FCC ID VO9UU18

Blood Coagulation Meter

by Roche Diagnostics GmbH

Grantee Code: VO9   Product Code: UU18
Latest application date: 2015-11-23

FCC ID Device Details

FCC IDVO9UU18
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVO9
Product CodeUU18
Applicant BusinessRoche Diagnostics GmbH 🇩🇪
Related Domains roche.com
Equipment ClassBlood Coagulation Meter
Test FirmCTC advanced GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2015-11-23
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2015-11-06
2412-2462 MHzClass II permissive change or modification of presently authorized equipment2013-12-16
2412-2462 MHzOriginal Equipment2013-12-12

Exhibits

DocumentTypeAvailableFile
UserManual_EN.pdfUsers Manual2016-04-29PDF 5.3 MB
UserManual.pdfUsers Manual2016-03-01PDF 4.9 MB
UserManual_FR.pdfUsers Manual2016-03-01PDF 4.9 MB
UserManual.pdfUsers Manual2013-12-16PDF 5.5 MB
InstallationInstructions.pdfUsers Manual2013-12-12PDF 99.6 KB
UserManual.pdfUsers Manual2013-12-12PDF 132.9 KB
InternalPhotos.pdfInternal Photos2016-04-29PDF 1.4 MB
InternalPhotos.pdfInternal Photos2016-03-01PDF 1.4 MB
InternalPhotos.pdfInternal Photos2013-12-16PDF 375.5 KB
InternalPhotos.pdfInternal Photos2013-12-12PDF 189.2 KB
ExternalPhotos.pdfExternal Photos2016-04-29PDF 748.9 KB
ExternalPhotos.pdfExternal Photos2016-03-01PDF 478.4 KB
ExternalPhotos.pdfExternal Photos2013-12-16PDF 208.6 KB
ExternalPhotos.pdfExternal Photos2013-12-12PDF 189.2 KB
Label.pdfID Label/Location Info2015-11-23PDF 1.4 MB
Label.pdfID Label/Location Info2015-11-06PDF 1.5 MB
Label.pdfID Label/Location Info2013-12-16PDF 1.3 MB
Label_HBM4.pdfID Label/Location Info2013-12-12PDF 141.2 KB
RFExposure_Photos.pdfTest Setup Photos2016-04-29PDF 842.8 KB
TestSetupPhotos_Photos.pdf Metadata onlyTest Setup Photos2016-04-29PDF 1.3 MB
TestSetupPhotos_1-5863_13-02-06-C_Photos.pdfTest Setup Photos2016-03-01PDF 1.3 MB
TestSetupPhotos.pdfTest Setup Photos2013-12-12PDF 741.2 KB
RFExposure.pdfRF Exposure Info2013-12-16PDF 1.3 MB
TestReport.pdfTest Report2013-12-12PDF 2.8 MB
Authorization.pdfCover Letter(s)2015-11-23PDF 60 KB
ConfidentialityRequestLetter.pdfCover Letter(s)2015-11-23PDF 193.7 KB
CoverLetter DeclarationOnTestData.pdfCover Letter(s)2015-11-23PDF 93.6 KB
CoverLetter PermissiveChangeRequest.pdfCover Letter(s)2015-11-23PDF 172.9 KB
CoverLetter TemporaryConfRequest.pdfCover Letter(s)2015-11-23PDF 180.8 KB
CoverLetter Authorization.pdfCover Letter(s)2015-11-06PDF 60.9 KB
CoverLetter ConfidentialityRequestLetter.pdfCover Letter(s)2015-11-06PDF 193.7 KB
CoverLetter PermissiveChangeRequest.pdfCover Letter(s)2015-11-06PDF 172.5 KB
CoverLetter ShortTermConf.pdfCover Letter(s)2015-11-06PDF 179.7 KB
PCIIRequestLetter.pdfCover Letter(s)2013-12-16PDF 100.2 KB
ModularApprovalRequestLetter.pdfCover Letter(s)2013-12-12PDF 248.8 KB
RFExposure-A_Caldata.pdfRF Exposure Info2015-11-23PDF 1.8 MB
RFExposure.pdfRF Exposure Info2015-11-23PDF 905.4 KB
RFExposure-A_Caldata.pdfRF Exposure Info2015-11-06PDF 3.5 MB
RFExposure_Caldata.pdf Metadata onlyRF Exposure Info2015-11-06PDF 1.8 MB
RFExposure-A_Caldata.pdfRF Exposure Info2013-12-16PDF 838 KB
BlockDiagram.pdf Metadata onlyBlock DiagramPDF 175.7 KB
BlockDiagram.pdf Metadata onlyBlock DiagramPDF 175.7 KB
Schematics.pdf Metadata onlySchematicsPDF 583.3 KB
OperationalDescription-2.pdf Metadata onlyOperational DescriptionPDF 24.4 KB
OperationalDescription.pdf Metadata onlyOperational DescriptionPDF 29.5 KB

Application Information

Application IDakZuAdDkAoZwQpG4dodrmA==
Final Action Date2015-11-23
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0016954943
ModelUU18
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionBlood Coagulation Meter
Responsible PartyChristian Paulus, christian.paulus@roche.com , +49621759
Test FirmGerald Schmidt, CTC advanced GmbH, mail@ctcadvanced.com , 49-681-598-0
TCB EmailOliver.Kneip@cetecom.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/01/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPCII to allow portable host devices Limited Modular Approval. Power Output listed is conducted. This Module is approved for installation in devices under direct control of the Grantee The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.16 W/kg.

Applications

Application IDDatePurpose
akZuAdDkAoZwQpG4dodrmA==2015-11-23Class II permissive change or modification of presently authorized equipment
o7Y0y08qHIS7PjhtX86Rfg==2015-11-06Class II permissive change or modification of presently authorized equipment
BA/N+tzJf2dkiBR/K0SocQ==2013-12-16Class II permissive change or modification of presently authorized equipment
q7lzWifMqnMyD/8X+RzUMA==2013-12-12Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.059000015C

Grants

TCB Grant - Application q7lzWifMqnMyD/8X+RzUMA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 12/12/2013

Application Dated: 12/12/2013
Roche Diagnostics GmbH
Sandhofer Strasse 116
Mannheim, 68305
Germany
 
Attention: Alexander Ruegner , Dr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: HBM 4
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee.

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.


EAS Grant - Application q7lzWifMqnMyD/8X+RzUMA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Roche Diagnostics GmbH
Sandhofer Strasse 116 P.O. Box ,
Mannheim, 68305
Germany
  Date of Grant: 12/12/2013

Application Dated: 12/12/2013
 
Attention: Alexander Ruegner , Dr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: HBM 4
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee.

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



TCB Grant - Application o7Y0y08qHIS7PjhtX86Rfg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 11/06/2015

Application Dated: 11/05/2015
Roche Diagnostics GmbH
Sandhofer Strasse 116
Mannheim, 68305
Germany
 
Attention: Christian Paulus

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: Medical Device with WLAN b/g
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

PCII to allow portable host devices Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.16 W/kg.


EAS Grant - Application o7Y0y08qHIS7PjhtX86Rfg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Roche Diagnostics GmbH
Sandhofer Strasse 116
Mannheim, 68305
Germany
  Date of Grant: 11/06/2015

Application Dated: 11/05/2015
 
Attention: Christian Paulus

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: Medical Device with WLAN b/g
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

PCII to allow portable host devices Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.16 W/kg.



TCB Grant - Application BA/N+tzJf2dkiBR/K0SocQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM ICT Services GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 12/16/2013

Application Dated: 12/16/2013
Roche Diagnostics GmbH
Sandhofer Strasse 116
Mannheim, 68305
Germany
 
Attention: Alexander Ruegner , Dr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: HBM4
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

PCII to allow portable host devices Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.10 W/kg.


EAS Grant - Application BA/N+tzJf2dkiBR/K0SocQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Roche Diagnostics GmbH
Sandhofer Strasse 116 P.O. Box ,
Mannheim, 68305
Germany
  Date of Grant: 12/16/2013

Application Dated: 12/16/2013
 
Attention: Alexander Ruegner , Dr

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: HBM4
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

PCII to allow portable host devices Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.10 W/kg.



TCB Grant - Application akZuAdDkAoZwQpG4dodrmA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CTC advanced GmbH
Untertuerkheimer Strasse 6-10
66117 Saarbruecken,
Germany
Date of Grant: 11/23/2015

Application Dated: 11/23/2015
Roche Diagnostics GmbH
Sandhofer Strasse 116
Mannheim, 68305
Germany
 
Attention: Christian Paulus

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: Blood Coagulation Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

PCII to allow portable host devices Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.16 W/kg.


EAS Grant - Application akZuAdDkAoZwQpG4dodrmA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Roche Diagnostics GmbH
Sandhofer Strasse 116
Mannheim, 68305
Germany
  Date of Grant: 11/23/2015

Application Dated: 11/23/2015
 
Attention: Christian Paulus

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VO9UU18
Name of Grantee:  Roche Diagnostics GmbH
Equipment Class: Digital Transmission System
Notes: Blood Coagulation Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.059  

PCII to allow portable host devices Limited Modular Approval.

Power Output listed is conducted.

This Module is approved for installation in devices under direct control of the Grantee

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The highest reported SAR is 0.16 W/kg.



Mail To: