FCC ID VZUMC55I

Quadband GSM/GPRS Module

by Aerotel Medical Systems Ltd.

Grantee Code: VZU   Product Code: MC55I
Latest application date: 2010-08-27

FCC ID Device Details

FCC IDVZUMC55I
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeVZU
Product CodeMC55I
Applicant BusinessAerotel Medical Systems Ltd. 🇮🇱
Related Domains aerotel.com
Equipment ClassQuadband GSM/GPRS Module

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzClass II permissive change or modification of presently authorized equipment2010-08-27
824.2-848.8 MHzChange in identification of presently authorized equipment. Original FCC ID: QIPMC55I Grant Date: 01/23/20082010-08-20

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2010-08-20PDF 340.4 KB
Label and LocationID Label/Location Info2010-08-20PDF 62.5 KB
POACover Letter(s)2010-08-27PDF 71.6 KB
Reason for PCCover Letter(s)2010-08-27PDF 72 KB
Authorization LetterCover Letter(s)2010-08-20PDF 71.6 KB
Change in ID LetterCover Letter(s)2010-08-20PDF 367.3 KB
Cover LetterCover Letter(s)2010-08-20PDF 98.5 KB
RF exposure MPERF Exposure Info2010-08-27PDF 35.1 KB

Application Information

Application IDBLiNo0D+N9TjP8rTE6rYiw==
Final Action Date2010-08-27
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0017238296
ModelMC55I
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionQuadband GSM/GPRS Module
Responsible PartyItsik Ben David, R&D; Manager, itsik@aerotel.com , +972-3-5593222
TCB Emailhotline@americantcb.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is peak conducted. Licensed Modular Transmitter. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements This PC is to allow collocation with with BT transmitter FCC ID:POOWML-C40.

Applications

Application IDDatePurpose
BLiNo0D+N9TjP8rTE6rYiw==2010-08-27Class II permissive change or modification of presently authorized equipment
rKlwdo9LPTnKF70pkuv0EA==2010-08-20Change in identification of presently authorized equipment. Original FCC ID: QIPMC55I Grant Date: 01/23/2008

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz1.8070.0027ppm300KGXW22H
1850.2-1909.8 MHz1.0260.0024ppm300KGXW24E

Grants

TCB Grant - Application rKlwdo9LPTnKF70pkuv0EA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/20/2010

Application Dated: 08/19/2010
Aerotel Medical Systems Ltd.
5 Hazoref St.
Holon, 58856
Israel
 
Attention: Itsik Ben David , R&D Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VZUMC55I
Name of Grantee:  Aerotel Medical Systems Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Quadband GSM/GPRS Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.807 0.0027  PM 300KGXW
24E 1850.2  -  1909.8 1.026 0.0024  PM 300KGXW

Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance.

For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements


EAS Grant - Application rKlwdo9LPTnKF70pkuv0EA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Aerotel Medical Systems Ltd.
5 Hazoref St. P.O. Box ,
Holon, 58856
Israel
  Date of Grant: 08/20/2010

Application Dated: 08/19/2010
 
Attention: Itsik Ben David , R&D Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VZUMC55I
Name of Grantee:  Aerotel Medical Systems Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Quadband GSM/GPRS Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.807 0.0027  PM 300KGXW
24E 1850.2  -  1909.8 1.026 0.0024  PM 300KGXW

Power Output listed is peak conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance.

For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements



TCB Grant - Application BLiNo0D+N9TjP8rTE6rYiw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 08/27/2010

Application Dated: 08/27/2010
Aerotel Medical Systems Ltd.
5 Hazoref St.
Holon, 58856
Israel
 
Attention: Itsik Ben David , R&D Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VZUMC55I
Name of Grantee:  Aerotel Medical Systems Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Quadband GSM/GPRS Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.807 0.0027  PM 300KGXW
24E 1850.2  -  1909.8 1.026 0.0024  PM 300KGXW

Power Output listed is peak conducted. Licensed Modular Transmitter. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance.

For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements

This PC is to allow collocation with with BT transmitter FCC ID:POOWML-C40.


EAS Grant - Application BLiNo0D+N9TjP8rTE6rYiw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Aerotel Medical Systems Ltd.
5 Hazoref St. P.O. Box ,
Holon, 58856
Israel
  Date of Grant: 08/27/2010

Application Dated: 08/27/2010
 
Attention: Itsik Ben David , R&D Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  VZUMC55I
Name of Grantee:  Aerotel Medical Systems Ltd.
Equipment Class: PCS Licensed Transmitter
Notes: Quadband GSM/GPRS Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.807 0.0027  PM 300KGXW
24E 1850.2  -  1909.8 1.026 0.0024  PM 300KGXW

Power Output listed is peak conducted. Licensed Modular Transmitter. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

For mobile operating configurations the antenna gain, including cable loss, must not exceed 2.89 dBi at 1900 MHz and 1.33 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance.

For fixed operating configurations the final device including antenna gain and cable loss, must fulfil the requirements of 1.1307 of the rules for satisfying RF exposure compliance.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

The final product operating with this transmitter must include operating instructions and applicable warnings, as described in this filing, for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of the specific requirements

This PC is to allow collocation with with BT transmitter FCC ID:POOWML-C40.



Mail To: