FCC ID V7TA300
Wireless N300 Universal Range Extender
by SHENZHEN TENDA TECHNOLOGY CO., LTD.
Grantee Code: V7T Product Code: A300
Latest application date: 2014-07-31
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2014-07-31 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2014-07-31 | PDF 2.4 MB |
| internal photo | Internal Photos | 2014-07-31 | PDF 785.9 KB |
| External Photo | External Photos | 2014-07-31 | PDF 488.6 KB |
| iD Label | ID Label/Location Info | 2014-07-31 | PDF 121.6 KB |
| Test Setup Photo | Test Setup Photos | 2014-07-31 | PDF 470 KB |
| test report1 | Test Report | 2014-07-31 | PDF 2.5 MB |
| test report2 | Test Report | 2014-07-31 | PDF 2.8 MB |
| Confidential Letter | Cover Letter(s) | 2014-07-31 | PDF 107.5 KB |
| POA | Cover Letter(s) | 2014-07-31 | PDF 104 KB |
| ad-hoc | Cover Letter(s) | 2014-07-31 | PDF 89.9 KB |
| RF Exposure | RF Exposure Info | 2014-07-31 | PDF 69.6 KB |
Application Information
| Application ID | 8Au9k+lWwWhAPh3ibyaMlw== |
|---|---|
| Final Action Date | 2014-07-31 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004265807 |
| Model | A300 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wireless N300 Universal Range Extender |
| Responsible Party | Shen Yue, Engineer, cert@tenda.cn |
| Test Firm | Daisy Dai, BTL Inc., daisy.dai@btl.org.cn |
| TCB Email | bentje.holger@phoenix-testlab.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power listed is conducted. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. This device has 20 and 40 MHz BW modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 8Au9k+lWwWhAPh3ibyaMlw== | 2014-07-31 | Original Equipment |
Grants
TCB Grant - Application 8Au9k+lWwWhAPh3ibyaMlw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 07/31/2014 Application Dated: 07/31/2014 |
| SHENZHEN TENDA TECHNOLOGY CO., LTD. |
| 6-8 Floor, Tower E3, |
| No. 1001, Zhongshanyuan Road,Nanshan District, |
| Shenzhen, 518052 China |
| Attention: Shen Yue , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | V7TA300 |
| Name of Grantee: | SHENZHEN TENDA TECHNOLOGY CO., LTD. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless N300 Universal Range Extender |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.3673 | |||
| 15C | 2422.0 - 2452.0 | 0.3565 |
| Output Power listed is conducted. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. This device has 20 and 40 MHz BW modes. |
EAS Grant - Application 8Au9k+lWwWhAPh3ibyaMlw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SHENZHEN TENDA TECHNOLOGY CO., LTD. 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road,Nanshan District, Shenzhen, 518052 China |
Date of Grant: 07/31/2014 Application Dated: 07/31/2014 |
| Attention: Shen Yue , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | V7TA300 |
| Name of Grantee: | SHENZHEN TENDA TECHNOLOGY CO., LTD. |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless N300 Universal Range Extender |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.3673 | |||
| 15C | 2422.0 - 2452.0 | 0.3565 |
| Output Power listed is conducted. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance. This device has 20 and 40 MHz BW modes. |