FCC ID VIDCENTRON
Electric Meter with Transceiver
by Arad Technologies Ltd.
Grantee Code: VID Product Code: CENTRON
Latest application date: 2007-09-27
FCC ID Device Details
| FCC ID | VIDCENTRON |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | VID |
| Product Code | CENTRON |
| Applicant Business | Arad Technologies Ltd. 🇮🇱 |
| Related Domains | |
| Equipment Class | Electric Meter with Transceiver |
| Test Firm | Hermon Laboratories Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 916.3 MHz | Original Equipment | 2007-09-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2007-09-27 | PDF 1.7 MB |
| Internal Photos | Internal Photos | 2007-09-27 | PDF 1.8 MB |
| External Photos | External Photos | 2007-09-27 | PDF 1.6 MB |
| Label Information | ID Label/Location Info | 2007-09-27 | PDF 1.3 MB |
| Block Diagram | Block Diagram | 2007-09-27 | PDF 45.5 KB |
| Operational Description | Operational Description | 2007-09-27 | PDF 176.5 KB |
| Test Photos | Test Setup Photos | 2007-09-27 | PDF 54.7 KB |
| Test Report Revised | Test Report | 2007-09-27 | PDF 739.8 KB |
| Authorization Letter | Cover Letter(s) | 2007-09-27 | PDF 8.5 KB |
| Comments | Cover Letter(s) | 2007-09-27 | PDF 45.3 KB |
| Confidentiality Letter | Cover Letter(s) | 2007-09-27 | PDF 9.5 KB |
| Response | Cover Letter(s) | 2007-09-27 | PDF 6.3 KB |
| RF Exposure Info | RF Exposure Info | 2007-09-27 | PDF 6.2 KB |
Application Information
| Application ID | ow5mkr/3fZPwl7wD39OE7g== |
|---|---|
| Final Action Date | 2007-09-27 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0016722662 |
| Model | CENTRON |
| Frequency Range | 916.3 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Electric Meter with Transceiver |
| Responsible Party | Shai Ben Avi, Project manager, sbenavi@aradtec.com |
| Technical Contact | Alex Usoskin, Hermon Laboratories, mail@hermonlabs.com |
| Non-Technical Contact | Shai Ben Avi, Arad Technologies Ltd., sbenavi@aradtec.com |
| Test Firm | Alexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com |
| TCB Email | hotline@AmericanTCB.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is Conducted calculated from Radiated measurements. This device must transmit with a source-based time-averaging duty factor not exceeding 0.12%. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ow5mkr/3fZPwl7wD39OE7g== | 2007-09-27 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 916.3 MHz | 0.0126000 | 15C |
Grants
TCB Grant - Application ow5mkr/3fZPwl7wD39OE7g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 09/27/2007 Application Dated: 09/26/2007 |
| Arad Technologies Ltd. |
| 2 carmel street |
| P.O. Box 537, |
| Yokneam Elit, 20692 Israel |
| Attention: Shai Ben Avi , Project manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VIDCENTRON |
| Name of Grantee: | Arad Technologies Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Electric Meter with Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 916.3 - 916.3 | 0.0126 |
| Power Output listed is Conducted calculated from Radiated measurements. This device must transmit with a source-based time-averaging duty factor not exceeding 0.12%. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application ow5mkr/3fZPwl7wD39OE7g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Arad Technologies Ltd. 2 carmel street P.O. Box 537, Yokneam Elit, 20692 Israel |
Date of Grant: 09/27/2007 Application Dated: 09/26/2007 |
| Attention: Shai Ben Avi , Project manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VIDCENTRON |
| Name of Grantee: | Arad Technologies Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Electric Meter with Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 916.3 - 916.3 | 0.0126 |
| Power Output listed is Conducted calculated from Radiated measurements. This device must transmit with a source-based time-averaging duty factor not exceeding 0.12%. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |