FCC ID UDTSP-120
Tri-Mode GSM Phone
by Uriver Inc.
Grantee Code: UDT Product Code: SP120
Latest application date: 2006-07-20
FCC ID Device Details
| FCC ID | UDTSP-120 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | UDT |
| Product Code | SP120 |
| Applicant Business | Uriver Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | Tri-Mode GSM Phone |
| Test Firm | HCT Co., LTD |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2006-07-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2006-07-20 | PDF 1.1 MB |
| Internal Photos | Internal Photos | 2006-07-20 | PDF 1.3 MB |
| External Photos | External Photos | 2006-07-20 | PDF 717.6 KB |
| Label Info | ID Label/Location Info | 2006-07-20 | PDF 343.6 KB |
| Test Setup Photos | Test Setup Photos | 2006-07-20 | PDF 522 KB |
| Annex to Test Report | Test Report | 2006-07-20 | PDF 361 KB |
| Test Report | Test Report | 2006-07-20 | PDF 468.3 KB |
| Attestation Statement | Cover Letter(s) | 2006-07-20 | PDF 132.6 KB |
| Request for Confidentiality | Cover Letter(s) | 2006-07-20 | PDF 126.7 KB |
| SAR Dipole Calibration | RF Exposure Info | 2006-07-20 | PDF 1.5 MB |
| SAR Dipole Validation | RF Exposure Info | 2006-07-20 | PDF 542.7 KB |
| SAR Probe Calibration | RF Exposure Info | 2006-07-20 | PDF 1.1 MB |
| SAR Report | RF Exposure Info | 2006-07-20 | PDF 1.3 MB |
| SAR Report Annex 1 | RF Exposure Info | 2006-07-20 | PDF 1.6 MB |
| SAR Report Annex 2 | RF Exposure Info | 2006-07-20 | PDF 835.5 KB |
| SAR Report Photos | RF Exposure Info | 2006-07-20 | PDF 662.1 KB |
| Block Diagram Metadata only | Block Diagram | PDF 304 KB | |
| Schematics Metadata only | Schematics | PDF 723.7 KB | |
| Operational Description Metadata only | Operational Description | PDF 739.2 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 186.5 KB |
Application Information
| Application ID | 2F8+pP+exk8ZD68zXq+mdw== |
|---|---|
| Final Action Date | 2006-07-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017849282 |
| Model | SP-120 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | Tri-Mode GSM Phone |
| Responsible Party | SK Choi, CTO, skchoi@uriver.co.kr |
| Agent | Ki-Soo Ki-Soo Ki-Soo, HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES C, kisookim@hct.co.kr |
| Technical Contact | Ki-Soo Kim, HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES C, kisookim@hct.co.kr |
| Non-Technical Contact | Ki-Soo Kim, HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES C, kisookim@hct.co.kr |
| Test Firm | Sang Lee, HCT Co., LTD, sjlee@HCT.co.kr |
| TCB Email | selck.bernd@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. This device contains 1800 MHz GSM functions that are not operational in U.S. Territories. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.935 W/kg, Body: 0.272 W/kg; Part 22 - Head: 0.640 W/kg, Body: 0.307 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 2F8+pP+exk8ZD68zXq+mdw== | 2006-07-20 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application 2F8+pP+exk8ZD68zXq+mdw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 07/20/2006 Application Dated: 07/20/2006 |
| Uriver Inc. |
| 3/F., Bogwang Bldg, Gaepo-dong, 1238-7 |
| Gangnam-gu, |
| Seoul, 135-964 South Korea |
| Attention: SK Choi , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | UDTSP-120 |
| Name of Grantee: | Uriver Inc. |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Tri-Mode GSM Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.303 | 2.5 PM | 300KGXW | |
| 22H | 824.2 - 848.8 | 0.367 | 2.5 PM | 300KGXW |
| Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. This device contains 1800 MHz GSM functions that are not operational in U.S. Territories. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.935 W/kg, Body: 0.272 W/kg; Part 22 - Head: 0.640 W/kg, Body: 0.307 W/kg. |
EAS Grant - Application 2F8+pP+exk8ZD68zXq+mdw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Uriver Inc. 3/F., Bogwang Bldg, Gaepo-dong, 1238-7 Gangnam-gu, Seoul, 135-964 South Korea |
Date of Grant: 07/20/2006 Application Dated: 07/20/2006 |
| Attention: SK Choi , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | UDTSP-120 |
| Name of Grantee: | Uriver Inc. |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Tri-Mode GSM Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.2 - 1909.8 | 0.303 | 2.5 PM | 300KGXW | |
| 22H | 824.2 - 848.8 | 0.367 | 2.5 PM | 300KGXW |
| Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. This device contains 1800 MHz GSM functions that are not operational in U.S. Territories. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0.935 W/kg, Body: 0.272 W/kg; Part 22 - Head: 0.640 W/kg, Body: 0.307 W/kg. |