FCC ID VRQ-GT-200

3G GPS Tracker

by NaviSys Technology Corp.

Grantee Code: VRQ   Product Code: GT200
Latest application date: 2016-06-17

Device Images

FCC ID Device Details

FCC IDVRQ-GT-200
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVRQ
Product CodeGT200
Applicant BusinessNaviSys Technology Corp. 🇹🇼
Related Domains navisys.com.tw
Equipment Class3G GPS Tracker
Test FirmBTL Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
826.4-846.6 MHzOriginal Equipment2016-06-17

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2016-06-17PDF 790.6 KB
Internal PhotosInternal Photos2016-06-17PDF 2.9 MB
External PhotosExternal Photos2016-06-17PDF 1 MB
FCC ID Label and label locationID Label/Location Info2016-06-17PDF 1 MB
Test Setup Photos_PCBTest Setup Photos2016-06-17PDF 438.8 KB
Test Report_part 22Test Report2016-06-17PDF 1.4 MB
Test Report_part 24Test Report2016-06-17PDF 1.4 MB
POACover Letter(s)2016-06-17PDF 27.2 KB
Request for non-disclosureCover Letter(s)2016-06-17PDF 29.5 KB
SAR Report-1RF Exposure Info2016-06-17PDF 935.5 KB
SAR Report-2RF Exposure Info2016-06-17PDF 604.5 KB
SAR Report-3RF Exposure Info2016-06-17PDF 519.4 KB
SAR Report-4RF Exposure Info2016-06-17PDF 805.9 KB
Block Diagrams Metadata onlyBlock DiagramPDF 78.7 KB
Schematics Metadata onlySchematicsPDF 336 KB
Schematics_module Metadata onlySchematicsPDF 467.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 416.2 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 65.5 KB
Parts List_module Metadata onlyParts List/Tune Up InfoPDF 50.4 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 75.1 KB

Application Information

Application IDRs/LCWwiAA8DJ3SbXhZpTQ==
Final Action Date2016-06-17
Application PurposeOriginal Equipment
Applicant FRN0017056557
ModelGT-200
Frequency Range826.4-846.6 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device Description3G GPS Tracker
Responsible PartyChun-Tsai Pan, Manager, ctpan@navisys.com.tw , 886-3-5632598
Test FirmAndy Chiu, BTL Inc., andy@neutron.com.tw , 886-2-2657-3299
TCB Emailbentje.holger@phoenix-testlab.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.77 W/kg; Body-worn: 0.66 W/kg.

Applications

Application IDDatePurpose
Rs/LCWwiAA8DJ3SbXhZpTQ==2016-06-17Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
826.4-846.6 MHz0.1282.5ppm4M17F9W22H
1852.4-1907.6 MHz0.1512.5ppm4M17F9W24E

Grants

TCB Grant - Application Rs/LCWwiAA8DJ3SbXhZpTQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 06/17/2016

Application Dated: 06/17/2016
NaviSys Technology Corp.
2F, No.56, Park Ave.II, Science-Based
Industrial Park
Hsinchu, 30844
Taiwan
 
Attention: Chun-Tsai Pan , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VRQ-GT-200
Name of Grantee:  NaviSys Technology Corp.
Equipment Class: PCS Licensed Transmitter
Notes: 3G GPS Tracker
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.128 2.5  PM 4M17F9W
24E 1852.4  -  1907.6 0.151 2.5  PM 4M17F9W

Power listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.77 W/kg; Body-worn: 0.66 W/kg.

EAS Grant - Application Rs/LCWwiAA8DJ3SbXhZpTQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

NaviSys Technology Corp.
2F, No.56, Park Ave.II, Science-Based Industrial Park
Hsinchu, 30844
Taiwan
  Date of Grant: 06/17/2016

Application Dated: 06/17/2016
 
Attention: Chun-Tsai Pan , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VRQ-GT-200
Name of Grantee:  NaviSys Technology Corp.
Equipment Class: PCS Licensed Transmitter
Notes: 3G GPS Tracker
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 826.4  -  846.6 0.128 2.5  PM 4M17F9W
24E 1852.4  -  1907.6 0.151 2.5  PM 4M17F9W

Power listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.77 W/kg; Body-worn: 0.66 W/kg.