FCC ID VDE-G0071690

Gateway to monitor and manage Home Standby Generators

by Generac Power Systems Inc.

Grantee Code: VDE   Product Code: G0071690
Latest application date: 2018-11-07

FCC ID Device Details

FCC IDVDE-G0071690
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVDE
Product CodeG0071690
Applicant BusinessGenerac Power Systems Inc. 🇺🇸
Related Domains generac.com
Equipment ClassGateway to monitor and manage Home Standby Generators
Test FirmCETECOM Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
706.5-713.5 MHzOriginal Equipment2018-11-07

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2019-04-22PDF 2.7 MB
Internal PhotosInternal Photos2019-04-22PDF 464.9 KB
External photosExternal Photos2019-04-22PDF 454.5 KB
LabelID Label/Location Info2018-11-07PDF 63.1 KB
Label locationID Label/Location Info2018-11-07PDF 1.9 MB
Test-Report-FCC-Part-22-1Test Report2018-11-07PDF 2 MB
Test-Report-FCC-Part-22-2Test Report2018-11-07PDF 1.3 MB
Test-Report-FCC-Part-22-3Test Report2018-11-07PDF 1.4 MB
Test-Report-FCC-Part-22-L-3Test Report2018-11-07PDF 1.5 MB
Test-Report-FCC-Part-24-1Test Report2018-11-07PDF 2.8 MB
Test-Report-FCC-Part-24-2Test Report2018-11-07PDF 2.5 MB
Test-Report-FCC-Part-24-3Test Report2018-11-07PDF 1.6 MB
Test-Report-FCC-Part-27-1Test Report2018-11-07PDF 2.2 MB
Test-Report-FCC-Part-27-2Test Report2018-11-07PDF 2.6 MB
Test-Report-FCC-Part-27-L-1Test Report2018-11-07PDF 2.9 MB
Test-Report-FCC-Part-27-L-2Test Report2018-11-07PDF 2 MB
ConfidentialityCover Letter(s)2018-11-07PDF 258.9 KB
Module RF ExposureRF Exposure Info2018-11-07PDF 114.8 KB
Schematics Metadata onlySchematicsPDF 1.3 MB
Operational description Metadata onlyOperational DescriptionPDF 411.3 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 294.3 KB

Application Information

Application IDNi6YX7zQz5GydvmzvhPvfw==
Final Action Date2018-11-07
Application PurposeOriginal Equipment
Applicant FRN0021621941
ModelG0071690
Frequency Range706.5-713.5 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionGateway to monitor and manage Home Standby Generators
Responsible PartyJeffrey Jonas, Senior Staff Engineer, Jeffrey.Jonas@generac.com , 2625444811
AgentJames James James, Cetecom Inc., Franz.Engert@cetecom.com , 4085866205
Test FirmKevin Wang, CETECOM Inc., kevin.wang@cetecom.com , 408-586-6271
TCB Emailjames.donnellan@cetecom.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date04/22/2019
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower out is RMS radiated ERP from the antenna below 1GHz and RMS radiated EIRP above 1GHz. Use of a different antenna from the one provided in this grant will void the equipment authorization.

Applications

Application IDDatePurpose
Ni6YX7zQz5GydvmzvhPvfw==2018-11-07Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
706.5-713.5 MHz0.3820.027ppm4M50G7D27BC
709-711 MHz0.380.027ppm8M97G7D27BC
779.5-784.5 MHz0.3750.027ppm4M51G7D27BC
782 MHz0.3890.027ppm9M01G7D27BC
824.7-848.3 MHz0.3860.025ppm1M09G7D22HBC
829-844 MHz0.4010.025ppm9M01G7D22HBC
1710.7-1754.3 MHz0.5560.015ppm1M09G7D27BC
1720-1745 MHz0.5630.015ppm18M0G7D27BC
1850.7-1909.3 MHz0.5130.015ppm1M09G7D24EBC
1852.4-1907.6 MHz0.7710.015ppm4M14F9W24EBC
1860-1900 MHz0.5370.015ppm18M0G7D24EBC

Grants

TCB Grant - Application Ni6YX7zQz5GydvmzvhPvfw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM Inc.
411 Dixon Landing Road
Milpitas, CA 95035
Date of Grant: 11/07/2018

Application Dated: 10/23/2018
Generac Power Systems Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189
 
Attention: Jeffrey Jonas , Senior Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VDE-G0071690
Name of Grantee:  Generac Power Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Gateway to monitor and manage Home Standby Generators
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 826.4  -  846.6 0.508 0.025  PM 4M11F9W
BC 22H 824.7  -  848.3 0.386 0.025  PM 1M09G7D
BC 22H 829.0  -  844.0 0.401 0.025  PM 9M01G7D
BC 27 779.5  -  784.5 0.375 0.027  PM 4M51G7D
BC 27 782.0  -  782.0 0.389 0.027  PM 9M01G7D
BC 27 706.5  -  713.5 0.382 0.027  PM 4M50G7D
BC 27 709.0  -  711.0 0.38 0.027  PM 8M97G7D
BC 27 1710.7  -  1754.3 0.556 0.015  PM 1M09G7D
BC 27 1720.0  -  1745.0 0.563 0.015  PM 18M0G7D
BC 24E 1852.4  -  1907.6 0.771 0.015  PM 4M14F9W
BC 24E 1850.7  -  1909.3 0.513 0.015  PM 1M09G7D
BC 24E 1860.0  -  1900.0 0.537 0.015  PM 18M0G7D

Power out is RMS radiated ERP from the antenna below 1GHz and RMS radiated EIRP above 1GHz. Use of a different antenna from the one provided in this grant will void the equipment authorization.

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application Ni6YX7zQz5GydvmzvhPvfw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Generac Power Systems Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189
United States
  Date of Grant: 11/07/2018

Application Dated: 10/23/2018
 
Attention: Jeffrey Jonas , Senior Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VDE-G0071690
Name of Grantee:  Generac Power Systems Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Gateway to monitor and manage Home Standby Generators
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 826.4  -  846.6 0.508 0.025  PM 4M11F9W
BC 22H 824.7  -  848.3 0.386 0.025  PM 1M09G7D
BC 22H 829.0  -  844.0 0.401 0.025  PM 9M01G7D
BC 27 779.5  -  784.5 0.375 0.027  PM 4M51G7D
BC 27 782.0  -  782.0 0.389 0.027  PM 9M01G7D
BC 27 706.5  -  713.5 0.382 0.027  PM 4M50G7D
BC 27 709.0  -  711.0 0.38 0.027  PM 8M97G7D
BC 27 1710.7  -  1754.3 0.556 0.015  PM 1M09G7D
BC 27 1720.0  -  1745.0 0.563 0.015  PM 18M0G7D
BC 24E 1852.4  -  1907.6 0.771 0.015  PM 4M14F9W
BC 24E 1850.7  -  1909.3 0.513 0.015  PM 1M09G7D
BC 24E 1860.0  -  1900.0 0.537 0.015  PM 18M0G7D

Power out is RMS radiated ERP from the antenna below 1GHz and RMS radiated EIRP above 1GHz. Use of a different antenna from the one provided in this grant will void the equipment authorization.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: