FCC ID VUVMPE25KVZW
Cellular/PCS Indoor Repeater
by Cellvine Ltd.
Grantee Code: VUV Product Code: MPE25KVZW
Latest application date: 2008-09-19
FCC ID Device Details
| FCC ID | VUVMPE25KVZW |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | VUV |
| Product Code | MPE25KVZW |
| Applicant Business | Cellvine Ltd. 🇮🇱 |
| Related Domains | |
| Equipment Class | Cellular/PCS Indoor Repeater |
| Test Firm | MET Laboratories, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824-849 MHz | Original Equipment | 2008-09-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Internal Photos | Internal Photos | 2008-09-19 | PDF 3 MB |
| External Photos | External Photos | 2008-09-19 | PDF 189.1 KB |
| Label and Location | ID Label/Location Info | 2008-09-19 | PDF 92 KB |
| Test Setup Photos | Test Setup Photos | 2008-09-19 | PDF 363.8 KB |
| Test Report | Test Report | 2008-09-19 | PDF 2.8 MB |
| Confidentiality Request | Cover Letter(s) | 2008-09-19 | PDF 30.1 KB |
| Antenna Data Information | RF Exposure Info | 2008-09-19 | PDF 408 KB |
| MPE Calculations | RF Exposure Info | 2008-09-19 | PDF 30.5 KB |
Application Information
| Application ID | FJQPZFdcspBtrJK6OxZ1UA== |
|---|---|
| Final Action Date | 2008-09-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0017172503 |
| Model | MPE25KVZW |
| Frequency Range | 824-849 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Cellular/PCS Indoor Repeater |
| Responsible Party | Richard Parker, Technical Mktg Director, richard@cellvine.com |
| Technical Contact | Ziv Shani, Cellvine LTD., ziv@cellvine.com |
| Test Firm | John Mason, MET Laboratories, Inc., jmason@metlabs.com |
| TCB Email | tcbinfo@metlabs.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted and is composite or maximum for single channel operation. This is a multi-carrier repeater for CDMA 2000 modulations. For multi-carrier operation, the power per carrier decreases proportionally as the number of carriers is increased. The antenna(s) used for this transmitter must be professionally installed. This application is being granted with a maximum 6 dBi donor antenna. A separation distance of at least 20 cm must be maintained between antennas and any persons. Coverage antennas greater than 7 dBi may require RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| FJQPZFdcspBtrJK6OxZ1UA== | 2008-09-19 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application FJQPZFdcspBtrJK6OxZ1UA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MET Laboratories, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230-3432 |
Date of Grant: 09/19/2008 Application Dated: 09/19/2008 |
| Cellvine Ltd. |
| 6 Yoni Netanyahu St. |
| Or Yehuda, 60376 Israel |
| Attention: Richard Parker , Technical Mktg Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VUVMPE25KVZW |
| Name of Grantee: | Cellvine Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Cellular/PCS Indoor Repeater |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.0 - 849.0 | 0.019 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.159 | Amp | F9W | |
| 24E | 1850.0 - 1910.0 | 0.021 | Amp | F9W | |
| 24E | 1930.0 - 1990.0 | 0.176 | Amp | F9W |
| Power output listed is conducted and is composite or maximum for single channel operation. This is a multi-carrier repeater for CDMA 2000 modulations. For multi-carrier operation, the power per carrier decreases proportionally as the number of carriers is increased. The antenna(s) used for this transmitter must be professionally installed. This application is being granted with a maximum 6 dBi donor antenna. A separation distance of at least 20 cm must be maintained between antennas and any persons. Coverage antennas greater than 7 dBi may require RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
EAS Grant - Application FJQPZFdcspBtrJK6OxZ1UA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Cellvine Ltd. 6 Yoni Netanyahu St. P.O. Box , Or Yehuda, 60376 Israel |
Date of Grant: 09/19/2008 Application Dated: 09/19/2008 |
| Attention: Richard Parker , Technical Mktg Director |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | VUVMPE25KVZW |
| Name of Grantee: | Cellvine Ltd. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Cellular/PCS Indoor Repeater |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.0 - 849.0 | 0.019 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.159 | Amp | F9W | |
| 24E | 1850.0 - 1910.0 | 0.021 | Amp | F9W | |
| 24E | 1930.0 - 1990.0 | 0.176 | Amp | F9W |
| Power output listed is conducted and is composite or maximum for single channel operation. This is a multi-carrier repeater for CDMA 2000 modulations. For multi-carrier operation, the power per carrier decreases proportionally as the number of carriers is increased. The antenna(s) used for this transmitter must be professionally installed. This application is being granted with a maximum 6 dBi donor antenna. A separation distance of at least 20 cm must be maintained between antennas and any persons. Coverage antennas greater than 7 dBi may require RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |