FCC ID W6UHMAWS13R
ALLIANCE_5W
by SOLiD, Inc.
Grantee Code: W6U Product Code: HMAWS13R
Latest application date: 2018-07-11
FCC ID Device Details
| FCC ID | W6UHMAWS13R |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | W6U |
| Product Code | HMAWS13R |
| Applicant Business | SOLiD, Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | ALLIANCE_5W |
| Test Firm | HCT Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2110-2180 MHz | Original Equipment | 2018-07-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| MRDU_AWS13_Users manual_20180705 | Users Manual | 2019-01-07 | PDF 1.8 MB |
| MRDU_AWS13 Internal Photos | Internal Photos | 2019-01-07 | PDF 395.1 KB |
| MRDU_AWS13 External Photos | External Photos | 2019-01-07 | PDF 229.3 KB |
| MRDU_AWS13_FCC_IC label & location_rev.1 | ID Label/Location Info | 2018-07-11 | PDF 384 KB |
| MRDU_AWS13 APPENDIX A_EUT and Test Setup Photo | Test Setup Photos | 2019-01-07 | PDF 180.6 KB |
| MRDU_AWS13 Test report_Rev01_part1 | Test Report | 2018-07-11 | PDF 2.5 MB |
| MRDU_AWS13 Test report_Rev01_part2 | Test Report | 2018-07-11 | PDF 4.4 MB |
| MRDU_AWS13 Test report_Rev01_part3 | Test Report | 2018-07-11 | PDF 3.6 MB |
| W6UHMAWS13R_Attestation letter for Warning Label Message_Part 20 | Cover Letter(s) | 2018-07-11 | PDF 57.4 KB |
| W6UHMAWS13R_Agent Authorization Letter.pdf | Cover Letter(s) | 2018-07-11 | PDF 70.8 KB |
| W6UHMAWS13R_Confidentiality Request Letter.pdf | Cover Letter(s) | 2018-07-11 | PDF 103 KB |
| MRDU_AWS13_Block diagram_rev.1 Metadata only | Block Diagram | PDF 142.5 KB | |
| MRDU_AWS13_Block diagram_rev.2 Metadata only | Block Diagram | PDF 160.9 KB | |
| MRDU_AWS13_Circuit Diagram Metadata only | Schematics | PDF 1.1 MB | |
| MRDU_AWS13_Operational description(180705) Metadata only | Operational Description | PDF 878.1 KB | |
| MRDU_AWS13_Part list Metadata only | Parts List/Tune Up Info | PDF 212.9 KB | |
| MRDU_AWS13_Tune-up procedure (180627) Metadata only | Parts List/Tune Up Info | PDF 425.7 KB |
Application Information
| Application ID | HUW2YG3Fj5D7x44+5Kw+pg== |
|---|---|
| Final Action Date | 2018-07-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018550988 |
| Model | HMAWS13R |
| Frequency Range | 2110-2180 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | ALLIANCE_5W |
| Responsible Party | Yong Chul Kim, Team Manager, yckim@solid.co.kr |
| Test Firm | Lee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr |
| TCB Email | tcb@hctamerica.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/07/2019 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | In-Building DAS booster. Output power is conducted. Device supports CDMA, WCDMA, and LTE 5/10MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| HUW2YG3Fj5D7x44+5Kw+pg== | 2018-07-11 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application HUW2YG3Fj5D7x44+5Kw+pg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 07/11/2018 Application Dated: 07/10/2018 |
| SOLiD, Inc. |
| 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, |
| Bundang-gu, |
| Seongnam-si, Gyeonggi-do, 463-400 South Korea |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UHMAWS13R |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ALLIANCE_5W |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 2110.0 - 2180.0 | 5.176 | Amp | G7W | |
| 27 | 2110.0 - 2180.0 | 5.284 | Amp | G7W | |
| 27 | 2110.0 - 2180.0 | 5.236 | Amp | G7W | |
| 27 | 2110.0 - 2180.0 | 5.346 | Amp | F9W |
| In-Building DAS booster. Output power is conducted. Device supports CDMA, WCDMA, and LTE 5/10MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
EAS Grant - Application HUW2YG3Fj5D7x44+5Kw+pg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400 South Korea |
Date of Grant: 07/11/2018 Application Dated: 07/10/2018 |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UHMAWS13R |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ALLIANCE_5W |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 2110.0 - 2180.0 | 5.176 | Amp | G7W | |
| 27 | 2110.0 - 2180.0 | 5.284 | Amp | G7W | |
| 27 | 2110.0 - 2180.0 | 5.236 | Amp | G7W | |
| 27 | 2110.0 - 2180.0 | 5.346 | Amp | F9W |
| In-Building DAS booster. Output power is conducted. Device supports CDMA, WCDMA, and LTE 5/10MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
| Mail To: |