FCC ID V8YFW181RG38002W

WiMAX CPE Device

by Accton Wireless Broadband Corp.

Grantee Code: V8Y   Product Code: FW181RG38002W
Latest application date: 2010-09-06

FCC ID Device Details

FCC IDV8YFW181RG38002W
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeV8Y
Product CodeFW181RG38002W
Applicant BusinessAccton Wireless Broadband Corp. 🇹🇼
Related Domains awbnetworks.com
Equipment ClassWiMAX CPE Device
Test FirmUL VS Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
3652.5-3672.5 MHzOriginal Equipment2010-09-06

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2010-09-06PDF 32.5 KB
Internal photosInternal Photos2010-09-06PDF 79 KB
External photos 01External Photos2010-09-06PDF 28.4 KB
External photos 02External Photos2010-09-06PDF 16.6 KB
Label and locationID Label/Location Info2010-09-06PDF 26.4 KB
Test photosTest Setup Photos2010-09-06PDF 60.5 KB
Test Report 01Test Report2010-09-06PDF 485.7 KB
Test Report FinalTest Report2010-09-06PDF 966.1 KB
Test Report statementTest Report2010-09-06PDF 32.1 KB
Contention Based ProtocolAttestation Statements2010-09-06PDF 34.2 KB
Agent AuthorisationCover Letter(s)2010-09-06PDF 23.9 KB
ConfidentialityCover Letter(s)2010-09-06PDF 17.3 KB
MPE EvaluationRF Exposure Info2010-09-06PDF 26.7 KB

Application Information

Application IDME3VWxNoRKb3xLbhwyPKfQ==
Final Action Date2010-09-06
Application PurposeOriginal Equipment
Applicant FRN0017693334
ModelFW181RG38002W
Frequency Range3652.5-3672.5 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionWiMAX CPE Device
Responsible PartyAbby Wei, Engineer, abby_wei@awbnetworks.com , 886-3-577-0023
AgentCharlie Charlie Charlie, Sulis Consultants Ltd, charlie@sulisconsultants.com , +44 7946 624317
Technical ContactCharlie Blackham, Sulis Consultants Ltd, charlie@sulisconsultants.com
Test FirmJohn Newell, UL VS Ltd, john.newell@ul.com , 00-44-1256-312000
TCB Emailhotline@atcb.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput Power listed is EIRP. The device must be professionally installed by qualified personnel and fixed mounted on a permanent structure. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
ME3VWxNoRKb3xLbhwyPKfQ==2010-09-06Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
3652.5-3672.5 MHz0.6920.2ppm5M00D1D9RS
3655-3670 MHz0.2750.2ppm10M0D1D9RS

Grants

TCB Grant - Application ME3VWxNoRKb3xLbhwyPKfQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 09/06/2010

Application Dated: 08/27/2010
Accton Wireless Broadband Corp.
3F, No. 1 Creation Rd. III, Science-based Industri
Hsinchu, 30077
Taiwan
 
Attention: Abby Wei , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V8YFW181RG38002W
Name of Grantee:  Accton Wireless Broadband Corp.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX CPE Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
RS 90 3652.5  -  3672.5 0.692 0.2  PM 5M00D1D
RS 90 3655.0  -  3670.0 0.275 0.2  PM 10M0D1D

Output Power listed is EIRP. The device must be professionally installed by qualified personnel and fixed mounted on a permanent structure. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

RS: This device incorporates a restricted contention based protocol. It is not capable of avoiding co frequency interference with devices using all other types of contention-based protocols. Operation is restricted to the 3650-3675 MHz band.

EAS Grant - Application ME3VWxNoRKb3xLbhwyPKfQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Accton Wireless Broadband Corp.
3F, No. 1 Creation Rd. III, Science-based Industri
Hsinchu, 30077
Taiwan
  Date of Grant: 09/06/2010

Application Dated: 08/27/2010
 
Attention: Abby Wei , Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  V8YFW181RG38002W
Name of Grantee:  Accton Wireless Broadband Corp.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX CPE Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
RS 90 3652.5  -  3672.5 0.692 0.2  PM 5M00D1D
RS 90 3655.0  -  3670.0 0.275 0.2  PM 10M0D1D

Output Power listed is EIRP. The device must be professionally installed by qualified personnel and fixed mounted on a permanent structure. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).


RS: This device incorporates a restricted contention based protocol. It is not capable of avoiding co frequency interference with devices using all other types of contention-based protocols. Operation is restricted to the 3650-3675 MHz band.

Mail To: