FCC ID VDQIGM-01
Medical Alert System
by Daviscomms (S) Pte Ltd
Grantee Code: VDQ Product Code: IGM01
Latest application date: 2009-11-09
FCC ID Device Details
| FCC ID | VDQIGM-01 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | VDQ |
| Product Code | IGM01 |
| Applicant Business | Daviscomms (S) Pte Ltd 🇸🇬 |
| Related Domains | |
| Equipment Class | Medical Alert System |
| Test Firm | SGS Taiwan Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 433.92 MHz | Original Equipment | 2009-11-09 |
| 824.2-848.8 MHz | Original Equipment | 2009-11-09 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2009-11-09 | PDF 929.9 KB |
| Users Manual Rev1 | Users Manual | 2009-11-09 | PDF 922.1 KB |
| Internal Photo | Internal Photos | 2009-11-09 | PDF 171.8 KB |
| External Photo | External Photos | 2009-11-09 | PDF 75.8 KB |
| FCCID Labeling | ID Label/Location Info | 2009-11-09 | PDF 20.4 KB |
| SAR Setup Photos Rev02 | Test Setup Photos | 2009-11-09 | PDF 217.2 KB |
| Setup Photo | Test Setup Photos | 2009-11-09 | PDF 111.3 KB |
| EH-2009-90047 _Part 22H+24E | Test Report | 2009-11-09 | PDF 787.1 KB |
| ER-2009-90048_ Part15.231 | Test Report | 2009-11-09 | PDF 435.8 KB |
| SAR Test Report OET65 Rev01 | RF Exposure Info | 2009-11-09 | PDF 3.4 MB |
| Authority to Act as Agent | Cover Letter(s) | 2009-11-09 | PDF 24.8 KB |
| DoC Letter | Cover Letter(s) | 2009-11-09 | PDF 24.4 KB |
| confidentiality letter | Cover Letter(s) | 2009-11-09 | PDF 21.4 KB |
Application Information
| Application ID | wTcv4VpLfmVB8Lnc1gQ0Tw== |
|---|---|
| Final Action Date | 2009-11-09 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0016568214 |
| Model | IGM-01 |
| Frequency Range | 433.92 MHz |
| Equipment Class | DSC - Part 15 Security/Remote Control Transmitter |
| Device Description | Medical Alert System |
| Responsible Party | Ramasamy Lakshmanan, Engineer, rama@daviscomms.com.sg |
| Technical Contact | Vincent Su, SGS Taiwan Ltd., Vincent.su@sgs.com |
| Test Firm | Nelson Bai, SGS Taiwan Ltd., nelson.bai@sgs.com |
| TCB Email | hotline@atcb.com |
| TCB Scope | A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| wTcv4VpLfmVB8Lnc1gQ0Tw== | 2009-11-09 | Original Equipment |
| 9GimyxbopJM/YHvTZ/BXYw== | 2009-11-09 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application wTcv4VpLfmVB8Lnc1gQ0Tw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 11/09/2009 Application Dated: 11/03/2009 |
| Daviscomms (S) Pte Ltd |
| Blk 70 Ubi Crescent #01-07, |
| Ubi Techpark |
| Singapore, 408570 Singapore |
| Attention: Ramasamy Lakshmanan , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VDQIGM-01 |
| Name of Grantee: | Daviscomms (S) Pte Ltd |
| Equipment Class: | Part 15 Security/Remote Control Transmitter |
| Notes: | Medical Alert System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15.231 | 433.92 - 433.92 |
EAS Grant - Application wTcv4VpLfmVB8Lnc1gQ0Tw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Daviscomms (S) Pte Ltd Blk 70 Ubi Crescent #01-07, Ubi Techpark Singapore, 408570 Singapore |
Date of Grant: 11/09/2009 Application Dated: 11/03/2009 |
| Attention: Ramasamy Lakshmanan , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VDQIGM-01 |
| Name of Grantee: | Daviscomms (S) Pte Ltd |
| Equipment Class: | Part 15 Security/Remote Control Transmitter |
| Notes: | Medical Alert System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15.231 | 433.92 - 433.92 |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 11/09/2009 Application Dated: 11/03/2009 |
| Daviscomms (S) Pte Ltd |
| Blk 70 Ubi Crescent #01-07, |
| Ubi Techpark |
| Singapore, 408570 Singapore |
| Attention: Ramasamy Lakshmanan , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VDQIGM-01 |
| Name of Grantee: | Daviscomms (S) Pte Ltd |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Medical Alert System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 1.439 | 2.5 PM | 248KGXW |
| BC | 24E | 1850.2 - 1909.8 | 0.998 | 2.5 PM | 250KGXW |
| This device contains functions that are not operational in U.S. Territories. This filing is only applicable for Licensed operations. Power Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating conditions is limited to the specific belt clip tested for this filing, and belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: Body-worn: 0.76W/kg; Part 24: Body-worn: 0.87W/kg; |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application 9GimyxbopJM/YHvTZ/BXYw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Daviscomms (S) Pte Ltd Blk 70 Ubi Crescent #01-07, Ubi Techpark Singapore, 408570 Singapore |
Date of Grant: 11/09/2009 Application Dated: 11/03/2009 |
| Attention: Ramasamy Lakshmanan , Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VDQIGM-01 |
| Name of Grantee: | Daviscomms (S) Pte Ltd |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Medical Alert System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 1.439 | 2.5 PM | 248KGXW |
| BC | 24E | 1850.2 - 1909.8 | 0.998 | 2.5 PM | 250KGXW |
| This device contains functions that are not operational in U.S. Territories. This filing is only applicable for Licensed operations. Power Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating conditions is limited to the specific belt clip tested for this filing, and belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: Body-worn: 0.76W/kg; Part 24: Body-worn: 0.87W/kg; |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |