FCC ID V5PM50

Mobile Payment Cell Phone

by PAX Technology Limited

Grantee Code: V5P   Product Code: M50
Latest application date: 2021-11-02

FCC ID Device Details

FCC IDV5PM50
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeV5P
Product CodeM50
Applicant BusinessPAX Technology Limited 🇨🇳
Related Domains paxsz.com
Equipment ClassMobile Payment Cell Phone
Test FirmSGS-CSTC Standards Technical Services Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzClass II permissive change or modification of presently authorized equipment2021-11-02
700.5-714.5 MHzClass II permissive change or modification of presently authorized equipment2021-11-02
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2021-11-01
2402-2480 MHzClass II permissive change or modification of presently authorized equipment2021-11-01
13.56 MHzClass II permissive change or modification of presently authorized equipment2021-11-01
700.5-714.5 MHzOriginal Equipment2021-02-04
13.56 MHzOriginal Equipment2021-02-03
5180-5240 MHzOriginal Equipment2021-02-03
2402-2480 MHzOriginal Equipment2021-02-03
2402-2480 MHzOriginal Equipment2021-02-03

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2021-08-03PDF 390.6 KB
User ManualUsers Manual2021-08-03PDF 390.6 KB
Internal PhotosInternal Photos2021-11-02PDF 1.7 MB
Internal PhotoInternal Photos2021-08-03PDF 2.3 MB
Internal PhotosInternal Photos2021-08-03PDF 2.3 MB
External PhotosExternal Photos2021-11-02PDF 867.3 KB
External PhotoExternal Photos2021-08-03PDF 543.6 KB
External PhotosExternal Photos2021-08-03PDF 543.6 KB
E-LABELID Label/Location Info2021-02-04PDF 40.9 KB
E-LabelID Label/Location Info2021-02-04PDF 166.4 KB
E-LABELID Label/Location Info2021-02-03PDF 166.4 KB
e-labelID Label/Location Info2021-02-03PDF 40.9 KB
Test Setup PhotosTest Setup Photos2021-11-02PDF 251.3 KB
Test setup photoTest Setup Photos2021-11-02PDF 319.7 KB
test setup photoTest Setup Photos2021-11-02PDF 319.7 KB
Test Setup PhotosTest Setup Photos2021-11-01PDF 230.5 KB
Test Setup PhotosTest Setup Photos2021-11-01PDF 326.9 KB
Test Setup PhotoTest Setup Photos2021-08-03PDF 599.3 KB
Test Setup PhotoTest Setup Photos2021-08-03PDF 500.7 KB
Test Setup PhotoTest Setup Photos2021-08-03PDF 415 KB
Test Setup PhotosTest Setup Photos2021-08-03PDF 379.2 KB
Test Setup photoTest Setup Photos2021-08-03PDF 500.7 KB
Test setup photoTest Setup Photos2021-08-03PDF 500.7 KB
SAR Test ReportRF Exposure Info2021-11-02PDF 4.1 MB
SAR Test reportRF Exposure Info2021-11-02PDF 5.3 MB
Test ReportTest Report2021-11-02PDF 5.3 MB
Test reportTest Report2021-11-02PDF 1.5 MB
Test reportTest Report2021-11-02PDF 5 MB
Test ReportTest Report2021-11-01PDF 1,012.5 KB
Test reportTest Report2021-11-01PDF 1.7 MB
Test reportTest Report2021-11-01PDF 3.4 MB
SAR Test ReportRF Exposure Info2021-02-04PDF 5.8 MB
Test ReportTest Report2021-02-04PDF 5.9 MB
SAR Test ReportTest Report2021-02-03PDF 3.9 MB
SAR Test ReportTest Report2021-02-03PDF 5.8 MB
SAR Test ReportRF Exposure Info2021-02-03PDF 3.9 MB
Test ReportTest Report2021-02-03PDF 5.6 MB
Test ReportTest Report2021-02-03PDF 4.8 MB
Test ReportTest Report2021-02-03PDF 4.4 MB
Test ReportTest Report2021-02-03PDF 5.3 MB
Applicant_Declaration_LetterCover Letter(s)2021-11-02PDF 789.5 KB
C2PC COVER LETTERCover Letter(s)2021-11-02PDF 457.1 KB
C2PC Cover letterCover Letter(s)2021-11-02PDF 457.1 KB
FCC Declaration LetterCover Letter(s)2021-11-02PDF 789.5 KB
POACover Letter(s)2021-11-02PDF 480.6 KB
APPLICANT COVER LETTERCover Letter(s)2021-11-01PDF 789.5 KB
C2PC Cover LetterCover Letter(s)2021-11-01PDF 457.1 KB
Applicant_Declaration_LetterCover Letter(s)2021-02-04PDF 354.9 KB
Confidentiality LetterCover Letter(s)2021-02-04PDF 620.7 KB
POACover Letter(s)2021-02-04PDF 401.6 KB
Channel StatementCover Letter(s)2021-02-03PDF 407.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 133.7 KB
SCH Metadata onlySchematicsPDF 1.1 MB
Schematic Metadata onlySchematicsPDF 1.1 MB
Schematic Metadata onlySchematicsPDF 235.2 KB
Operation Description Metadata onlyOperational DescriptionPDF 84.8 KB
Operational Description Metadata onlyOperational DescriptionPDF 84.8 KB
SDR Software Metadata onlySDR Software/Security InfPDF 34.6 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 220.7 KB
BOM List Metadata onlyParts List/Tune Up InfoPDF 220.7 KB
BOM List Metadata onlyParts List/Tune Up InfoPDF 122.3 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 157.7 KB

Application Information

Application IDyeAnKJpDtteJmbyPCIj6TA==
Final Action Date2021-11-02
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0017536285
ModelM50
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionMobile Payment Cell Phone
Responsible PartyJenna Tan, certservice@paxsz.com , 86-755-86156663
Technical ContactKobe Jian, SGS-CSTC Standards Technical Services Co., Ltd., kobe.Jian@sgs.com , +862082155314
Test FirmKobe Jian, SGS-CSTC Standards Technical Services Co., Ltd., kobe.jian@sgs.com , 86-0-20-82155314
TCB EmailUSCTS.TCB@SGS.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.64 W/Kg, Body 0.68 W/Kg and simultaneous transmission 0.97 W/Kg, respectively. This device supports 20MHz, 40MHz and 80MHz bandwidth modes.

Applications

Application IDDatePurpose
yeAnKJpDtteJmbyPCIj6TA==2021-11-02Class II permissive change or modification of presently authorized equipment
oAZruqIhBPTA2sA+Gwl5sA==2021-11-02Class II permissive change or modification of presently authorized equipment
mzzxNAJRHyw+wp701nlAQg==2021-11-01Class II permissive change or modification of presently authorized equipment
KFIpBqurk58qV9Aka16V7Q==2021-11-01Class II permissive change or modification of presently authorized equipment
GGrQpKnnsgf3tTGiZsWwYA==2021-11-01Class II permissive change or modification of presently authorized equipment
uBOu9NFUKKevIwweSMQs1w==2021-02-04Original Equipment
vT15KvjvwApJzrOJ2G+nHg==2021-02-03Original Equipment
kOnuWjBD6Y+wVCb2psQCsA==2021-02-03Original Equipment
enOu6v3b8VUiSTYRYbtl3A==2021-02-03Original Equipment
HKiE+1liAFa8P4XTMxPMeA==2021-02-03Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
13.56 MHz15CCC
700.5-714.5 MHz0.10452.5ppm3M01W7D27
704-711 MHz0.11892.5ppm9M08G7D27
704-711 MHz0.1042.5ppm9M91W7D27
709-711 MHz0.11862.5ppm9M06G7D27
709-711 MHz0.10542.5ppm9M07W7D27
779.5-784.5 MHz0.09042.5ppm4M58W7D27
782 MHz0.11272.5ppm8M97G7D27
782 MHz0.08892.5ppm9M00W7D27
825.5-847.5 MHz0.12252.5ppm2M73G7D22H
829-844 MHz0.12082.5ppm9M08G7D22H
829-844 MHz0.10672.5ppm9M05W7D22H
1711.5-1753.5 MHz0.16792.5ppm2M72W7D27
1711.5-1753.5 MHz0.18842.5ppm2M73G7D27
1720-1745 MHz0.16182.5ppm18M2W7D27
1720-1745 MHz0.18662.5ppm18M2G7D27
1851.5-1908.5 MHz0.16982.5ppm2M72W7D24E
1852.4-1907.6 MHz0.13872.5ppm4M31F9W24E
1855-1905 MHz0.16982.5ppm9M91W7D24E
1860-1900 MHz0.18752.5ppm18M1G7D24E
1860-1900 MHz0.1692.5ppm18M2W7D24E
2402-2480 MHz0.008700015CCC
2402-2480 MHz0.000515CCC
2412-2462 MHz0.03715CCC
2422-2452 MHz0.021115CCC
5190-5230 MHz0.013815ECC
5210 MHz0.013115ECC
5260-5320 MHz0.027415ECC
5270-5310 MHz0.014915ECC
5290 MHz0.013915ECC
5500-5700 MHz0.024315ECC
5510-5670 MHz0.014615ECC
5530-5610 MHz0.012115ECC
5745-5825 MHz0.025915ECC
5755-5795 MHz0.016915ECC
5775 MHz0.013515ECC

Grants

TCB Grant - Application yeAnKJpDtteJmbyPCIj6TA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 11/02/2021

Application Dated: 11/01/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0271  
CC 15E 5190.0  -  5230.0 0.0138  
CC 15E 5210.0  -  5210.0 0.0131  
CC 15E 5260.0  -  5320.0 0.0274  
CC 15E 5270.0  -  5310.0 0.0149  
CC 15E 5290.0  -  5290.0 0.0139  
CC 15E 5500.0  -  5700.0 0.0243  
CC 15E 5510.0  -  5670.0 0.0146  
CC 15E 5530.0  -  5610.0 0.0121  
CC 15E 5745.0  -  5825.0 0.0259  
CC 15E 5755.0  -  5795.0 0.0169  
CC 15E 5775.0  -  5775.0 0.0135  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.64 W/Kg, Body 0.68 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device supports 20MHz, 40MHz and 80MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application yeAnKJpDtteJmbyPCIj6TA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 11/02/2021

Application Dated: 11/01/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0271  
CC 15E 5190.0  -  5230.0 0.0138  
CC 15E 5210.0  -  5210.0 0.0131  
CC 15E 5260.0  -  5320.0 0.0274  
CC 15E 5270.0  -  5310.0 0.0149  
CC 15E 5290.0  -  5290.0 0.0139  
CC 15E 5500.0  -  5700.0 0.0243  
CC 15E 5510.0  -  5670.0 0.0146  
CC 15E 5530.0  -  5610.0 0.0121  
CC 15E 5745.0  -  5825.0 0.0259  
CC 15E 5755.0  -  5795.0 0.0169  
CC 15E 5775.0  -  5775.0 0.0135  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.64 W/Kg, Body 0.68 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device supports 20MHz, 40MHz and 80MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application vT15KvjvwApJzrOJ2G+nHg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 02/03/2021

Application Dated: 02/03/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application vT15KvjvwApJzrOJ2G+nHg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 02/03/2021

Application Dated: 02/03/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application uBOu9NFUKKevIwweSMQs1w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 02/04/2021

Application Dated: 02/03/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.2094 2.5  PM 4M33F9W
27 1712.4  -  1752.6 0.2032 2.5  PM 4M35F9W
24E 1852.4  -  1907.6 0.1387 2.5  PM 4M31F9W
24E 1860.0  -  1900.0 0.1875 2.5  PM 18M1G7D
24E 1851.5  -  1908.5 0.1698 2.5  PM 2M72W7D
24E 1855.0  -  1905.0 0.1698 2.5  PM 9M91W7D
24E 1860.0  -  1900.0 0.169 2.5  PM 18M2W7D
27 1711.5  -  1753.5 0.1884 2.5  PM 2M73G7D
27 1720.0  -  1745.0 0.1866 2.5  PM 18M2G7D
27 1711.5  -  1753.5 0.1679 2.5  PM 2M72W7D
27 1720.0  -  1745.0 0.1618 2.5  PM 18M2W7D
22H 825.5  -  847.5 0.1225 2.5  PM 2M73G7D
22H 829.0  -  844.0 0.1208 2.5  PM 9M08G7D
22H 829.0  -  844.0 0.1067 2.5  PM 9M05W7D
27 704.0  -  711.0 0.1189 2.5  PM 9M08G7D
27 700.5  -  714.5 0.1045 2.5  PM 3M01W7D
27 704.0  -  711.0 0.104 2.5  PM 9M91W7D
27 782.0  -  782.0 0.1127 2.5  PM 8M97G7D
27 779.5  -  784.5 0.0904 2.5  PM 4M58W7D
27 782.0  -  782.0 0.0889 2.5  PM 9M00W7D
27 709.0  -  711.0 0.1186 2.5  PM 9M06G7D
27 709.0  -  711.0 0.1054 2.5  PM 9M07W7D

Output power listed is ERP for WCDMA Band V, LTE Band 5/12/13/17 and EIRP for WCDMA Band II/IV, LTE Band 2/4. This device has 1.4MHz, 3MHz, 5 MHz and 10 MHz bandwidth modes for LTE Band 5/12; 5 MHz and 10 MHz bandwidth modes for LTE Band 13/17; 1.4MHz, 3MHz, 5 MHz, 10MHz, 15MHz and 20MHz bandwidth modes for LTE Band 2/4.

This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.08 W/Kg, Body 0.44 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.


EAS Grant - Application uBOu9NFUKKevIwweSMQs1w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 02/04/2021

Application Dated: 02/03/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.2094 2.5  PM 4M33F9W
27 1712.4  -  1752.6 0.2032 2.5  PM 4M35F9W
24E 1852.4  -  1907.6 0.1387 2.5  PM 4M31F9W
24E 1860.0  -  1900.0 0.1875 2.5  PM 18M1G7D
24E 1851.5  -  1908.5 0.1698 2.5  PM 2M72W7D
24E 1855.0  -  1905.0 0.1698 2.5  PM 9M91W7D
24E 1860.0  -  1900.0 0.169 2.5  PM 18M2W7D
27 1711.5  -  1753.5 0.1884 2.5  PM 2M73G7D
27 1720.0  -  1745.0 0.1866 2.5  PM 18M2G7D
27 1711.5  -  1753.5 0.1679 2.5  PM 2M72W7D
27 1720.0  -  1745.0 0.1618 2.5  PM 18M2W7D
22H 825.5  -  847.5 0.1225 2.5  PM 2M73G7D
22H 829.0  -  844.0 0.1208 2.5  PM 9M08G7D
22H 829.0  -  844.0 0.1067 2.5  PM 9M05W7D
27 704.0  -  711.0 0.1189 2.5  PM 9M08G7D
27 700.5  -  714.5 0.1045 2.5  PM 3M01W7D
27 704.0  -  711.0 0.104 2.5  PM 9M91W7D
27 782.0  -  782.0 0.1127 2.5  PM 8M97G7D
27 779.5  -  784.5 0.0904 2.5  PM 4M58W7D
27 782.0  -  782.0 0.0889 2.5  PM 9M00W7D
27 709.0  -  711.0 0.1186 2.5  PM 9M06G7D
27 709.0  -  711.0 0.1054 2.5  PM 9M07W7D

Output power listed is ERP for WCDMA Band V, LTE Band 5/12/13/17 and EIRP for WCDMA Band II/IV, LTE Band 2/4. This device has 1.4MHz, 3MHz, 5 MHz and 10 MHz bandwidth modes for LTE Band 5/12; 5 MHz and 10 MHz bandwidth modes for LTE Band 13/17; 1.4MHz, 3MHz, 5 MHz, 10MHz, 15MHz and 20MHz bandwidth modes for LTE Band 2/4.

This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.08 W/Kg, Body 0.44 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.



TCB Grant - Application oAZruqIhBPTA2sA+Gwl5sA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 11/02/2021

Application Dated: 11/02/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.2094 2.5  PM 4M33F9W
27 1712.4  -  1752.6 0.2032 2.5  PM 4M35F9W
24E 1852.4  -  1907.6 0.1387 2.5  PM 4M31F9W
24E 1860.0  -  1900.0 0.1875 2.5  PM 18M1G7D
24E 1851.5  -  1908.5 0.1698 2.5  PM 2M72W7D
24E 1855.0  -  1905.0 0.1698 2.5  PM 9M91W7D
24E 1860.0  -  1900.0 0.169 2.5  PM 18M2W7D
27 1711.5  -  1753.5 0.1884 2.5  PM 2M73G7D
27 1720.0  -  1745.0 0.1866 2.5  PM 18M2G7D
27 1711.5  -  1753.5 0.1679 2.5  PM 2M72W7D
27 1720.0  -  1745.0 0.1618 2.5  PM 18M2W7D
22H 825.5  -  847.5 0.1225 2.5  PM 2M73G7D
22H 829.0  -  844.0 0.1208 2.5  PM 9M08G7D
22H 829.0  -  844.0 0.1067 2.5  PM 9M05W7D
27 704.0  -  711.0 0.1189 2.5  PM 9M08G7D
27 700.5  -  714.5 0.1045 2.5  PM 3M01W7D
27 704.0  -  711.0 0.104 2.5  PM 9M91W7D
27 782.0  -  782.0 0.1127 2.5  PM 8M97G7D
27 779.5  -  784.5 0.0904 2.5  PM 4M58W7D
27 782.0  -  782.0 0.0889 2.5  PM 9M00W7D
27 709.0  -  711.0 0.1186 2.5  PM 9M06G7D
27 709.0  -  711.0 0.1054 2.5  PM 9M07W7D

Output power listed is ERP for WCDMA Band V, LTE Band 5/12/13/17 and EIRP for WCDMA Band II/IV, LTE Band 2/4. This device has 1.4MHz, 3MHz, 5 MHz and 10 MHz bandwidth modes for LTE Band 5/12; 5 MHz and 10 MHz bandwidth modes for LTE Band 13/17; 1.4MHz, 3MHz, 5 MHz, 10MHz, 15MHz and 20MHz bandwidth modes for LTE Band 2/4.

This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.08 W/Kg, Body 0.44 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.


EAS Grant - Application oAZruqIhBPTA2sA+Gwl5sA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 11/02/2021

Application Dated: 11/02/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.2094 2.5  PM 4M33F9W
27 1712.4  -  1752.6 0.2032 2.5  PM 4M35F9W
24E 1852.4  -  1907.6 0.1387 2.5  PM 4M31F9W
24E 1860.0  -  1900.0 0.1875 2.5  PM 18M1G7D
24E 1851.5  -  1908.5 0.1698 2.5  PM 2M72W7D
24E 1855.0  -  1905.0 0.1698 2.5  PM 9M91W7D
24E 1860.0  -  1900.0 0.169 2.5  PM 18M2W7D
27 1711.5  -  1753.5 0.1884 2.5  PM 2M73G7D
27 1720.0  -  1745.0 0.1866 2.5  PM 18M2G7D
27 1711.5  -  1753.5 0.1679 2.5  PM 2M72W7D
27 1720.0  -  1745.0 0.1618 2.5  PM 18M2W7D
22H 825.5  -  847.5 0.1225 2.5  PM 2M73G7D
22H 829.0  -  844.0 0.1208 2.5  PM 9M08G7D
22H 829.0  -  844.0 0.1067 2.5  PM 9M05W7D
27 704.0  -  711.0 0.1189 2.5  PM 9M08G7D
27 700.5  -  714.5 0.1045 2.5  PM 3M01W7D
27 704.0  -  711.0 0.104 2.5  PM 9M91W7D
27 782.0  -  782.0 0.1127 2.5  PM 8M97G7D
27 779.5  -  784.5 0.0904 2.5  PM 4M58W7D
27 782.0  -  782.0 0.0889 2.5  PM 9M00W7D
27 709.0  -  711.0 0.1186 2.5  PM 9M06G7D
27 709.0  -  711.0 0.1054 2.5  PM 9M07W7D

Output power listed is ERP for WCDMA Band V, LTE Band 5/12/13/17 and EIRP for WCDMA Band II/IV, LTE Band 2/4. This device has 1.4MHz, 3MHz, 5 MHz and 10 MHz bandwidth modes for LTE Band 5/12; 5 MHz and 10 MHz bandwidth modes for LTE Band 13/17; 1.4MHz, 3MHz, 5 MHz, 10MHz, 15MHz and 20MHz bandwidth modes for LTE Band 2/4.

This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.08 W/Kg, Body 0.44 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.



TCB Grant - Application mzzxNAJRHyw+wp701nlAQg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 11/01/2021

Application Dated: 11/01/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0087  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.11 W/Kg, Body 0.04 W/Kg and simultaneous transmission 0.48 W/Kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application mzzxNAJRHyw+wp701nlAQg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 11/01/2021

Application Dated: 11/01/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0087  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.11 W/Kg, Body 0.04 W/Kg and simultaneous transmission 0.48 W/Kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application kOnuWjBD6Y+wVCb2psQCsA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 02/03/2021

Application Dated: 02/03/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0271  
CC 15E 5190.0  -  5230.0 0.0138  
CC 15E 5210.0  -  5210.0 0.0131  
CC 15E 5260.0  -  5320.0 0.0274  
CC 15E 5270.0  -  5310.0 0.0149  
CC 15E 5290.0  -  5290.0 0.0139  
CC 15E 5500.0  -  5700.0 0.0243  
CC 15E 5510.0  -  5670.0 0.0146  
CC 15E 5530.0  -  5610.0 0.0121  
CC 15E 5745.0  -  5825.0 0.0259  
CC 15E 5755.0  -  5795.0 0.0169  
CC 15E 5775.0  -  5775.0 0.0135  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.64 W/Kg, Body 0.68 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device supports 20MHz, 40MHz and 80MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application kOnuWjBD6Y+wVCb2psQCsA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 02/03/2021

Application Dated: 02/03/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0271  
CC 15E 5190.0  -  5230.0 0.0138  
CC 15E 5210.0  -  5210.0 0.0131  
CC 15E 5260.0  -  5320.0 0.0274  
CC 15E 5270.0  -  5310.0 0.0149  
CC 15E 5290.0  -  5290.0 0.0139  
CC 15E 5500.0  -  5700.0 0.0243  
CC 15E 5510.0  -  5670.0 0.0146  
CC 15E 5530.0  -  5610.0 0.0121  
CC 15E 5745.0  -  5825.0 0.0259  
CC 15E 5755.0  -  5795.0 0.0169  
CC 15E 5775.0  -  5775.0 0.0135  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.64 W/Kg, Body 0.68 W/Kg and simultaneous transmission 0.97 W/Kg, respectively.

This device supports 20MHz, 40MHz and 80MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application KFIpBqurk58qV9Aka16V7Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 11/01/2021

Application Dated: 11/01/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Digital Transmission System
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0005  
CC 15C 2412.0  -  2462.0 0.037  
CC 15C 2422.0  -  2452.0 0.0211  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.45 W/Kg, Body 0.17 W/Kg and simultaneous transmission 0.56 W/Kg, respectively.

This device supports 20MHz and 40MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application KFIpBqurk58qV9Aka16V7Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 11/01/2021

Application Dated: 11/01/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Digital Transmission System
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0005  
CC 15C 2412.0  -  2462.0 0.037  
CC 15C 2422.0  -  2452.0 0.0211  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.45 W/Kg, Body 0.17 W/Kg and simultaneous transmission 0.56 W/Kg, respectively.

This device supports 20MHz and 40MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application HKiE+1liAFa8P4XTMxPMeA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 02/03/2021

Application Dated: 02/03/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Digital Transmission System
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0005  
CC 15C 2412.0  -  2462.0 0.037  
CC 15C 2422.0  -  2452.0 0.0211  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.45 W/Kg, Body 0.17 W/Kg and simultaneous transmission 0.56 W/Kg, respectively.

This device supports 20MHz and 40MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application HKiE+1liAFa8P4XTMxPMeA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 02/03/2021

Application Dated: 02/03/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Digital Transmission System
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0005  
CC 15C 2412.0  -  2462.0 0.037  
CC 15C 2422.0  -  2452.0 0.0211  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.45 W/Kg, Body 0.17 W/Kg and simultaneous transmission 0.56 W/Kg, respectively.

This device supports 20MHz and 40MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application GGrQpKnnsgf3tTGiZsWwYA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 11/01/2021

Application Dated: 11/01/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application GGrQpKnnsgf3tTGiZsWwYA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 11/01/2021

Application Dated: 11/01/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application enOu6v3b8VUiSTYRYbtl3A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  SGS North America, Inc.
620 Old Peachtree Road NW Suite 100
Suwanee, GA 30024
Date of Grant: 02/03/2021

Application Dated: 02/03/2021
PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Payment Cell Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0087  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.11 W/Kg, Body 0.04 W/Kg and simultaneous transmission 0.48 W/Kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application enOu6v3b8VUiSTYRYbtl3A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

PAX Technology Limited
Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour
Hong Kong,
China
  Date of Grant: 02/03/2021

Application Dated: 02/03/2021
 
Attention: Jenna Tan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V5PM50
Name of Grantee:  PAX Technology Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Mobile Payment Cell Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0087  

Output power listed is conducted. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for head and body worn operation has been tested and meets the FCC RF exposure guidelines when used with the listed accessories designated and must provide at least 1.0 cm separation between the device and the user's body for this product as shown in the filing. End users must be informed of the head and body worn requirements for satisfying RF exposure compliance. This device must be restricted to work related operations in non-occupational/uncontrolled RF exposure environment. SAR was evaluated for head, body worn and simultaneous transmission operating modes and found not to exceed the SAR 1g average limit of 1.6 W/Kg for non-occupational/uncontrolled RF exposure environment. Maximum SAR values reported are: Head 0.11 W/Kg, Body 0.04 W/Kg and simultaneous transmission 0.48 W/Kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: