FCC ID VRSUH100I
Diagnostic Ultrasound System
by Qisda Corporation
Grantee Code: VRS Product Code: UH100I
Latest application date: 2015-10-26
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2015-10-26 |
| 2402-2480 MHz | Original Equipment | 2015-10-26 |
| 2402-2480 MHz | Original Equipment | 2015-10-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual_Part I | Users Manual | 2016-04-21 | PDF 5.2 MB |
| User manual_Part II | Users Manual | 2016-04-21 | PDF 4.5 MB |
| Internal photo | Internal Photos | 2016-04-21 | PDF 3.6 MB |
| External photo | External Photos | 2016-04-21 | PDF 1.2 MB |
| ID label/Location info | ID Label/Location Info | 2015-10-26 | PDF 25.3 KB |
| Test setup photo_BLE, WLAN UNII | Test Setup Photos | 2016-04-21 | PDF 237.4 KB |
| Test setup photo_BT | Test Setup Photos | 2016-04-21 | PDF 238.5 KB |
| Test Report_P15.247 BT3.0 | Test Report | 2015-10-26 | PDF 3.2 MB |
| Test report_P15.247 BLE | Test Report | 2015-10-26 | PDF 1.7 MB |
| Test report_P15.247 WLAN | Test Report | 2015-10-26 | PDF 4 MB |
| Test report_UNII | Test Report | 2015-10-26 | PDF 4.2 MB |
| Declaration of authorization | Cover Letter(s) | 2015-10-26 | PDF 138.7 KB |
| confidentiality | Cover Letter(s) | 2015-10-26 | PDF 75.3 KB |
| MPE | RF Exposure Info | 2015-10-26 | PDF 154.4 KB |
| MPE_BLE | RF Exposure Info | 2015-10-26 | PDF 154.3 KB |
| MPE_UNII | RF Exposure Info | 2015-10-26 | PDF 182.6 KB |
| MPE_WLAN | RF Exposure Info | 2015-10-26 | PDF 165 KB |
| Block diagram Metadata only | Block Diagram | PDF 748.5 KB | |
| Schematics_Carrier Board Metadata only | Schematics | PDF 1 MB | |
| Schematics_Intrinsyc SOM Metadata only | Schematics | PDF 1.5 MB | |
| Schematics_VivaPro_PCBA_Rev5_64CH_Board Metadata only | Schematics | PDF 1.2 MB | |
| Schematics_VivaPro_PCBA_Rev5_Backend_Board Metadata only | Schematics | PDF 732.6 KB | |
| Schematicss_Intrinsyc SOM Metadata only | Schematics | PDF 1.5 MB | |
| Operational description Metadata only | Operational Description | PDF 220.4 KB | |
| Software Security Cover Letter Metadata only | Operational Description | PDF 87.2 KB |
Application Information
| Application ID | wyjir8KZGKyp0LKw4fctEw== |
|---|---|
| Final Action Date | 2015-10-26 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0016869570 |
| Model | UH100I |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Diagnostic Ultrasound System |
| Responsible Party | Tom CK Lung, Researcher, Tom.CK.Lung@Qisda.com |
| Technical Contact | Willis Chen, SGS Taiwan Ltd., willischen@sgs.com |
| Non-Technical Contact | Willis Chen, SGS Taiwan Ltd., willischen@sgs.com |
| Test Firm | Jason Lin, SGS Taiwan Ltd., jason.lin@sgs.com |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 04/21/2016 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| wyjir8KZGKyp0LKw4fctEw== | 2015-10-26 | Original Equipment |
| LJEarEnsa1UA1msJdFnMcw== | 2015-10-26 | Original Equipment |
| +YO1+UByEu4SfDp+yh86DQ== | 2015-10-26 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application wyjir8KZGKyp0LKw4fctEw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 10/26/2015 Application Dated: 10/23/2015 |
| Qisda Corporation |
| NO.157, SHAN-YING ROAD, |
| SHAN-TING LI, GUEISHAN DIST., |
| TAOYUAN, 333 Taiwan |
| Attention: Tom Lung , Researcher |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VRSUH100I |
| Name of Grantee: | Qisda Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Diagnostic Ultrasound System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.0226 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.0136 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application wyjir8KZGKyp0LKw4fctEw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Qisda Corporation NO.157, SHAN-YING ROAD, SHAN-TING LI, GUEISHAN DIST., TAOYUAN, 333 Taiwan |
Date of Grant: 10/26/2015 Application Dated: 10/23/2015 |
| Attention: Tom Lung , Researcher |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VRSUH100I |
| Name of Grantee: | Qisda Corporation |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Diagnostic Ultrasound System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.0226 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.0136 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 10/26/2015 Application Dated: 10/23/2015 |
| Qisda Corporation |
| NO.157, SHAN-YING ROAD, |
| SHAN-TING LI, GUEISHAN DIST., |
| TAOYUAN, 333 Taiwan |
| Attention: Tom Lung , Researcher |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VRSUH100I |
| Name of Grantee: | Qisda Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Diagnostic Ultrasound System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0024 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.0938 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application LJEarEnsa1UA1msJdFnMcw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Qisda Corporation NO.157, SHAN-YING ROAD, SHAN-TING LI, GUEISHAN DIST., TAOYUAN, 333 Taiwan |
Date of Grant: 10/26/2015 Application Dated: 10/23/2015 |
| Attention: Tom Lung , Researcher |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VRSUH100I |
| Name of Grantee: | Qisda Corporation |
| Equipment Class: | Digital Transmission System |
| Notes: | Diagnostic Ultrasound System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0024 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.0938 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Wilmersdorf 50 Apeldoorn, NL-7300 AC Netherlands |
Date of Grant: 10/26/2015 Application Dated: 10/23/2015 |
| Qisda Corporation |
| NO.157, SHAN-YING ROAD, |
| SHAN-TING LI, GUEISHAN DIST., |
| TAOYUAN, 333 Taiwan |
| Attention: Tom Lung , Researcher |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VRSUH100I |
| Name of Grantee: | Qisda Corporation |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Diagnostic Ultrasound System |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0067 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application +YO1+UByEu4SfDp+yh86DQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Qisda Corporation NO.157, SHAN-YING ROAD, SHAN-TING LI, GUEISHAN DIST., TAOYUAN, 333 Taiwan |
Date of Grant: 10/26/2015 Application Dated: 10/23/2015 |
| Attention: Tom Lung , Researcher |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VRSUH100I |
| Name of Grantee: | Qisda Corporation |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Diagnostic Ultrasound System |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0067 |
| Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |