FCC ID W6UHM25TDDM

Alliance_5W

by SOLiD, Inc.

Grantee Code: W6U   Product Code: HM25TDDM
Latest application date: 2017-06-12

FCC ID Device Details

FCC IDW6UHM25TDDM
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeW6U
Product CodeHM25TDDM
Applicant BusinessSOLiD, Inc. 🇰🇷
Related Domains solid.co.kr
Equipment ClassAlliance_5W
Test FirmHCT Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2496.8-2690 MHzOriginal Equipment2017-06-12

Exhibits

DocumentTypeAvailableFile
Alliance 5W Users manual_170607Users Manual2017-12-09PDF 2.4 MB
MRDU_2500_60TDD_M_Internal PhotosInternal Photos2017-12-09PDF 1.6 MB
MRDU_2500_60TDD_M_External PhotosExternal Photos2017-12-09PDF 352.3 KB
MRDU_2500_60TDD_M_ID LabelID Label/Location Info2017-06-12PDF 545.4 KB
MRDU_2500_60TDD_M_Test Setup PhotoTest Setup Photos2017-12-09PDF 498.7 KB
MRDU_2500_60TDD_M_Test Report_Rev01Test Report2017-06-12PDF 2.4 MB
FCC_W6UHM25TDDM_Attestation letter for Warning Label Message_Part20Cover Letter(s)2017-06-12PDF 28.7 KB
FCC_W6UHM25TDDM_Agent Authorization LetterCover Letter(s)2017-06-12PDF 44.8 KB
FCC_W6UHM25TDDM_Confidentiality Request LetterCover Letter(s)2017-06-12PDF 52.1 KB
MRDU_2500_60TDD_M_Block diagram_Rev.1 Metadata onlyBlock DiagramPDF 113.7 KB
MRDU_2500_60TDD_M_Circuit Diagram Metadata onlySchematicsPDF 651.4 KB
Alliance 5W Operational description_170607 Metadata onlyOperational DescriptionPDF 570.6 KB
Alliance 5W Tune-up procedure(170413) Metadata onlyParts List/Tune Up InfoPDF 291.9 KB
MRDU_2500_60TDD_M_Part List Metadata onlyParts List/Tune Up InfoPDF 88.5 KB

Application Information

Application ID8/GXB1FB276QkWvY937PKw==
Final Action Date2017-06-12
Application PurposeOriginal Equipment
Applicant FRN0018550988
ModelHM25TDDM
Frequency Range2496.8-2690 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionAlliance_5W
Responsible PartyYong Chul Kim, Team Manager, yckim@solid.co.kr , +82-31-627-6292
Test FirmLee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr , 82-31-645-6432
TCB Emailtcb@hctamerica.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/09/2017
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is conducted. Device supports LTE 20MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

Applications

Application IDDatePurpose
8/GXB1FB276QkWvY937PKw==2017-06-12Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
2496.8-2690 MHz5.0350000AmpG7D27

Grants

TCB Grant - Application 8/GXB1FB276QkWvY937PKw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 06/12/2017

Application Dated: 06/10/2017
SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220,
Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UHM25TDDM
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Alliance_5W
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2496.8  -  2690.0 5.035  Amp G7D

Output power is conducted. Device supports LTE 20MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

EAS Grant - Application 8/GXB1FB276QkWvY937PKw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
  Date of Grant: 06/12/2017

Application Dated: 06/10/2017
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UHM25TDDM
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Alliance_5W
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 2496.8  -  2690.0 5.035  Amp G7D

Output power is conducted. Device supports LTE 20MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.



Mail To: