, Lakeside 2, 10 Science Park West Avenue, HK Science Park,
Shatin,
Hong Kong
  Date of Grant: 03/21/2013

Application Dated: 03/21/2013
 
Attention: Lawrence Leung , Product Engineering Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  UCC-WA8011N
Name of Grantee:  Altai Technologies Limited
Equipment Class: Digital Transmission System
Notes: A8-Ein Super WiFi Base Station
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
17 MO 15C 2412.0  -  2462.0 0.0413  
17 MO 15C 2422.0  -  2452.0 0.0442  
17 MO 15C 5745.0  -  5825.0 0.032  

Power Output listed is conducted. The antenna(s) used for this transmitter must be fixed point to point professional installation to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. This device is a 2 x 2 MIMO configuration, enabled for 2.4GHz and 5GHz band operation and has 20 MHz and 40 MHz bandwidth modes as described in this filing. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.


17: Computing devices into which this device is installed must employ shielded interconnect cables.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: