FCC ID VQK-FOMA-F905IBIZ

PCS Licensed Transmitter

by Fujitsu Limited

Grantee Code: VQK   Product Code: FOMAF905IBIZ
Latest application date: 2007-12-13

FCC ID Device Details

FCC IDVQK-FOMA-F905IBIZ
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVQK
Product CodeFOMAF905IBIZ
Applicant BusinessFujitsu Limited 🇯🇵
Related Domains jp.fujitsu.com rft.jp
Equipment ClassPCS Licensed Transmitter
Test FirmRF Technologies Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2007-12-13

Exhibits

DocumentTypeAvailableFile
Users manual part 1Users Manual2008-02-13PDF 1,013.8 KB
Users manual part 2Users Manual2008-02-13PDF 2.6 MB
Users manual part 3Users Manual2008-02-13PDF 2.8 MB
Internal photosInternal Photos2008-02-13PDF 423.1 KB
External photosExternal Photos2008-02-13PDF 383.9 KB
LabelID Label/Location Info2007-12-13PDF 262.3 KB
Label locationID Label/Location Info2007-12-13PDF 132 KB
Test setup photos SAR reportTest Setup Photos2008-02-13PDF 366.7 KB
Test setup photos part 24 reportTest Setup Photos2008-02-13PDF 127.8 KB
Test reportTest Report2007-12-13PDF 1.7 MB
Confidentiality request long termCover Letter(s)2007-12-13PDF 36.6 KB
Confidentiality request short termCover Letter(s)2007-12-13PDF 321.6 KB
Disable FM transmitterCover Letter(s)2007-12-13PDF 261.4 KB
Disable GSM and WCDMACover Letter(s)2007-12-13PDF 306.4 KB
DoACover Letter(s)2007-12-13PDF 138.4 KB
SAR dipole calibrationRF Exposure Info2007-12-13PDF 889.8 KB
SAR probe calibrationRF Exposure Info2007-12-13PDF 848.6 KB
SAR reportRF Exposure Info2007-12-13PDF 298.5 KB
SAR system validationRF Exposure Info2007-12-13PDF 83.2 KB
SAR test plotsRF Exposure Info2007-12-13PDF 324.4 KB

Application Information

Application IDRi8ovwrhQ3aq82jHdjgE/A==
Final Action Date2007-12-13
Application PurposeOriginal Equipment
Applicant FRN0016383648
Model-FOMA-F905IBIZ
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionPCS Licensed Transmitter
Responsible PartyYoshihiko Taki, Senior Engineer, yoshihiko.taki@jp.fujitsu.com , +81447543746
Technical ContactToshihiro Ikegami, RF Technologies Ltd., ikegami@rft.jp , +81-45-534-0645
Non-Technical ContactKoichi Kabata, RF Technologies Ltd., kabata@rft.jp , +81-45-534-0645
Test FirmToshihiro Ikegami, RF Technologies Co., Ltd., ikegami@rft.jp , 81455340645
TCB Emailcertification@telefication.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Short-Term Confidentiality Date02/13/2008
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. This filing is only applicable for 1900 MHz operations. This device contains FM, GSM and WCDMA functions that are not operational in U.S. territories. SAR compliance for body-worn operation is based on a separation distance of 1.5 cm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. The highest reported SAR values are: Head: 0.278 mW/g; Body-worn: 0.373 mW/g.

Applications

Application IDDatePurpose
Ri8ovwrhQ3aq82jHdjgE/A==2007-12-13Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz0.851000043.0000000000Hz314KGXW24E

Grants

TCB Grant - Application Ri8ovwrhQ3aq82jHdjgE/A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 12/13/2007

Application Dated: 12/13/2007
Fujitsu Limited
1-1 Kamikodanaka 4-chome
Nakahara-ku
Kawasaki, 2118588
Japan
 
Attention: Yoshihiko Taki , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VQK-FOMA-F905IBIZ
Name of Grantee:  Fujitsu Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: PCS Licensed Transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.851 43.0  Hz 314KGXW

Power output listed is conducted. This filing is only applicable for 1900 MHz operations. This device contains FM, GSM and WCDMA functions that are not operational in U.S. territories.

SAR compliance for body-worn operation is based on a separation distance of 1.5 cm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. The highest reported SAR values are: Head: 0.278 mW/g; Body-worn: 0.373 mW/g.


EAS Grant - Application Ri8ovwrhQ3aq82jHdjgE/A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Fujitsu Limited
1-1 Kamikodanaka 4-chome Nakahara-kuP.O. Box ,
Kawasaki, 2118588
Japan
  Date of Grant: 12/13/2007

Application Dated: 12/13/2007
 
Attention: Yoshihiko Taki , Senior Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VQK-FOMA-F905IBIZ
Name of Grantee:  Fujitsu Limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: PCS Licensed Transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 0.851 43.0  Hz 314KGXW

Power output listed is conducted. This filing is only applicable for 1900 MHz operations. This device contains FM, GSM and WCDMA functions that are not operational in U.S. territories.

SAR compliance for body-worn operation is based on a separation distance of 1.5 cm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not listed in this filing may not contain metallic components. The highest reported SAR values are: Head: 0.278 mW/g; Body-worn: 0.373 mW/g.



Mail To: