FCC ID V5PA6630

Smart Payment Termina

by PAX Technology Limited

Grantee Code: V5P   Product Code: A6630
Latest application date: 2024-12-23

FCC ID Device Details

FCC IDV5PA6630
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeV5P
Product CodeA6630
Applicant BusinessPAX Technology Limited 🇨🇳
Related Domains paxsz.com
Equipment ClassSmart Payment Termina
Test FirmShenzhen UnionTrust Quality and Technology Co., Lt

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
729-746 MHzOriginal Equipment2024-12-23
13.56 MHzOriginal Equipment2024-12-23
5180-5240 MHzOriginal Equipment2024-12-23
2402-2480 MHzOriginal Equipment2024-12-23
704-711 MHzOriginal Equipment2024-12-23
2412-2462 MHzOriginal Equipment2024-12-23

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2025-06-21PDF 280.1 KB
UserManualUsers Manual2025-06-21PDF 280.1 KB
Internal PhotosInternal Photos2025-06-21PDF 4.6 MB
internal photosInternal Photos2025-06-21PDF 4.6 MB
External PhotosExternal Photos2025-06-21PDF 2.1 MB
External photosExternal Photos2025-06-21PDF 2.1 MB
LabelID Label/Location Info2024-12-23PDF 398.1 KB
Label LocationID Label/Location Info2024-12-23PDF 398.1 KB
labelID Label/Location Info2024-12-23PDF 398.1 KB
APPENDIX 1 TEST SETUPTest Setup Photos2025-06-21PDF 1.5 MB
APPENDIX 1 TEST SETUPTest Setup Photos2025-06-21PDF 1.2 MB
Appendix D PhotographsTest Setup Photos2025-06-21PDF 812 KB
Appendix D Test Setup PhotosTest Setup Photos2025-06-21PDF 812 KB
SAR test setup photosTest Setup Photos2025-06-21PDF 812 KB
Test Setup PhotosTest Setup Photos2025-06-21PDF 939.2 KB
test setup photosTest Setup Photos2025-06-21PDF 1.2 MB
test setup photosTest Setup Photos2025-06-21PDF 665.4 KB
test setup photosTest Setup Photos2025-06-21PDF 1.1 MB
Antenna SpecificationTest Report2024-12-23PDF 2.8 MB
Antenna reportTest Report2024-12-23PDF 2.8 MB
Antenna specificationTest Report2024-12-23PDF 2.8 MB
FCC Part 22H&24E&27 Report 3G_1Test Report2024-12-23PDF 5.5 MB
FCC Part 22H&24E&27 Report 3G_2Test Report2024-12-23PDF 4.4 MB
FCC Part 22H&24E&27 Report 3G_3Test Report2024-12-23PDF 2.5 MB
LTE Test Report Part 1Test Report2024-12-23PDF 5.4 MB
LTE Test Report Part 10Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 11Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 12Test Report2024-12-23PDF 4 MB
LTE Test Report Part 13Test Report2024-12-23PDF 4.7 MB
LTE Test Report Part 14Test Report2024-12-23PDF 4.6 MB
LTE Test Report Part 15Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 16Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 17Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 18Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 19Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 2Test Report2024-12-23PDF 4 MB
LTE Test Report Part 20Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 21Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 22Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 23Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 24Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 25Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 26Test Report2024-12-23PDF 5.2 MB
LTE Test Report Part 27Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 28Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 29Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 3Test Report2024-12-23PDF 3.9 MB
LTE Test Report Part 30Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 31Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 32Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 33Test Report2024-12-23PDF 2.2 MB
LTE Test Report Part 4Test Report2024-12-23PDF 3.9 MB
LTE Test Report Part 5Test Report2024-12-23PDF 3.9 MB
LTE Test Report Part 6Test Report2024-12-23PDF 4.4 MB
LTE Test Report Part 7Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 8Test Report2024-12-23PDF 5.1 MB
LTE Test Report Part 9Test Report2024-12-23PDF 4.3 MB
Part 15.247 BLE ReportTest Report2024-12-23PDF 2.9 MB
Part 15.247 Report PART1Test Report2024-12-23PDF 5.5 MB
Part 15.247 Report PART2Test Report2024-12-23PDF 2.8 MB
Part 15.407 Report part1Test Report2024-12-23PDF 5.4 MB
Part 15.407 Report part2Test Report2024-12-23PDF 2.7 MB
Part 15.407 Report part3Test Report2024-12-23PDF 4.4 MB
Part 15.407 Report part4Test Report2024-12-23PDF 4.4 MB
Part 15.407 Report part5Test Report2024-12-23PDF 941.4 KB
SAR Test ReportRF Exposure Info2024-12-23PDF 3 MB
SAR test reportRF Exposure Info2024-12-23PDF 3 MB
SAR test report appendix ARF Exposure Info2024-12-23PDF 2.5 MB
SAR test report appendix BRF Exposure Info2024-12-23PDF 3.4 MB
SAR test report appendix C_1RF Exposure Info2024-12-23PDF 4.3 MB
SAR test report appendix C_2RF Exposure Info2024-12-23PDF 2.5 MB
test reportTest Report2024-12-23PDF 2.7 MB
test reportTest Report2024-12-23PDF 1.3 MB
test report_1Test Report2024-12-23PDF 5.5 MB
test report_2Test Report2024-12-23PDF 2.3 MB
Attestation Section 2.911(d)(5)(i)&(ii)Attestation Statements2024-12-23PDF 573.3 KB
Attestation Statements US agent for service of processAttestation Statements2024-12-23PDF 570.9 KB
Attestation Statements 2.911 d 5Attestation Statements2024-12-23PDF 573.3 KB
Attestation Statements Part 2.911 i iiAttestation Statements2024-12-23PDF 573.3 KB
US AGENT LetterAttestation Statements2024-12-23PDF 570.9 KB
US Agent letterAttestation Statements2024-12-23PDF 570.9 KB
Authority LetterCover Letter(s)2024-12-23PDF 138.5 KB
Confidentiality LetterCover Letter(s)2024-12-23PDF 192.6 KB
POACover Letter(s)2024-12-23PDF 138.5 KB
POA letterCover Letter(s)2024-12-23PDF 138.5 KB
confidentiality letterCover Letter(s)2024-12-23PDF 192.6 KB
Appendix 5G WIFI 121-180RF Exposure Info2024-12-23PDF 3.4 MB
Appendix A SAR Plots of System VerificationRF Exposure Info2024-12-23PDF 2.5 MB
Appendix B SAR Plots of SAR MeasurementRF Exposure Info2024-12-23PDF 3.4 MB
Appendix B SAR_MeasurementRF Exposure Info2024-12-23PDF 3.4 MB
Appendix C Calibration Certificate for Probe and Dipole Part 1RF Exposure Info2024-12-23PDF 4.3 MB
Appendix C Calibration Certificate for Probe and Dipole Part 2RF Exposure Info2024-12-23PDF 2.5 MB
Appendix C SAR_Calibration Certificate Part 1RF Exposure Info2024-12-23PDF 4.3 MB
Appendix C SAR_Calibration Certificate Part 2RF Exposure Info2024-12-23PDF 2.5 MB
RF exposure reportRF Exposure Info2024-12-23PDF 288.7 KB
SAR ReportRF Exposure Info2024-12-23PDF 3 MB
Blcok Diagram Metadata onlyBlock DiagramPDF 94.6 KB
Block Diagram Metadata onlyBlock DiagramPDF 94.6 KB
Main PCB Layer Metadata onlySchematicsPDF 1.6 MB
Main Schematic Diagram Metadata onlySchematicsPDF 569 KB
PCB Layer Metadata onlySchematicsPDF 366.2 KB
PCB layout_mainboard Metadata onlySchematicsPDF 1.6 MB
PCB layout_port Metadata onlySchematicsPDF 366.2 KB
Schematic Diagram Metadata onlySchematicsPDF 62.7 KB
Schematics_mainboard Metadata onlySchematicsPDF 569 KB
Schematics_port Metadata onlySchematicsPDF 62.7 KB
V02 PCB Metadata onlySchematicsPDF 366.2 KB
V02 SCH Metadata onlySchematicsPDF 62.7 KB
V03 PCB Metadata onlySchematicsPDF 1.6 MB
V03 SCH Metadata onlySchematicsPDF 569 KB
Operation Description Metadata onlyOperational DescriptionPDF 164.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 164.5 KB
SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata onlySDR Software/Security Info.PDF 322.9 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 259.4 KB
BOM_mainboard Metadata onlyParts List/Tune Up InfoPDF 248.6 KB
Bom Metadata onlyParts List/Tune Up InfoPDF 259.4 KB
Main Parts List Metadata onlyParts List/Tune Up InfoPDF 248.6 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 259.4 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 200.3 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 200.3 KB
V02 BOM Metadata onlyParts List/Tune Up InfoPDF 248.6 KB
V03 BOM Metadata onlyParts List/Tune Up InfoPDF 248.6 KB
tune-up procedure Metadata onlyParts List/Tune Up InfoPDF 200.3 KB

Application Information

Application IDvwGQjoRqYp20MPUsZl6rnQ==
Final Action Date2024-12-23
Application PurposeOriginal Equipment
Applicant FRN0017536285
ModelA6630
Frequency Range729-746 MHz
Equipment ClassCXX - Communications Rcvr for use w/ licensed Tx and CBs
Device DescriptionSmart Payment Termina
Responsible PartyJenna Tan, certservice@paxsz.com , 86-755-86156663
Test FirmGeorge Luo, Shenzhen UnionTrust Quality and Technology Co., Lt, quality@uttlab.com , +86-755-28230888
TCB EmailTEI@timcoengr.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityYes
Short-Term Confidentiality Date06/21/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
vwGQjoRqYp20MPUsZl6rnQ==2024-12-23Original Equipment
rZs/vzVtzdlD3FNce/LxFg==2024-12-23Original Equipment
mFGYXp5hsNHl4YxRw2ESuA==2024-12-23Original Equipment
TSPN2jecDnxJj4fm3oczzA==2024-12-23Original Equipment
FsO6HfxlpJWm7osgYx6JZA==2024-12-23Original Equipment
EUfC6EkcXtBDu8BbHHrnyQ==2024-12-23Original Equipment
BK56TwEgQQzl5RCAyoa5MQ==2024-12-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
13.56 MHz15CCC
704-711 MHz0.008720.2131ppm9M08G7D27
704-711 MHz0.006617.0745ppm9M05W7D27
709-711 MHz0.007912.555ppm9M05G7D27
709-711 MHz0.006118.3498ppm9M04W7D27
729-746 MHz15BCC
734-746 MHz15BCC
746-756 MHz15BCC
782 MHz0.05312.5831ppm8M98G7D27
782 MHz0.042710.4554ppm8M98W7D27
826.4-846.6 MHz0.06470.0157ppm4M17F9W22H
829-844 MHz0.09230.0264ppm8M99G7D22H
829-844 MHz0.0710.0261ppm8M98W7D22H
869-894 MHz15BCC
1712.4-1752.6 MHz0.11973.6917ppm4M16F9W27
1720-1745 MHz0.099320.4241ppm18M0G7D27
1720-1745 MHz0.079314.2947ppm18M0W7D27
1860-1900 MHz0.11813.2688ppm18M0G7D24E
1860-1900 MHz0.08917.144ppm18M0W7D24E
2402-2480 MHz0.011700015CCC
2402-2480 MHz0.0005915CCC
2412-2462 MHz0.2213115CCC
5180-5240 MHz0.0157415ECC
5260-5320 MHz0.0152115ECC
5500-5720 MHz0.0217315ECC
5745-5825 MHz0.0213815ECC

Grants

TCB Grant - Application vwGQjoRqYp20MPUsZl6rnQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Communications Rcvr for use w/ licensed Tx and CBs
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B 869.0  -  894.0
CC 15B 729.0  -  746.0
CC 15B 746.0  -  756.0
CC 15B 734.0  -  746.0


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application vwGQjoRqYp20MPUsZl6rnQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Communications Rcvr for use w/ licensed Tx and CBs
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B 869.0  -  894.0
CC 15B 729.0  -  746.0
CC 15B 746.0  -  756.0
CC 15B 734.0  -  746.0


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application TSPN2jecDnxJj4fm3oczzA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application TSPN2jecDnxJj4fm3oczzA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application rZs/vzVtzdlD3FNce/LxFg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application rZs/vzVtzdlD3FNce/LxFg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application mFGYXp5hsNHl4YxRw2ESuA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01574  
CC 15E 5260.0  -  5320.0 0.01521  
CC 15E 5500.0  -  5720.0 0.02173  
CC 15E 5745.0  -  5825.0 0.02138  

Output Power listed is the maximum conducted output power. The highest reported SAR 1.17 W/kg, respectively. This device supports 20, 40 and 80 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application mFGYXp5hsNHl4YxRw2ESuA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.01574  
CC 15E 5260.0  -  5320.0 0.01521  
CC 15E 5500.0  -  5720.0 0.02173  
CC 15E 5745.0  -  5825.0 0.02138  

Output Power listed is the maximum conducted output power. The highest reported SAR 1.17 W/kg, respectively. This device supports 20, 40 and 80 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application FsO6HfxlpJWm7osgYx6JZA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0117  

Output Power listed is conducted.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application FsO6HfxlpJWm7osgYx6JZA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0117  

Output Power listed is conducted.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application EUfC6EkcXtBDu8BbHHrnyQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: PCS Licensed Transmitter
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1852.4  -  1907.6 0.1355 10.71  PM 4M17F9W
27 1712.4  -  1752.6 0.1197 3.6917  PM 4M16F9W
22H 826.4  -  846.6 0.0647 0.0157  PM 4M17F9W
24E 1860.0  -  1900.0 0.118 13.2688  PM 18M0G7D
24E 1860.0  -  1900.0 0.0891 7.144  PM 18M0W7D
27 1720.0  -  1745.0 0.0993 20.4241  PM 18M0G7D
27 1720.0  -  1745.0 0.0793 14.2947  PM 18M0W7D
22H 829.0  -  844.0 0.0923 0.0264  PM 8M99G7D
22H 829.0  -  844.0 0.071 0.0261  PM 8M98W7D
27 704.0  -  711.0 0.0087 20.2131  PM 9M08G7D
27 704.0  -  711.0 0.0066 17.0745  PM 9M05W7D
27 782.0  -  782.0 0.053 12.5831  PM 8M98G7D
27 782.0  -  782.0 0.0427 10.4554  PM 8M98W7D
27 709.0  -  711.0 0.0079 12.555  PM 9M05G7D
27 709.0  -  711.0 0.0061 18.3498  PM 9M04W7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. The highest reported SAR is 0.98 W/kg. This device supports LTE of 1.4, 3, 5, 10, 15 and 20 MHz bandwidth modes for FDD LTE Bands 2 and 4; LTE of 1.4, 3, 5 and 10 MHz bandwidth modes for FDD LTE Bands 5 and 12; and LTE of 5 and 10 MHz bandwidth modes for FDD LTE Bands 13 and 17.

EAS Grant - Application EUfC6EkcXtBDu8BbHHrnyQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: PCS Licensed Transmitter
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1852.4  -  1907.6 0.1355 10.71  PM 4M17F9W
27 1712.4  -  1752.6 0.1197 3.6917  PM 4M16F9W
22H 826.4  -  846.6 0.0647 0.0157  PM 4M17F9W
24E 1860.0  -  1900.0 0.118 13.2688  PM 18M0G7D
24E 1860.0  -  1900.0 0.0891 7.144  PM 18M0W7D
27 1720.0  -  1745.0 0.0993 20.4241  PM 18M0G7D
27 1720.0  -  1745.0 0.0793 14.2947  PM 18M0W7D
22H 829.0  -  844.0 0.0923 0.0264  PM 8M99G7D
22H 829.0  -  844.0 0.071 0.0261  PM 8M98W7D
27 704.0  -  711.0 0.0087 20.2131  PM 9M08G7D
27 704.0  -  711.0 0.0066 17.0745  PM 9M05W7D
27 782.0  -  782.0 0.053 12.5831  PM 8M98G7D
27 782.0  -  782.0 0.0427 10.4554  PM 8M98W7D
27 709.0  -  711.0 0.0079 12.555  PM 9M05G7D
27 709.0  -  711.0 0.0061 18.3498  PM 9M04W7D

Output Power is EIRP and ERP for above and below 1 GHz, respectively. The highest reported SAR is 0.98 W/kg. This device supports LTE of 1.4, 3, 5, 10, 15 and 20 MHz bandwidth modes for FDD LTE Bands 2 and 4; LTE of 1.4, 3, 5 and 10 MHz bandwidth modes for FDD LTE Bands 5 and 12; and LTE of 5 and 10 MHz bandwidth modes for FDD LTE Bands 13 and 17.



TCB Grant - Application BK56TwEgQQzl5RCAyoa5MQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 12/23/2024

Application Dated: 12/23/2024
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Digital Transmission System
Notes: Smart Payment Termina
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00059  
CC 15C 2412.0  -  2462.0 0.22131  

Output Power listed is the maximum conducted output power. The highest reported SAR 0.77 W/kg, respectively. This device supports 20 and 40 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application BK56TwEgQQzl5RCAyoa5MQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 12/23/2024

Application Dated: 12/23/2024
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PA6630
Name of Grantee:  PAX Technology Limited
Equipment Class: Digital Transmission System
Notes: Smart Payment Termina
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.00059  
CC 15C 2412.0  -  2462.0 0.22131  

Output Power listed is the maximum conducted output power. The highest reported SAR 0.77 W/kg, respectively. This device supports 20 and 40 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: