FCC ID UDV-SIM900E

GSM/GPRS module

by Shanghai Simcom Ltd.

Grantee Code: UDV   Product Code: SIM900E
Latest application date: 2013-07-07

FCC ID Device Details

FCC IDUDV-SIM900E
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeUDV
Product CodeSIM900E
Applicant BusinessShanghai Simcom Ltd. 🇨🇳
Related Domains sim.com
Equipment ClassGSM/GPRS module
Test FirmTA Technology (Shanghai) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2013-07-07

Exhibits

DocumentTypeAvailableFile
SIM900E_User Manual_Rev2Users Manual2013-07-07PDF 448.6 KB
SIM900E_Internal Photos.pdfInternal Photos2013-07-07PDF 68.4 KB
SIM900E_Accessories Photos_Rev1.pdfExternal Photos2013-07-07PDF 301.7 KB
SIM900E_External Photos.pdfExternal Photos2013-07-07PDF 211.4 KB
SIM900E_Lable & Location.pdfID Label/Location Info2013-07-07PDF 87.5 KB
SIMC900E_RXA1305-0050RF01_Part22_Test Setup Photo.pdfTest Setup Photos2013-07-07PDF 113.7 KB
SIMC900E_RXA1305-0050RF02_Part24_Test Setup Photo.pdfTest Setup Photos2013-07-07PDF 85.4 KB
SIM900E_RXA1305-0050RF01R2_Part22.pdfTest Report2013-07-07PDF 629.5 KB
SIM900E_RXA1305-0050RF02R2_Part24.pdfTest Report2013-07-07PDF 611.7 KB
SIM900E_FCC Confidentiality Letter.pdfCover Letter(s)2013-07-07PDF 455.4 KB
SIM900E_Moular Letter.pdfCover Letter(s)2013-07-07PDF 50.8 KB
SIM900E_authorization Letter.pdfCover Letter(s)2013-07-07PDF 464.9 KB
SIM900E_2013SAR185_MPE_Rev2RF Exposure Info2013-07-07PDF 1.3 MB

Application Information

Application IDP1QWDOWkHUjY+Okq/Kf3Mw==
Final Action Date2013-07-07
Application PurposeOriginal Equipment
Applicant FRN0015216328
Model-SIM900E
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionGSM/GPRS module
Responsible Partyyongsheng Li, Deputy General Manager, yongsheng.li@sim.com , +86 21 32523134
AgentXiang Xiang Xiang, Shanghai Tejet Communications Technology Co., Ltd, xiangmeixiu@tejet.cn , +86-21-61650880
Technical ContactXiang Meixiu, Shanghai Tejet Communications Technology Co., Ltd., xiangmeixiu@tejet.cn , +86-21-61650880
Test FirmZhihui Liu, TA Technology (Shanghai) Co., Ltd., liuzhihui@ta-shanghai.com , 86-21-50791141
TCB Emailhotline@acbcert.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsSingle Modular Approval. Power out is conducted at the antenna terminal. ERP for part 22 is 32.87 dBm and EIRP for part 24 is 27.23 dBm. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install the SIM900E module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed 2.5 dBi at 1900 MHz and 4.5 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. Under no condition may an antenna gain be used that would exceed the 7W erp Part 22 and the 2W eirp Part 24 power limits. The Grantee is responsible for providing the documentation required for modular use.

Applications

Application IDDatePurpose
P1QWDOWkHUjY+Okq/Kf3Mw==2013-07-07Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.840.1ppm300KGXW22H
1850.2-1909.8 MHz0.9120.1ppm300KGXW24E

Grants

TCB Grant - Application P1QWDOWkHUjY+Okq/Kf3Mw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/07/2013

Application Dated: 07/04/2013
Shanghai Simcom Ltd.
SIM Technology Building,No.633, Jinzhong Road,
Changning District, Shanghai, P.R. ChinaP.O. Box 200233,
Shanghai,
China
 
Attention: yongsheng Li , Deputy General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  UDV-SIM900E
Name of Grantee:  Shanghai Simcom Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: GSM/GPRS module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.84 0.1  PM 300KGXW
24E 1850.2  -  1909.8 0.912 0.1  PM 300KGXW

Single Modular Approval. Power out is conducted at the antenna terminal. ERP for part 22 is 32.87 dBm and EIRP for part 24 is 27.23 dBm. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install the SIM900E module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed 2.5 dBi at 1900 MHz and 4.5 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. Under no condition may an antenna gain be used that would exceed the 7W erp Part 22 and the 2W eirp Part 24 power limits. The Grantee is responsible for providing the documentation required for modular use.

EAS Grant - Application P1QWDOWkHUjY+Okq/Kf3Mw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shanghai Simcom Ltd.
SIM Technology Building,No.633, Jinzhong Road, Changning District, Shanghai, P.R. ChinaP.O. Box 200233,
Shanghai,
China
  Date of Grant: 07/07/2013

Application Dated: 07/04/2013
 
Attention: yongsheng Li , Deputy General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  UDV-SIM900E
Name of Grantee:  Shanghai Simcom Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: GSM/GPRS module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.84 0.1  PM 300KGXW
24E 1850.2  -  1909.8 0.912 0.1  PM 300KGXW

Single Modular Approval. Power out is conducted at the antenna terminal. ERP for part 22 is 32.87 dBm and EIRP for part 24 is 27.23 dBm. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install the SIM900E module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed 2.5 dBi at 1900 MHz and 4.5 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. Under no condition may an antenna gain be used that would exceed the 7W erp Part 22 and the 2W eirp Part 24 power limits. The Grantee is responsible for providing the documentation required for modular use.



Mail To: