FCC ID VE4-MS2E

MS2E Module

by Axiometric, LLC

Grantee Code: VE4   Product Code: MS2E
Latest application date: 2011-09-28

FCC ID Device Details

FCC IDVE4-MS2E
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVE4
Product CodeMS2E
Applicant BusinessAxiometric, LLC 🇺🇸
Related Domains axiometric.com
Equipment ClassMS2E Module
Test FirmWashington Laboratories, Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.5-927 MHzOriginal Equipment2011-09-28

Exhibits

DocumentTypeAvailableFile
manualUsers Manual2011-09-28PDF 2 MB
internal photosInternal Photos2011-09-28PDF 324.2 KB
external photosExternal Photos2011-09-28PDF 324.2 KB
host labelID Label/Location Info2011-09-28PDF 64.6 KB
host label locationID Label/Location Info2011-09-28PDF 200.5 KB
labelID Label/Location Info2011-09-28PDF 291.1 KB
test report pt 1Schematics2011-09-28PDF 3 MB
test setup photosTest Setup Photos2011-09-28PDF 697 KB
test report pt 2Test Report2011-09-28PDF 4.4 MB
agent letterCover Letter(s)2011-09-28PDF 611.4 KB
confidentiality request letterCover Letter(s)2011-09-28PDF 1 MB
modular approval request letterCover Letter(s)2011-09-28PDF 486.9 KB
MPE infoRF Exposure Info2011-09-28PDF 249.4 KB

Application Information

Application IDFtyCPLdS5WZj5FtJxFZlkg==
Final Action Date2011-09-28
Application PurposeOriginal Equipment
Applicant FRN0016618514
Model-MS2E
Frequency Range902.5-927 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionMS2E Module
Responsible PartyFrank Moody, Principle, frank.moody@axiometric.com , 443-472-4154
AgentMichael Michael Michael, Washington Laboratories Ltd., cert@wll.com , 301-216-1500
Technical ContactSteven D. Koster, Washington Laboratories, Ltd., cert@wll.com , 301-216-1500
Test FirmJohn Repella, Washington Laboratories, Ltd., johnr@wll.com , 301-216-1500
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsLimited Modular Approval (LMA). Output Power listed is conducted. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. This Grant is valid only when this modular transmitter is installed by the Grantee into his products. Compliance of this modular transmitter in all final host configurations is the responsibility of the Grantee. Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
FtyCPLdS5WZj5FtJxFZlkg==2011-09-28Original Equipment

Equipment Authorization

FrequencyOutputRules
902.5-927 MHz0.414000015C

Grants

TCB Grant - Application FtyCPLdS5WZj5FtJxFZlkg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 09/28/2011

Application Dated: 09/27/2011
Axiometric, LLC
6200 Old Dobbin Lane
Suite 150
Columbia, MD 21045
 
Attention: Frank Moody , Principle

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VE4-MS2E
Name of Grantee:  Axiometric, LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: MS2E Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.5  -  927.0 0.414  

Limited Modular Approval (LMA). Output Power listed is conducted. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. This Grant is valid only when this modular transmitter is installed by the Grantee into his products. Compliance of this modular transmitter in all final host configurations is the responsibility of the Grantee. Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application FtyCPLdS5WZj5FtJxFZlkg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Axiometric, LLC
6200 Old Dobbin Lane Suite 150
Columbia, MD 21045
United States
  Date of Grant: 09/28/2011

Application Dated: 09/27/2011
 
Attention: Frank Moody , Principle

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VE4-MS2E
Name of Grantee:  Axiometric, LLC
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: MS2E Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.5  -  927.0 0.414  

Limited Modular Approval (LMA). Output Power listed is conducted. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. This Grant is valid only when this modular transmitter is installed by the Grantee into his products. Compliance of this modular transmitter in all final host configurations is the responsibility of the Grantee. Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: