FCC ID V7TI27

AX3000 Wi-Fi 6 Ceiling Access Point

by SHENZHEN TENDA TECHNOLOGY CO., LTD.

Grantee Code: V7T   Product Code: I27
Latest application date: 2023-05-16

FCC ID Device Details

FCC IDV7TI27
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeV7T
Product CodeI27
Applicant BusinessSHENZHEN TENDA TECHNOLOGY CO., LTD. 🇨🇳
Related Domains tenda.cn
Equipment ClassAX3000 Wi-Fi 6 Ceiling Access Point
Test FirmCHINA CERTIFICATION ICT CO., LTD (DONGGUAN)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2023-05-16
2412-2462 MHzOriginal Equipment2023-05-16

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-05-16PDF 1.1 MB
Internal PhotosInternal Photos2023-05-16PDF 1.4 MB
External PhotosExternal Photos2023-05-16PDF 1.1 MB
Label & Label LocationID Label/Location Info2023-05-16PDF 67.4 KB
Test Setup PhotosTest Setup Photos2023-05-16PDF 355.2 KB
Test Setup PhotosTest Setup Photos2023-05-16PDF 363.2 KB
Test Setup Photos - DFSTest Setup Photos2023-05-16PDF 121.1 KB
Antenna SpecificationTest Report2023-05-16PDF 864.3 KB
Test ReportTest Report2023-05-16PDF 1.8 MB
Test Report - 5G Wi-FiTest Report2023-05-16PDF 3.4 MB
Test Report - DFSTest Report2023-05-16PDF 1.2 MB
2.911 (d)(5)(i)(ii) Attestation StatementAttestation Statements2023-05-16PDF 66.8 KB
Declaration LetterAttestation Statements2023-05-16PDF 97.6 KB
US Agent Attestation LetterAttestation Statements2023-05-16PDF 64.4 KB
FCC Agent Authorization LetterCover Letter(s)2023-05-16PDF 58.8 KB
FCC Long-term Confidential RequestCover Letter(s)2023-05-16PDF 59.8 KB
RF ExposureRF Exposure Info2023-05-16PDF 127.3 KB
RF ExposureRF Exposure Info2023-05-16PDF 127.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 156.7 KB
Schematics Metadata onlySchematicsPDF 390.8 KB
Circuit Description Metadata onlyOperational DescriptionPDF 82.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 82.7 KB
Software Security Description Metadata onlySDR Software/Security InfPDF 362.1 KB

Application Information

Application IDTx6eGesAfJ70INJeBXBeMw==
Final Action Date2023-05-16
Application PurposeOriginal Equipment
Applicant FRN0017645623
ModelI27
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionAX3000 Wi-Fi 6 Ceiling Access Point
Responsible PartyShen Yue, Engineer, cert@tenda.cn , 86-755-27657098
Test FirmTanie Ou, CHINA CERTIFICATION ICT CO., LTD (DONGGUAN), qa@ccttt.com.cn , 0086 0769 86858888
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This product supports 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes.

Applications

Application IDDatePurpose
Tx6eGesAfJ70INJeBXBeMw==2023-05-16Original Equipment
PE/Co8orJjIEER7BuFGNEQ==2023-05-16Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.479000015CCC, MO
5180-5240 MHz0.27415ECC, MO
5260-5320 MHz0.09915ECC, MO, ND
5745-5825 MHz0.24615ECC, MO

Grants

TCB Grant - Application Tx6eGesAfJ70INJeBXBeMw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 05/16/2023

Application Dated: 05/12/2023
SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3,
No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI27
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AX3000 Wi-Fi 6 Ceiling Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.274  
CC MO ND 15E 5260.0  -  5320.0 0.099  
CC MO 15E 5745.0  -  5825.0 0.246  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This product supports 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

EAS Grant - Application Tx6eGesAfJ70INJeBXBeMw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
  Date of Grant: 05/16/2023

Application Dated: 05/12/2023
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI27
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AX3000 Wi-Fi 6 Ceiling Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.274  
CC MO ND 15E 5260.0  -  5320.0 0.099  
CC MO 15E 5745.0  -  5825.0 0.246  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This product supports 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application PE/Co8orJjIEER7BuFGNEQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 05/16/2023

Application Dated: 05/12/2023
SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3,
No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI27
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Digital Transmission System
Notes: AX3000 Wi-Fi 6 Ceiling Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.479  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The device support 20 MHz and 40 MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application PE/Co8orJjIEER7BuFGNEQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SHENZHEN TENDA TECHNOLOGY CO., LTD.
6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road,Nanshan District,
Shenzhen, 518052
China
  Date of Grant: 05/16/2023

Application Dated: 05/12/2023
 
Attention: Shen Yue , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V7TI27
Name of Grantee:  SHENZHEN TENDA TECHNOLOGY CO., LTD.
Equipment Class: Digital Transmission System
Notes: AX3000 Wi-Fi 6 Ceiling Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.479  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The device support 20 MHz and 40 MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: