FCC ID VUVMPE25KVZW

Cellular/PCS Indoor Repeater

by Cellvine Ltd.

Grantee Code: VUV   Product Code: MPE25KVZW
Latest application date: 2008-09-19

FCC ID Device Details

FCC IDVUVMPE25KVZW
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVUV
Product CodeMPE25KVZW
Applicant BusinessCellvine Ltd. 🇮🇱
Related Domains cellvine.com
Equipment ClassCellular/PCS Indoor Repeater
Test FirmMET Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824-849 MHzOriginal Equipment2008-09-19

Exhibits

DocumentTypeAvailableFile
Internal PhotosInternal Photos2008-09-19PDF 3 MB
External PhotosExternal Photos2008-09-19PDF 189.1 KB
Label and LocationID Label/Location Info2008-09-19PDF 92 KB
Test Setup PhotosTest Setup Photos2008-09-19PDF 363.8 KB
Test ReportTest Report2008-09-19PDF 2.8 MB
Confidentiality RequestCover Letter(s)2008-09-19PDF 30.1 KB
Antenna Data InformationRF Exposure Info2008-09-19PDF 408 KB
MPE CalculationsRF Exposure Info2008-09-19PDF 30.5 KB

Application Information

Application IDFJQPZFdcspBtrJK6OxZ1UA==
Final Action Date2008-09-19
Application PurposeOriginal Equipment
Applicant FRN0017172503
ModelMPE25KVZW
Frequency Range824-849 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionCellular/PCS Indoor Repeater
Responsible PartyRichard Parker, Technical Mktg Director, richard@cellvine.com , 1-404-478-7201
Technical ContactZiv Shani, Cellvine LTD., ziv@cellvine.com , +972-3-6348881
Test FirmJohn Mason, MET Laboratories, Inc., jmason@metlabs.com , 410-354-3300
TCB Emailtcbinfo@metlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted and is composite or maximum for single channel operation. This is a multi-carrier repeater for CDMA 2000 modulations. For multi-carrier operation, the power per carrier decreases proportionally as the number of carriers is increased. The antenna(s) used for this transmitter must be professionally installed. This application is being granted with a maximum 6 dBi donor antenna. A separation distance of at least 20 cm must be maintained between antennas and any persons. Coverage antennas greater than 7 dBi may require RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
FJQPZFdcspBtrJK6OxZ1UA==2008-09-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824-849 MHz0.019AmpF9W22H
869-894 MHz0.159AmpF9W22H
1850-1910 MHz0.021AmpF9W24E
1930-1990 MHz0.176AmpF9W24E

Grants

TCB Grant - Application FJQPZFdcspBtrJK6OxZ1UA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MET Laboratories, Inc.
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 09/19/2008

Application Dated: 09/19/2008
Cellvine Ltd.
6 Yoni Netanyahu St.
Or Yehuda, 60376
Israel
 
Attention: Richard Parker , Technical Mktg Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VUVMPE25KVZW
Name of Grantee:  Cellvine Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Cellular/PCS Indoor Repeater
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.0  -  849.0 0.019  Amp F9W
22H 869.0  -  894.0 0.159  Amp F9W
24E 1850.0  -  1910.0 0.021  Amp F9W
24E 1930.0  -  1990.0 0.176  Amp F9W

Power output listed is conducted and is composite or maximum for single channel operation. This is a multi-carrier repeater for CDMA 2000 modulations. For multi-carrier operation, the power per carrier decreases proportionally as the number of carriers is increased. The antenna(s) used for this transmitter must be professionally installed. This application is being granted with a maximum 6 dBi donor antenna. A separation distance of at least 20 cm must be maintained between antennas and any persons. Coverage antennas greater than 7 dBi may require RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application FJQPZFdcspBtrJK6OxZ1UA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cellvine Ltd.
6 Yoni Netanyahu St. P.O. Box ,
Or Yehuda, 60376
Israel
  Date of Grant: 09/19/2008

Application Dated: 09/19/2008
 
Attention: Richard Parker , Technical Mktg Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VUVMPE25KVZW
Name of Grantee:  Cellvine Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Cellular/PCS Indoor Repeater
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.0  -  849.0 0.019  Amp F9W
22H 869.0  -  894.0 0.159  Amp F9W
24E 1850.0  -  1910.0 0.021  Amp F9W
24E 1930.0  -  1990.0 0.176  Amp F9W

Power output listed is conducted and is composite or maximum for single channel operation. This is a multi-carrier repeater for CDMA 2000 modulations. For multi-carrier operation, the power per carrier decreases proportionally as the number of carriers is increased. The antenna(s) used for this transmitter must be professionally installed. This application is being granted with a maximum 6 dBi donor antenna. A separation distance of at least 20 cm must be maintained between antennas and any persons. Coverage antennas greater than 7 dBi may require RF exposure compliance to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



Mail To: