FCC ID V7TI24

AC1200 Wave2 Gigabit Access Point

by SHENZHEN TENDA TECHNOLOGY CO., LTD.

Grantee Code: V7T   Product Code: I24
Latest application date: 2019-03-07

FCC ID Device Details

FCC IDV7TI24
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeV7T
Product CodeI24
Applicant BusinessSHENZHEN TENDA TECHNOLOGY CO., LTD. 🇨🇳
Related Domains tenda.cn
Equipment ClassAC1200 Wave2 Gigabit Access Point
Test FirmBTL Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2019-03-07
2412-2462 MHzOriginal Equipment2019-03-07

Exhibits

DocumentTypeAvailableFile
15_i24 UserManUsers Manual2019-03-07PDF 4.2 MB
09_i24 IntPhoInternal Photos2019-03-07PDF 1.3 MB
08_i24 ExtPhoExternal Photos2019-03-07PDF 225.4 KB
06-07_i24 LabelSmpl-LocID Label/Location Info2019-03-07PDF 446.7 KB
17_i24 AntSpecOperational Description2019-03-07PDF 93.4 KB
10_i24 TSupTest Setup Photos2019-03-07PDF 978.3 KB
14_i24 TestRpt DTS p1 r1Test Report2019-03-07PDF 4.5 MB
14_i24 TestRpt DTS p2 r1Test Report2019-03-07PDF 4.7 MB
14_i24 TestRpt NII p1Test Report2019-03-07PDF 4.8 MB
14_i24 TestRpt NII p2Test Report2019-03-07PDF 4.8 MB
14_i24 TestRpt NII p3Test Report2019-03-07PDF 1.3 MB
18_i24 RFExpRF Exposure Info2019-03-07PDF 251.5 KB
12_i24 BlkDia Metadata onlyBlock DiagramPDF 223.1 KB
13_i24 Schem Metadata onlySchematicsPDF 528.7 KB
11_i24 OpDes r1 Metadata onlyOperational DescriptionPDF 101.4 KB

Application Information

Application IDz8mDhl6iSRYP1yh7NWu5eQ==
Final Action Date2019-03-07
Application PurposeOriginal Equipment
Applicant FRN0017645623
ModelI24
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionAC1200 Wave2 Gigabit Access Point
Responsible PartyShen Yue, Engineer, cert@tenda.cn , 86-755-27657098
Test FirmSophia Huang, BTL Inc., Sophia.huang@newbtl.com , +86-769-83183000
TCB Emailjoergkusig@eurofins.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device supports 20, 40 and 80MHz bandwidth operation.

Applications

Application IDDatePurpose
z8mDhl6iSRYP1yh7NWu5eQ==2019-03-07Original Equipment
0jhygwPekVRLRoWqa4Hp2A==2019-03-07Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.520000015C41, CC, MO
5180-5240 MHz0.515E41, CC, MO
5745-5825 MHz0.43115E41, CC, MO

Grants

TCB Grant - Application z8mDhl6iSRYP1yh7NWu5eQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 03/07/2019

Application Dated: 03/07/2019
SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3,
No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI24
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC1200 Wave2 Gigabit Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
41 CC MO 15E 5180.0  -  5240.0 0.5  
41 CC MO 15E 5745.0  -  5825.0 0.431  

Power listed is conducted. This device supports 20, 40 and 80MHz bandwidth operation.

41: Installation of this device must not be readily accessible to human subjects closer than 20 cm.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application z8mDhl6iSRYP1yh7NWu5eQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
  Date of Grant: 03/07/2019

Application Dated: 03/07/2019
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI24
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AC1200 Wave2 Gigabit Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
41 CC MO 15E 5180.0  -  5240.0 0.5  
41 CC MO 15E 5745.0  -  5825.0 0.431  

Power listed is conducted. This device supports 20, 40 and 80MHz bandwidth operation.


41: Installation of this device must not be readily accessible to human subjects closer than 20 cm.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 0jhygwPekVRLRoWqa4Hp2A==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 03/07/2019

Application Dated: 03/07/2019
SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3,
No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI24
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Digital Transmission System
Notes: AC1200 Wave2 Gigabit Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
41 CC MO 15C 2412.0  -  2462.0 0.52  

Power listed is conducted. This device supports 20 and 40MHz bandwidth operation.

41: Installation of this device must not be readily accessible to human subjects closer than 20 cm.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 0jhygwPekVRLRoWqa4Hp2A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
  Date of Grant: 03/07/2019

Application Dated: 03/07/2019
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI24
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Digital Transmission System
Notes: AC1200 Wave2 Gigabit Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
41 CC MO 15C 2412.0  -  2462.0 0.52  

Power listed is conducted. This device supports 20 and 40MHz bandwidth operation.


41: Installation of this device must not be readily accessible to human subjects closer than 20 cm.
CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: