FCC ID V92RGST2
Short range digital transmitter
by GE Energy NZ Ltd
Grantee Code: V92 Product Code: RGST2
Latest application date: 2014-12-11
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2405-2460 MHz | Original Equipment | 2014-12-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2014-12-11 | PDF 4.7 MB |
| Internal Photos | Internal Photos | 2014-12-11 | PDF 759 KB |
| External Photos | External Photos | 2014-12-11 | PDF 194.7 KB |
| Label Info | ID Label/Location Info | 2014-12-11 | PDF 179.5 KB |
| Test Setup Photos | Test Setup Photos | 2014-12-11 | PDF 848.4 KB |
| Test Report | Test Report | 2014-12-11 | PDF 2.8 MB |
| Authorization Letter | Cover Letter(s) | 2014-12-11 | PDF 52.4 KB |
| Confidentiality Letter | Cover Letter(s) | 2014-12-11 | PDF 28.5 KB |
| RF Exposure Info | RF Exposure Info | 2014-12-11 | PDF 246.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 34.5 KB | |
| Schematics Metadata only | Schematics | PDF 1.5 MB | |
| Operational Description Metadata only | Operational Description | PDF 335.7 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 22.9 KB |
Application Information
| Application ID | /emWrRjCHxBnhbe/LPWvIg== |
|---|---|
| Final Action Date | 2014-12-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017719832 |
| Model | RGST2 |
| Frequency Range | 2405-2460 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Short range digital transmitter |
| Responsible Party | Brian Stephen Wood, Design Engineer, brianstephen.wood@ge.com |
| Test Firm | Andrew Cutler, EMC Technologies NZ Ltd., auklab@ihug.co.nz |
| TCB Email | tei@timcoengr.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| /emWrRjCHxBnhbe/LPWvIg== | 2014-12-11 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2405-2460 MHz | 0.0550000 | 15C |
Grants
TCB Grant - Application /emWrRjCHxBnhbe/LPWvIg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 12/11/2014 Application Dated: 12/11/2014 |
| GE Energy NZ Ltd |
| Level 2, 22 Moorhouse Ave |
| P.O. Box 9797, |
| Christchurch, New Zealand |
| Attention: Brian Wood , Design Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | V92RGST2 |
| Name of Grantee: | GE Energy NZ Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Short range digital transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2460.0 | 0.055 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application /emWrRjCHxBnhbe/LPWvIg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GE Energy NZ Ltd Level 2, 22 Moorhouse Ave P.O. Box 9797, Christchurch, New Zealand |
Date of Grant: 12/11/2014 Application Dated: 12/11/2014 |
| Attention: Brian Wood , Design Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | V92RGST2 |
| Name of Grantee: | GE Energy NZ Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Short range digital transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2405.0 - 2460.0 | 0.055 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |