FCC ID VLUPR100
Pocket reader scanner PR100
by Advanced ID Asia Engineering Co. Ltd
Grantee Code: VLU Product Code: PR100
Latest application date: 2008-05-19
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 905.685-916.785 MHz | Original Equipment | 2008-05-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| users manual | Users Manual | 2008-07-03 | PDF 247.7 KB |
| Internal photos | Internal Photos | 2008-07-03 | PDF 199.1 KB |
| External photos | External Photos | 2008-07-03 | PDF 323 KB |
| label location and sample | ID Label/Location Info | 2008-05-19 | PDF 181.7 KB |
| Test setup photos | Test Setup Photos | 2008-07-03 | PDF 339.4 KB |
| Occupied BW plot | Test Report | 2008-05-19 | PDF 787.8 KB |
| Test report | Test Report | 2008-05-19 | PDF 267.3 KB |
| Confidentiality request | Cover Letter(s) | 2008-05-19 | PDF 83.5 KB |
| LoA | Cover Letter(s) | 2008-05-19 | PDF 47 KB |
| MPE calculation | RF Exposure Info | 2008-05-19 | PDF 56 KB |
Application Information
| Application ID | fdbNuJYns31smyrElXqu4A== |
|---|---|
| Final Action Date | 2008-05-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0016853533 |
| Model | PR100 |
| Frequency Range | 905.685-916.785 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Pocket reader scanner PR100 |
| Responsible Party | Gottfried Auer, gottfried@aae.co.th |
| Agent | Ralf Ralf Ralf, m.dudde hochfrequenz-technik, m.duddelabor@dudde.com |
| Technical Contact | Ralf Trepper, m.dudde hochfrequenz-technik, m.duddelabor@dudde.com |
| Test Firm | Manfred Dudde, m. dudde hochfrequenz-technik, manfred.dudde@t-online.de |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/03/2008 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is radiated. This is a portable device. The device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| fdbNuJYns31smyrElXqu4A== | 2008-05-19 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 905.685-916.785 MHz | 0.0900000 | 15C |
Grants
TCB Grant - Application fdbNuJYns31smyrElXqu4A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Edisonstraat 12a Zevenaar, NL-6902 PK Netherlands |
Date of Grant: 05/19/2008 Application Dated: 05/19/2008 |
| Advanced ID Asia Engineering Co. Ltd |
| 65/12 Moo10 T. Sankumpang, A. Sankumpang |
| Chiang Mai, 501030 Thailand |
| Attention: Gottfried Auer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VLUPR100 |
| Name of Grantee: | Advanced ID Asia Engineering Co. Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Pocket reader scanner PR100 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 905.685 - 916.785 | 0.09 |
| Power output listed is radiated. This is a portable device. The device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application fdbNuJYns31smyrElXqu4A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Advanced ID Asia Engineering Co. Ltd 65/12 Moo10 T. Sankumpang, A. Sankumpang P.O. Box , Chiang Mai, 501030 Thailand |
Date of Grant: 05/19/2008 Application Dated: 05/19/2008 |
| Attention: Gottfried Auer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VLUPR100 |
| Name of Grantee: | Advanced ID Asia Engineering Co. Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Pocket reader scanner PR100 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 905.685 - 916.785 | 0.09 |
| Power output listed is radiated. This is a portable device. The device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |