FCC ID VJA-ME3-09

Long Range Mobile Broadband Communications Device

by Rajant Corporation

Grantee Code: VJA   Product Code: ME309
Latest application date: 2010-04-26

FCC ID Device Details

FCC IDVJA-ME3-09
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVJA
Product CodeME309
Applicant BusinessRajant Corporation 🇺🇸
Related Domains rajant.com
Equipment ClassLong Range Mobile Broadband Communications Device
Test FirmMET Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
912-917 MHzOriginal Equipment2010-04-26

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2010-10-23PDF 509.2 KB
Internal Photos - ME3-09Internal Photos2010-10-23PDF 282.2 KB
Internal Photos - XR9Internal Photos2010-10-23PDF 453 KB
External PhotosExternal Photos2010-10-23PDF 270 KB
Label and LocationID Label/Location Info2010-04-26PDF 65.6 KB
Test Setup PhotosTest Setup Photos2010-10-23PDF 247.2 KB
Test Report - ME3-09Test Report2010-04-26PDF 537.1 KB
Test Report - XR9Test Report2010-04-26PDF 1.1 MB
Confidentiality Request LetterCover Letter(s)2010-04-26PDF 28.6 KB
Short Term Confidentiality Request LetterCover Letter(s)2010-04-26PDF 28.8 KB
Antenna InformationRF Exposure Info2010-04-26PDF 342.3 KB
MPE CalculationRF Exposure Info2010-04-26PDF 15.6 KB

Application Information

Application IDxgh/u30ciE/ZE5O/3DGk3Q==
Final Action Date2010-04-26
Application PurposeOriginal Equipment
Applicant FRN0016765612
Model-ME3-09
Frequency Range912-917 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionLong Range Mobile Broadband Communications Device
Responsible PartyDavid Schena, VP Finance, dschena@rajant.com , 484-595-0233
Technical ContactKeith Sullivan, Rajant Corporation, ksullivan@rajant.com , 484-595-0233
Non-Technical ContactDavid Schena, Rajant Corporation, dschena@rajant.com , 484-595-0233
Test FirmJon Fuhrman, MET Laboratories, Inc., jfuhrman@metlabs.com , 4109491880
TCB Emailtcbinfo@metlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date10/23/2010
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
xgh/u30ciE/ZE5O/3DGk3Q==2010-04-26Original Equipment

Equipment Authorization

FrequencyOutputRules
912-917 MHz0.594000015C

Grants

TCB Grant - Application xgh/u30ciE/ZE5O/3DGk3Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MET Laboratories, Inc.
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 04/26/2010

Application Dated: 04/26/2010
Rajant Corporation
400 East King Street
Malvern, PA 19355-3258
 
Attention: David Schena , VP Finance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VJA-ME3-09
Name of Grantee:  Rajant Corporation
Equipment Class: Digital Transmission System
Notes: Long Range Mobile Broadband Communications Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 912.0  -  917.0 0.594  

Power Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application xgh/u30ciE/ZE5O/3DGk3Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Rajant Corporation
400 East King Street P.O. Box ,
Malvern, PA 19355-3258
United States
  Date of Grant: 04/26/2010

Application Dated: 04/26/2010
 
Attention: David Schena , VP Finance

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VJA-ME3-09
Name of Grantee:  Rajant Corporation
Equipment Class: Digital Transmission System
Notes: Long Range Mobile Broadband Communications Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 912.0  -  917.0 0.594  

Power Output listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: