FCC ID W6UERA682335R
DAS
by SOLiD, Inc.
Grantee Code: W6U Product Code: ERA682335R
Latest application date: 2022-02-16
FCC ID Device Details
| FCC ID | W6UERA682335R |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | W6U |
| Product Code | ERA682335R |
| Applicant Business | SOLiD, Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | DAS |
| Test Firm | HCT Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2350-2360 MHz | Original Equipment | 2022-02-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2022-08-15 | PDF 2 MB |
| Internal Photos | Internal Photos | 2022-08-15 | PDF 781.3 KB |
| External Photos | External Photos | 2022-08-15 | PDF 944.9 KB |
| Label Info/Location | ID Label/Location Info | 2022-02-16 | PDF 360 KB |
| Test Setup Photos | Test Setup Photos | 2022-08-15 | PDF 1,009.1 KB |
| Test Report Part 1 | Test Report | 2022-02-16 | PDF 5.1 MB |
| Test Report Part 2 | Test Report | 2022-02-16 | PDF 2.3 MB |
| Attestation Letter for Warning | Attestation Statements | 2022-02-16 | PDF 631.7 KB |
| Agent Authorization Letter | Cover Letter(s) | 2022-02-16 | PDF 373 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2022-02-16 | PDF 425.7 KB |
| RF Exposure Report | RF Exposure Info | 2022-02-16 | PDF 330 KB |
| Block Diagram Metadata only | Block Diagram | PDF 429.4 KB | |
| Schematics Metadata only | Schematics | PDF 616.3 KB | |
| Operational Description Metadata only | Operational Description | PDF 585.3 KB | |
| Part List Metadata only | Parts List/Tune Up Info | PDF 291.8 KB | |
| Tune-up Procedure Metadata only | Parts List/Tune Up Info | PDF 707.7 KB |
Application Information
| Application ID | JLtDK7b/ldkhKANe/jp3Dw== |
|---|---|
| Final Action Date | 2022-02-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018550988 |
| Model | ERA682335R |
| Frequency Range | 2350-2360 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | DAS |
| Responsible Party | Yong Chul Kim, Team Manager, yckim@solid.co.kr |
| Test Firm | Lee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr |
| TCB Email | TCB@hctamerica.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 08/15/2022 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.450 Watts on ANT1. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17dBi with minimum separation distance 60 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| JLtDK7b/ldkhKANe/jp3Dw== | 2022-02-16 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 617-652 MHz | 0.087 | Amp | G7W | 27 |
| 617-652 MHz | 0.086 | Amp | G7W | 27 |
| 862-869 MHz | 0.086 | Amp | F9W | 90S |
| 862-869 MHz | 0.079 | Amp | F9W | 90S |
| 862-869 MHz | 0.08 | Amp | G7W | 90S |
| 869-894 MHz | 0.087 | Amp | G7W | 22H |
| 869-894 MHz | 0.087 | Amp | F9W | 22H |
| 869-894 MHz | 0.08 | Amp | F9W | 22H |
| 869-894 MHz | 0.088 | Amp | G7W | 22H |
| 2350-2360 MHz | 0.208 | Amp | G7W | 27 |
| 2350-2360 MHz | 0.182 | Amp | G7W | 27 |
Grants
TCB Grant - Application JLtDK7b/ldkhKANe/jp3Dw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 02/16/2022 Application Dated: 02/16/2022 |
| SOLiD, Inc. |
| 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, |
| Bundang-gu, |
| Seongnam-si, Gyeonggi-do, 463-400 South Korea |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UERA682335R |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | DAS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 617.0 - 652.0 | 0.095 | Amp | G7W | |
| 27 | 617.0 - 652.0 | 0.087 | Amp | G7W | |
| 27 | 617.0 - 652.0 | 0.086 | Amp | G7W | |
| 90S | 862.0 - 869.0 | 0.086 | Amp | F9W | |
| 90S | 862.0 - 869.0 | 0.079 | Amp | F9W | |
| 90S | 862.0 - 869.0 | 0.08 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 0.087 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.08 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.088 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 0.087 | Amp | G7W | |
| 27 | 2350.0 - 2360.0 | 0.208 | Amp | G7W | |
| 27 | 2350.0 - 2360.0 | 0.182 | Amp | G7W |
| In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.450 Watts on ANT1. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17dBi with minimum separation distance 60 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |
EAS Grant - Application JLtDK7b/ldkhKANe/jp3Dw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400 South Korea |
Date of Grant: 02/16/2022 Application Dated: 02/16/2022 |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UERA682335R |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | DAS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 617.0 - 652.0 | 0.095 | Amp | G7W | |
| 27 | 617.0 - 652.0 | 0.087 | Amp | G7W | |
| 27 | 617.0 - 652.0 | 0.086 | Amp | G7W | |
| 90S | 862.0 - 869.0 | 0.086 | Amp | F9W | |
| 90S | 862.0 - 869.0 | 0.079 | Amp | F9W | |
| 90S | 862.0 - 869.0 | 0.08 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 0.087 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.08 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.088 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 0.087 | Amp | G7W | |
| 27 | 2350.0 - 2360.0 | 0.208 | Amp | G7W | |
| 27 | 2350.0 - 2360.0 | 0.182 | Amp | G7W |
| In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.450 Watts on ANT1. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17dBi with minimum separation distance 60 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules. |