FCC ID VAWSKSN-I25-CO

iDEN RF Repeater

by SK Telesys Co.,Ltd.

Grantee Code: VAW   Product Code: SKSNI25CO
Latest application date: 2007-06-15

FCC ID Device Details

FCC IDVAWSKSN-I25-CO
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVAW
Product CodeSKSNI25CO
Applicant BusinessSK Telesys Co.,Ltd. 🇰🇷
Related Domains sktelesys.com
Equipment ClassiDEN RF Repeater
Test FirmBWS TECH INC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-824 MHzOriginal Equipment2007-06-15

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2007-06-15PDF 1.1 MB
Internal PhotosInternal Photos2007-06-15PDF 2.3 MB
External PhotosExternal Photos2007-06-15PDF 188.4 KB
ID Label InfoID Label/Location Info2007-06-15PDF 63.2 KB
Test Setup PhotosTest Setup Photos2007-06-15PDF 195.1 KB
Test ReportTest Report2007-06-15PDF 2.2 MB
Confidentiality RequestCover Letter(s)2007-06-15PDF 122 KB

Application Information

Application IDZW3v+1U0IkAiCWNSpRbfWw==
Final Action Date2007-06-15
Application PurposeOriginal Equipment
Applicant FRN0016445090
ModelSKSN-I25-CO
Frequency Range806-824 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptioniDEN RF Repeater
Responsible PartyDong Moon Woo, zsmlee@sktelesys.com , 82-31-786-5706
Test FirmCheol-Ho Lee, BWS TECH INC, chlee@bws.co.kr , 82-31-333-5997
TCB Emailkknoerig@emcc.de
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPart 90 iDEN repeater. Power output listed is conducted per channel. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. Downlink (indoor) grant conditions - The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). Uplink (outdoor) grant conditions - The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Applications

Application IDDatePurpose
ZW3v+1U0IkAiCWNSpRbfWw==2007-06-15Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
806-824 MHz0.3160.1ppmGXW90, 9
817-824 MHz0.3160.1ppmGXW90, 9
851-869 MHz0.3160.1ppmGXW9
862-869 MHz0.3160.1ppmGXW9
896-901 MHz0.3160.1ppmGXW9
935-940 MHz0.3160.1ppmGXW9

Grants

TCB Grant - Application ZW3v+1U0IkAiCWNSpRbfWw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  EMCCert Dr. Rasek GmbH
Stoernhofer Berg 15
91364 Unterleinleiter,
Germany
Date of Grant: 06/15/2007

Application Dated: 06/15/2007
SK Telesys Co.,Ltd.
6, Euljiro-2Ga, Jung-Gu, Seoul 100-844,
South Korea
Seoul, 463-825
South Korea
 
Attention: Dong Moon Woo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VAWSKSN-I25-CO
Name of Grantee:  SK Telesys Co.,Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: iDEN RF Repeater
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 0.316 0.1  PM GXW
90 817.0  -  824.0 0.316 0.1  PM GXW
90 896.0  -  901.0 0.316 0.1  PM GXW
90 851.0  -  869.0 0.316 0.1  PM GXW
90 862.0  -  869.0 0.316 0.1  PM GXW
90 935.0  -  940.0 0.316 0.1  PM GXW

Part 90 iDEN repeater. Power output listed is conducted per channel. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Downlink (indoor) grant conditions - The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Uplink (outdoor) grant conditions - The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).


EAS Grant - Application ZW3v+1U0IkAiCWNSpRbfWw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SK Telesys Co.,Ltd.
6, Euljiro-2Ga, Jung-Gu, Seoul 100-844, South Korea
Seoul, 463-825
South Korea
  Date of Grant: 06/15/2007

Application Dated: 06/15/2007
 
Attention: Dong Moon Woo

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VAWSKSN-I25-CO
Name of Grantee:  SK Telesys Co.,Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: iDEN RF Repeater
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 0.316 0.1  PM GXW
90 817.0  -  824.0 0.316 0.1  PM GXW
90 896.0  -  901.0 0.316 0.1  PM GXW
90 851.0  -  869.0 0.316 0.1  PM GXW
90 862.0  -  869.0 0.316 0.1  PM GXW
90 935.0  -  940.0 0.316 0.1  PM GXW

Part 90 iDEN repeater. Power output listed is conducted per channel. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Downlink (indoor) grant conditions - The antenna used for this transmitter is to be fixed-mounted on indoor permanent structures providing a separation distance of at least 20 cm from all persons during normal operation. The maximum radiated output power must satisfy the MPE Categorical Exclusion Requirements of 2.1091. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Uplink (outdoor) grant conditions - The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).



Mail To:


EA915297