FCC ID W6UHM700LFN

ALLIANCE_5W

by SOLiD, Inc.

Grantee Code: W6U   Product Code: HM700LFN
Latest application date: 2017-08-04

FCC ID Device Details

FCC IDW6UHM700LFN
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeW6U
Product CodeHM700LFN
Applicant BusinessSOLiD, Inc. 🇰🇷
Related Domains solid.co.kr
Equipment ClassALLIANCE_5W
Test FirmHCT Co., LTD

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
728-757 MHzOriginal Equipment2017-08-04
758-768 MHzOriginal Equipment2017-08-04

Exhibits

DocumentTypeAvailableFile
Alliance 5W Users manual_Rev.1_170709Users Manual2018-01-31PDF 2.4 MB
MRDU_700LTE_FN_Internal PhotosInternal Photos2018-01-31PDF 1.5 MB
MRDU_700LTE_FN_External PhotosExternal Photos2018-01-31PDF 331 KB
MRDU_700LTE_FN_ID Label_Rev.1ID Label/Location Info2017-08-04PDF 433.7 KB
MRDU_700LTE_FN_Test Setup PhotoTest Setup Photos2018-01-31PDF 499 KB
MRDU_700LTE_FN_Test Report_Rev01Test Report2017-08-04PDF 3.8 MB
FCC_W6UHM700LFN_Attestation letter for Warning Label Message_Part20Cover Letter(s)2017-08-04PDF 28.6 KB
FCC_W6UHM700LFN_Attestation letter for Warning Label Message_Part90Cover Letter(s)2017-08-04PDF 28.6 KB
FCC_W6UHM700LFN_Agent Authorization LetterCover Letter(s)2017-08-04PDF 44.8 KB
FCC_W6UHM700LFN_Confidentiality Request LetterCover Letter(s)2017-08-04PDF 52 KB
MRDU_700LTE_FN_Block Diagram Metadata onlyBlock DiagramPDF 228.5 KB
MRDU_700LTE_FN_Circuit Diagram Metadata onlySchematicsPDF 342.2 KB
Alliance 5W Operational description(170615) Metadata onlyOperational DescriptionPDF 505.1 KB
Alliance 5W Tune-up procedure(170413) Metadata onlyParts List/Tune Up InfoPDF 291.9 KB
MRDU_700LTE_FN_Part List Metadata onlyParts List/Tune Up InfoPDF 356 KB

Application Information

Application IDsRpaw7c0hHtvzLgkwmXvcw==
Final Action Date2017-08-04
Application PurposeOriginal Equipment
Applicant FRN0018550988
ModelHM700LFN
Frequency Range728-757 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionALLIANCE_5W
Responsible PartyYong Chul Kim, Team Manager, yckim@solid.co.kr , +82-31-627-6292
Test FirmSang Lee, HCT Co., LTD, sjlee@HCT.co.kr , 82-31-645-6420
TCB Emailtcb@hctamerica.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date01/31/2018
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsIn-Building DAS Booster. Output power is conducted. Device supports LTE 5 MHz and 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

Applications

Application IDDatePurpose
sRpaw7c0hHtvzLgkwmXvcw==2017-08-04Original Equipment
Aa+sLNu/nQ9sEgYD4T5qdw==2017-08-04Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
728-757 MHz5.0580000AmpG7W27
758-768 MHz5.0120000AmpG7W90PF

Grants

TCB Grant - Application sRpaw7c0hHtvzLgkwmXvcw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 08/04/2017

Application Dated: 08/04/2017
SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220,
Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UHM700LFN
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: ALLIANCE_5W
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 728.0  -  757.0 5.058  Amp G7W

In-Building DAS Booster. Output power is conducted. Device supports LTE 5 MHz and 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

EAS Grant - Application sRpaw7c0hHtvzLgkwmXvcw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
  Date of Grant: 08/04/2017

Application Dated: 08/04/2017
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UHM700LFN
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: ALLIANCE_5W
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
27 728.0  -  757.0 5.058  Amp G7W

In-Building DAS Booster. Output power is conducted. Device supports LTE 5 MHz and 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.



TCB Grant - Application Aa+sLNu/nQ9sEgYD4T5qdw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  HCT America LLC
1726 Ringwood Avenue
San Jose, CA 95131
Date of Grant: 08/04/2017

Application Dated: 08/04/2017
SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220,
Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UHM700LFN
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: Alliance 5W
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
PF 90 758.0  -  768.0 5.012  Amp G7W

In-Building DAS Booster. Power output listed is conducted. Class B Booster is fix location installation only according to §90.219(d)(4). Device supports LTE 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

PF: Transmitter approved for Public Safety Broadband

EAS Grant - Application Aa+sLNu/nQ9sEgYD4T5qdw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SOLiD, Inc.
10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu,
Seongnam-si, Gyeonggi-do, 463-400
South Korea
  Date of Grant: 08/04/2017

Application Dated: 08/04/2017
 
Attention: Yong Chul Kim , Team Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  W6UHM700LFN
Name of Grantee:  SOLiD, Inc.
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: Alliance 5W
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
PF 90 758.0  -  768.0 5.012  Amp G7W

In-Building DAS Booster. Power output listed is conducted. Class B Booster is fix location installation only according to §90.219(d)(4). Device supports LTE 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.


PF: Transmitter approved for Public Safety Broadband

Mail To: