FCC ID VG5WIN7249

WiMAX pBST base station transceiver

by Siemens Canada Limited

Grantee Code: VG5   Product Code: WIN7249
Latest application date: 2012-10-22

FCC ID Device Details

FCC IDVG5WIN7249
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVG5
Product CodeWIN7249
Applicant BusinessSiemens Canada Limited 🇨🇦
Related Domains siemens.com
Equipment ClassWiMAX pBST base station transceiver
Test FirmHermon Laboratories Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
4942.5-4987.5 MHzOriginal Equipment2012-10-22

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2012-10-22PDF 2.4 MB
Int. photosInternal Photos2012-10-22PDF 911 KB
Ext. photosExternal Photos2012-10-22PDF 78.8 KB
LabelID Label/Location Info2012-10-22PDF 202.2 KB
Test setup photosTest Setup Photos2012-10-22PDF 509.3 KB
Test reportTest Report2012-10-22PDF 956.9 KB
Conf. letterCover Letter(s)2012-10-22PDF 18.1 KB
Cover letterCover Letter(s)2012-10-22PDF 40.3 KB
DoACover Letter(s)2012-10-22PDF 38.2 KB
RF evalautionRF Exposure Info2012-10-22PDF 12.6 KB

Application Information

Application IDiqRtlFOkw6oM7mX5tHYnpw==
Final Action Date2012-10-22
Application PurposeOriginal Equipment
Applicant FRN0016678849
ModelWIN7249
Frequency Range4942.5-4987.5 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionWiMAX pBST base station transceiver
Responsible PartyNorman Lew, Senior Certification Engineer, norman.lew@siemens.com , 905-482-7217
Technical ContactMichael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com
Test FirmAlexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com , 972-4628-8001
TCB Emailcertification@telefication.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. Only Professional installation is allowed. The antenna used for this device must fixed-mounted on outdoor permanent structures. The antenna(s) used for this transmitter as is in this filling must be installed to provide a separation distance of at least 38 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than described in this filing. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
iqRtlFOkw6oM7mX5tHYnpw==2012-10-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
4942.5-4987.5 MHz0.4534200Hz5M00W7D90YMO
4947.5-4982.5 MHz0.414200Hz10M0W7D90YMO

Grants

TCB Grant - Application iqRtlFOkw6oM7mX5tHYnpw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 10/22/2012

Application Dated: 10/19/2012
Siemens Canada Limited
300 Applewood Crescent
Concord, L4K 5C7
Canada
 
Attention: Norman Lew , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VG5WIN7249
Name of Grantee:  Siemens Canada Limited
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX pBST base station transceiver
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 90Y 4942.5  -  4987.5 0.453 4200.0  Hz 5M00W7D
MO 90Y 4947.5  -  4982.5 0.41 4200.0  Hz 10M0W7D

Power output listed is conducted. Only Professional installation is allowed. The antenna used for this device must fixed-mounted on outdoor permanent structures. The antenna(s) used for this transmitter as is in this filling must be installed to provide a separation distance of at least 38 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than described in this filing. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application iqRtlFOkw6oM7mX5tHYnpw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Siemens Canada Limited
300 Applewood Crescent P.O. Box ,
Concord, L4K 5C7
Canada
  Date of Grant: 10/22/2012

Application Dated: 10/19/2012
 
Attention: Norman Lew , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VG5WIN7249
Name of Grantee:  Siemens Canada Limited
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: WiMAX pBST base station transceiver
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 90Y 4942.5  -  4987.5 0.453 4200.0  Hz 5M00W7D
MO 90Y 4947.5  -  4982.5 0.41 4200.0  Hz 10M0W7D

Power output listed is conducted. Only Professional installation is allowed. The antenna used for this device must fixed-mounted on outdoor permanent structures. The antenna(s) used for this transmitter as is in this filling must be installed to provide a separation distance of at least 38 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter other than described in this filing. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.