FCC ID W6UEROUA682335

DAS

by SOLiD, Inc.

Grantee Code: W6U   Product Code: EROUA682335
Latest application date: 2020-10-19

FCC ID Device Details

FCC IDW6UEROUA682335
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeW6U
Product CodeEROUA682335
Applicant BusinessSOLiD, Inc. 🇰🇷
Related Domains solid.co.kr
Equipment ClassDAS
Test FirmHCT Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
617-652 MHzOriginal Equipment2020-10-19

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-04-17PDF 1.3 MB
Internal PhotosInternal Photos2021-04-17PDF 654.5 KB
External PhotosExternal Photos2021-04-17PDF 811.9 KB
Label InfoID Label/Location Info2020-10-19PDF 322.1 KB
Test Setup PhotoTest Setup Photos2021-04-17PDF 993.9 KB
Test Report Part 1Test Report2020-10-19PDF 5.3 MB
Test Report Part 2Test Report2020-10-19PDF 4.1 MB
Attestation LetterAttestation Statements2020-10-19PDF 552.2 KB
Agent Authorization LetterCover Letter(s)2020-10-19PDF 363.2 KB
Confidentiality Request LetterCover Letter(s)2020-10-19PDF 456.8 KB
RF Exposure ReportRF Exposure Info2020-10-19PDF 418.6 KB
Block Diagram Metadata onlyBlock DiagramPDF 377.9 KB
Schematics Metadata onlySchematicsPDF 641.4 KB
Operational Description Metadata onlyOperational DescriptionPDF 286.6 KB
Part List Metadata onlyParts List/Tune Up InfoPDF 34.2 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 377.1 KB

Application Information

Application IDlfA/l4Kesl7XQ6E0qEhOPA==
Final Action Date2020-10-19
Application PurposeOriginal Equipment
Applicant FRN0018550988
ModelEROUA682335
Frequency Range617-652 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionDAS
Responsible PartyYong Chul Kim, Team Manager, yckim@solid.co.kr , +82-31-627-6292
Test FirmLee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr , 82-31-645-6432
TCB EmailTCB@hctamerica.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date04/17/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsIn-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.450 Watts. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17 dBi with minimum separation distance 120 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules.

Applications

Application IDDatePurpose
lfA/l4Kesl7XQ6E0qEhOPA==2020-10-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
617-652 MHz0.083AmpG7W27
617-652 MHz0.08AmpG7W27
862-869 MHz0.084AmpF9W90S
862-869 MHz0.086AmpF9W90S
862-869 MHz0.084AmpG7W90S
869-894 MHz0.091AmpG7W22H
869-894 MHz0.082AmpF9W22H
869-894 MHz0.079AmpF9W22H
869-894 MHz0.079AmpG7W22H
2350-2360 MHz0.214AmpG7W27
2350-2360 MHz0.211AmpG7W27

Grants

TCB Grant - Application lfA/l4Kesl7XQ6E0qEhOPA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 10/19/2020

Application Dated: 10/19/2020
SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220,
Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UEROUA682335
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: DAS
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 617.0  -  652.0 0.078  Amp G7W
27 617.0  -  652.0 0.083  Amp G7W
27 617.0  -  652.0 0.08  Amp G7W
90S 862.0  -  869.0 0.084  Amp F9W
90S 862.0  -  869.0 0.086  Amp F9W
90S 862.0  -  869.0 0.084  Amp G7W
22H 869.0  -  894.0 0.082  Amp F9W
22H 869.0  -  894.0 0.079  Amp F9W
22H 869.0  -  894.0 0.079  Amp G7W
22H 869.0  -  894.0 0.091  Amp G7W
27 2350.0  -  2360.0 0.214  Amp G7W
27 2350.0  -  2360.0 0.211  Amp G7W

In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.450 Watts. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17 dBi with minimum separation distance 120 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules.

EAS Grant - Application lfA/l4Kesl7XQ6E0qEhOPA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
  Date of Grant: 10/19/2020

Application Dated: 10/19/2020
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UEROUA682335
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: DAS
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 617.0  -  652.0 0.078  Amp G7W
27 617.0  -  652.0 0.083  Amp G7W
27 617.0  -  652.0 0.08  Amp G7W
90S 862.0  -  869.0 0.084  Amp F9W
90S 862.0  -  869.0 0.086  Amp F9W
90S 862.0  -  869.0 0.084  Amp G7W
22H 869.0  -  894.0 0.082  Amp F9W
22H 869.0  -  894.0 0.079  Amp F9W
22H 869.0  -  894.0 0.079  Amp G7W
22H 869.0  -  894.0 0.091  Amp G7W
27 2350.0  -  2360.0 0.214  Amp G7W
27 2350.0  -  2360.0 0.211  Amp G7W

In-Building DAS Industrial Booster. Power output listed is conducted. The device is capable of transmitting multiple signals in different bands at the same time with maximum combined conducted power of 0.450 Watts. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. The antenna used for this transmitter is to be fixed-mounted on indoor structures. The single unit RF Exposure compliance for the device was based on maximum antenna gain 17 dBi with minimum separation distance 120 cm. RF exposure compliance must need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b) (3) of the rules.



Mail To: